Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -679,6 +679,7 @@ 679 679 )))|(% style="width:86px" %)Unix Time Stamp 680 680 681 681 682 + 682 682 IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status: 683 683 684 684 [[image:image-20250117104847-4.png]] ... ... @@ -784,9 +784,13 @@ 784 784 785 785 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 786 786 |(% style="background-color:#4f81bd; color:white; width:97px" %)((( 788 + 789 + 787 787 Size(bytes) 788 788 )))|(% style="background-color:#4f81bd; color:white; width:48px" %)2|(% style="background-color:#4f81bd; color:white; width:71px" %)2|(% style="background-color:#4f81bd; color:white; width:98px" %)2|(% style="background-color:#4f81bd; color:white; width:73px" %)2|(% style="background-color:#4f81bd; color:white; width:122px" %)1 789 -|(% style="width:98px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)((( 792 +|(% style="width:97px" %)Value|(% style="width:48px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:71px" %)[[Probe Model>>||anchor="H2.3.4ProbeModel"]]|(% style="width:98px" %)[[0 ~~~~ 20mA value>>||anchor="H2.3.507E20mAvalue28IDC_IN29"]]|(% style="width:73px" %)[[0 ~~~~ 30v value>>||anchor="H2.3.607E30Vvalue28pinVDC_IN29"]]|(% style="width:122px" %)((( 793 + 794 + 790 790 [[IN1 &IN2 Interrupt flag>>||anchor="H2.3.7IN126IN226INTpin"]] & ROC_flag 791 791 ))) 792 792 ... ... @@ -852,7 +852,6 @@ 852 852 853 853 ==== 2.8.2.1 Wave alarm mode ==== 854 854 855 - 856 856 Feature: By setting the detection period and a change value, the IDC/VDC variable is monitored whether it exceeds the set change value. If this change value is exceeded, the ROC uplink is sent and the comparison value is flushed. 857 857 858 858 * Change value: The amount by which the next detection value increases/decreases relative to the previous detection value. ... ... @@ -863,27 +863,46 @@ 863 863 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 864 864 |=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 154px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 197px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 865 865 |(% style="width:143px" %)AT+ROC=?|(% style="width:154px" %)Show current ROC setting|(% style="width:197px" %)((( 870 + 871 + 866 866 0,0,0,0(default) 867 867 OK 868 868 ))) 869 869 |(% colspan="1" rowspan="4" style="width:143px" %)((( 876 + 877 + 878 + 879 + 880 + 870 870 AT+ROC=a,b,c,d 871 871 )))|(% style="width:154px" %)((( 872 -**a:** Enable or disable the ROC 883 + 884 + 885 + 886 + 887 + 888 + 889 + 890 +a: Enable or disable the ROC 873 873 )))|(% style="width:197px" %)((( 874 -**0:** off 875 -**1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 -**2:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 892 + 893 + 894 +0: off 895 +1: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 896 + 897 +2: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 877 877 ))) 878 -|(% style="width:154px" %)**b:** Set the detection interval|(% style="width:197px" %)((( 899 +|(% style="width:154px" %)b: Set the detection interval|(% style="width:197px" %)((( 900 + 901 + 879 879 Range: 0~~65535s 880 880 ))) 881 -|(% style="width:154px" %) **c:**Setting the IDC change value|(% style="width:197px" %)Unit: uA882 -|(% style="width:154px" %) **d:**Setting the VDC change value|(% style="width:197px" %)Unit: mV904 +|(% style="width:154px" %)c: Setting the IDC change value|(% style="width:197px" %)Unit: uA 905 +|(% style="width:154px" %)d: Setting the VDC change value|(% style="width:197px" %)Unit: mV 883 883 884 884 Example: 885 885 886 -* AT+ROC=0,0,0,0 909 +* AT+ROC=0,0,0,0 ~/~/The ROC function is not used. 887 887 * AT+ROC=1,60,3000, 500 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink, and the comparison value is refreshed. 888 888 * AT+ROC=1,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. 