Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -679,7 +679,6 @@ 679 679 )))|(% style="width:86px" %)Unix Time Stamp 680 680 681 681 682 - 683 683 IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status: 684 684 685 685 [[image:image-20250117104847-4.png]] ... ... @@ -853,6 +853,7 @@ 853 853 854 854 ==== 2.8.2.1 Wave alarm mode ==== 855 855 855 + 856 856 Feature: By setting the detection period and a change value, the IDC/VDC variable is monitored whether it exceeds the set change value. If this change value is exceeded, the ROC uplink is sent and the comparison value is flushed. 857 857 858 858 * Change value: The amount by which the next detection value increases/decreases relative to the previous detection value. ... ... @@ -861,7 +861,7 @@ 861 861 AT Command: AT+ROC 862 862 863 863 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 864 -|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 154px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 19 7px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation864 +|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 154px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 193px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 865 865 |(% style="width:143px" %)AT+ROC=?|(% style="width:154px" %)Show current ROC setting|(% style="width:197px" %)((( 866 866 0,0,0,0(default) 867 867 OK ... ... @@ -869,21 +869,21 @@ 869 869 |(% colspan="1" rowspan="4" style="width:143px" %)((( 870 870 AT+ROC=a,b,c,d 871 871 )))|(% style="width:154px" %)((( 872 -a: Enable or disable the ROC 872 +**a:** Enable or disable the ROC 873 873 )))|(% style="width:197px" %)((( 874 -0: off 875 -1: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 -2: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 874 +**0:** off 875 +**1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 +**2:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 877 877 ))) 878 -|(% style="width:154px" %)b: Set the detection interval|(% style="width:197px" %)((( 878 +|(% style="width:154px" %)**b:** Set the detection interval|(% style="width:197px" %)((( 879 879 Range: 0~~65535s 880 880 ))) 881 -|(% style="width:154px" %)c: Setting the IDC change value|(% style="width:197px" %)Unit: uA 882 -|(% style="width:154px" %)d: Setting the VDC change value|(% style="width:197px" %)Unit: mV 881 +|(% style="width:154px" %)**c:** Setting the IDC change value|(% style="width:197px" %)Unit: uA 882 +|(% style="width:154px" %)**d:** Setting the VDC change value|(% style="width:197px" %)Unit: mV 883 883 884 884 Example: 885 885 886 -* AT+ROC=0,0,0,0 ~/~/The ROC function is not used. 886 +* AT+ROC=0,0,0,0 ~/~/ The ROC function is not used. 887 887 * AT+ROC=1,60,3000, 500 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink, and the comparison value is refreshed. 888 888 * AT+ROC=1,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. 889 889 * AT+ROC=2,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. In addition, if the change in the IDC does not exceed 3mA, then the ROC uplink is not sent, and the comparison value is not refreshed by the ROC uplink packet. However, if the device TDC time arrives, or if the user manually sends packets, then the IDC comparison value is also refreshed. ... ... @@ -902,9 +902,9 @@ 902 902 903 903 Example: 904 904 905 -* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/Equal to AT+ROC=1,60,3000, 500 906 -* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=1,60,3000,0 907 -* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=2,60,3000,0 905 +* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/ Equal to AT+ROC=1,60,3000, 500 906 +* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=1,60,3000,0 907 +* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=2,60,3000,0 908 908 909 909 Screenshot of parsing example in TTN: 910 910 ... ... @@ -915,64 +915,44 @@ 915 915 916 916 ==== 2.8.2.2 Over-threshold alarm mode ==== 917 917 918 + 918 918 Feature: Monitors whether the IDC/VDC exceeds the threshold by setting the detection period and threshold. Alarm if the threshold is exceeded. 919 919 920 920 AT Command: AT+ROC=3,a,b,c,d,e 921 921 922 922 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 923 -|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 18 5px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation924 +|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 187px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 924 924 |(% style="width:143px" %)AT+ROC=?|(% style="width:160px" %)Show current ROC setting|(% style="width:185px" %)((( 925 - 926 - 927 927 0,0,0,0(default) 928 928 OK 929 929 ))) 930 930 |(% colspan="1" rowspan="5" style="width:143px" %)((( 931 - 932 - 933 - 934 - 935 - 936 936 AT+ROC=3,a,b,c,d,e 937 937 )))|(% style="width:160px" %)((( 938 - 939 - 940 -a: Set the detection interval 932 +**a:** Set the detection interval 941 941 )))|(% style="width:185px" %)((( 942 - 943 - 944 944 Range: 0~~65535s 945 945 ))) 946 -|(% style="width:160px" %)b: Set the IDC alarm trigger condition|(% style="width:185px" %)((( 947 - 948 - 949 -0: Less than the set IDC threshold, Alarm 950 - 951 -1: Greater than the set IDC threshold, Alarm 936 +|(% style="width:160px" %)**b:** Set the IDC alarm trigger condition|(% style="width:185px" %)((( 937 +**0:** Less than the set IDC threshold, Alarm 938 +**1:** Greater than the set IDC threshold, Alarm 952 952 ))) 953 953 |(% style="width:160px" %)((( 954 - 955 - 956 -c: IDC alarm threshold 941 +**c: ** IDC alarm threshold 957 957 )))|(% style="width:185px" %)((( 958 - 959 - 960 960 Unit: uA 961 961 ))) 962 -|(% style="width:160px" %)d: Set the VDC alarm trigger