889 889 * AT+ROC=2,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. In addition, if the change in the IDC does not exceed 3mA, then the ROC uplink is not sent, and the comparison value is not refreshed by the ROC uplink packet. However, if the device TDC time arrives, or if the user manually sends packets, then the IDC comparison value is also refreshed. ... ... @@ -902,9 +902,9 @@ 902 902 903 903 Example: 904 904 905 -* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/ 906 -* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/ 907 -* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/ 928 +* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/Equal to AT+ROC=1,60,3000, 500 929 +* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=1,60,3000,0 930 +* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=2,60,3000,0 908 908 909 909 Screenshot of parsing example in TTN: 910 910 ... ... @@ -915,7 +915,6 @@ 915 915 916 916 ==== 2.8.2.2 Over-threshold alarm mode ==== 917 917 918 - 919 919 Feature: Monitors whether the IDC/VDC exceeds the threshold by setting the detection period and threshold. Alarm if the threshold is exceeded. 920 920 921 921 AT Command: AT+ROC=3,a,b,c,d,e ... ... @@ -923,6 +923,8 @@ 923 923 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 924 924 |=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 185px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 925 925 |(% style="width:143px" %)AT+ROC=?|(% style="width:160px" %)Show current ROC setting|(% style="width:185px" %)((( 948 + 949 + 926 926 0,0,0,0(default) 927 927 OK 928 928 ))) ... ... @@ -934,32 +934,44 @@ 934 934 935 935 AT+ROC=3,a,b,c,d,e 936 936 )))|(% style="width:160px" %)((( 937 -**a:** Set the detection interval 961 + 962 + 963 +a: Set the detection interval 938 938 )))|(% style="width:185px" %)((( 965 + 966 + 939 939 Range: 0~~65535s 940 940 ))) 941 -|(% style="width:160px" %) **b:**Set the IDC alarm trigger condition|(% style="width:185px" %)(((942 - **0:** Lessthan the set IDC threshold, Alarm969 +|(% style="width:160px" %)b: Set the IDC alarm trigger condition|(% style="width:185px" %)((( 970 + 943 943 944 -**1:** Greater than the set IDC threshold, Alarm 972 +0: Less than the set IDC threshold, Alarm 973 + 974 +1: Greater than the set IDC threshold, Alarm 945 945 ))) 946 946 |(% style="width:160px" %)((( 947 -**c: ** IDC alarm threshold 977 + 978 + 979 +c: IDC alarm threshold 948 948 )))|(% style="width:185px" %)((( 981 + 982 + 949 949 Unit: uA 950 950 ))) 951 -|(% style="width:160px" %) **d:**Set the VDC alarm trigger condition|(% style="width:185px" %)(((952 - **0:** Lessthan the set VDC threshold, Alarm985 +|(% style="width:160px" %)d: Set the VDC alarm trigger condition|(% style="width:185px" %)((( 986 + 953 953 954 -**1:** Greater than the set VDC threshold, Alarm 988 +0: Less than the set VDC threshold, Alarm 989 + 990 +1: Greater than the set VDC threshold, Alarm 955 955 ))) 956 -|(% style="width:160px" %) **e:**VDC alarm threshold|(% style="width:185px" %)Unit: mV992 +|(% style="width:160px" %)e: VDC alarm threshold|(% style="width:185px" %)Unit: mV 957 957 958 958 Example: 959 959 960 -* AT+ROC=3,60,0,3000,0,5000 ~/~/ 961 -* AT+ROC=3,180,1,3000,1,5000 ~/~/ 962 -* AT+ROC=3,300,0,3000,1,5000 ~/~/ 996 +* AT+ROC=3,60,0,3000,0,5000 ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 997 +* AT+ROC=3,180,1,3000,1,5000 ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 998 +* AT+ROC=3,300,0,3000,1,5000 ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 963 963 964 964 Downlink Command: 0x09 03 aa bb cc dd ee 965 965 ... ... @@ -978,9 +978,9 @@ 978 978 979 979 Example: 980 980 981 -* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/ 982 -* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/ 983 -* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/ 1017 +* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,0,5000 1018 +* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,1,3000,1,5000 1019 +* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,1,5000 984 984 985 985 Screenshot of parsing example in TTN: 986 986