condition|(% style="width:185px" %)((( 963 - 964 - 965 -0: Less than the set VDC threshold, Alarm 966 - 967 -1: Greater than the set VDC threshold, Alarm 945 +|(% style="width:160px" %)**d:** Set the VDC alarm trigger condition|(% style="width:185px" %)((( 946 +**0:** Less than the set VDC threshold, Alarm 947 +**1:** Greater than the set VDC threshold, Alarm 968 968 ))) 969 -|(% style="width:160px" %)e: VDC alarm threshold|(% style="width:185px" %)Unit: mV 949 +|(% style="width:160px" %)**e:** VDC alarm threshold|(% style="width:185px" %)Unit: mV 970 970 971 971 Example: 972 972 973 -* AT+ROC=3,60,0,3000,0,5000 ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 974 -* AT+ROC=3,180,1,3000,1,5000 ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 975 -* AT+ROC=3,300,0,3000,1,5000 ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 953 +* AT+ROC=3,60,0,3000,0,5000 ~/~/ The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 954 +* AT+ROC=3,180,1,3000,1,5000 ~/~/ The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 955 +* AT+ROC=3,300,0,3000,1,5000 ~/~/ The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 976 976 977 977 Downlink Command: 0x09 03 aa bb cc dd ee 978 978 ... ... @@ -991,9 +991,9 @@ 991 991 992 992 Example: 993 993 994 -* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,0,5000 995 -* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,1,3000,1,5000 996 -* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,1,5000 974 +* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,0,5000 975 +* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,1,3000,1,5000 976 +* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,1,5000 997 997 998 998 Screenshot of parsing example in TTN: 999 999 ... ... @@ -1047,18 +1047,14 @@ 1047 1047 1048 1048 AT Command: AT+TDC 1049 1049 1050 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:510px" %)1030 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1051 1051 |=(% style="width: 160px; background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 160px; background-color:#4F81BD;color:white" %)Function|=(% style="width: 190px;background-color:#4F81BD;color:white" %)Response 1052 1052 |(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=?|(% style="background-color:#f2f2f2; width:166px" %)Show current transmit Interval|(% style="background-color:#f2f2f2" %)((( 1053 - 1054 - 1055 1055 30000 1056 1056 OK 1057 1057 the interval is 30000ms = 30s 1058 1058 ))) 1059 1059 |(% style="background-color:#f2f2f2; width:157px" %)AT+TDC=60000|(% style="background-color:#f2f2f2; width:166px" %)Set Transmit Interval|(% style="background-color:#f2f2f2" %)((( 1060 - 1061 - 1062 1062 OK 1063 1063 Set transmit interval to 60000ms = 60 seconds 1064 1064 ))) ... ... @@ -1079,18 +1079,14 @@ 1079 1079 1080 1080 AT Command: AT+INTMOD 1081 1081 1082 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:510px" %)1058 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1083 1083 |=(% style="width: 154px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 196px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 160px;background-color:#4F81BD;color:white" %)Response 1084 1084 |(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=?|(% style="background-color:#f2f2f2; width:196px" %)Show current interrupt mode|(% style="background-color:#f2f2f2; width:157px" %)((( 1085 - 1086 - 1087 1087 0 1088 1088 OK 1089 1089 the mode is 0 =Disable Interrupt 1090 1090 ))) 1091 1091 |(% style="background-color:#f2f2f2; width:154px" %)AT+INTMOD=2|(% style="background-color:#f2f2f2; width:196px" %)((( 1092 - 1093 - 1094 1094 Set Transmit Interval 1095 1095 0. (Disable Interrupt), 1096 1096 ~1. (Trigger by rising and falling edge) ... ... @@ -1114,72 +1114,52 @@ 1114 1114 1115 1115 AT Command: AT+3V3T 1116 1116 1117 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:474px" %)1089 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:474px" %) 1118 1118 |=(% style="width: 154px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 201px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 119px;background-color:#4F81BD;color:white" %)Response 1119 1119 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=?|(% style="background-color:#f2f2f2; width:201px" %)Show 3V3 open time.|(% style="background-color:#f2f2f2; width:116px" %)((( 1120 - 1121 - 1122 1122 0 1123 1123 OK 1124 1124 ))) 1125 1125 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=0|(% style="background-color:#f2f2f2; width:201px" %)Normally open 3V3 power supply.|(% style="background-color:#f2f2f2; width:116px" %)((( 1126 - 1127 - 1128 1128 OK 1129 1129 default setting 1130 1130 ))) 1131 1131 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=1000|(% style="background-color:#f2f2f2; width:201px" %)Close after a delay of 1000 milliseconds.|(% style="background-color:#f2f2f2; width:116px" %)((( 1132 - 1133 - 1134 1134 OK 1135 1135 ))) 1136 1136 |(% style="background-color:#f2f2f2; width:154px" %)AT+3V3T=65535|(% style="background-color:#f2f2f2; width:201px" %)Normally closed 3V3 power supply.|(% style="background-color:#f2f2f2; width:116px" %)((( 1137 - 1138 - 1139 1139 OK 1140 1140 ))) 1141 1141 1142 1142 AT Command: AT+5VT 1143 1143 1144 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:470px" %)1108 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:470px" %) 1145 1145 |=(% style="width: 155px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 196px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 119px;background-color:#4F81BD;color:white" %)Response 1146 1146 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=?|(% style="background-color:#f2f2f2; width:196px" %)Show 5V open time.|(% style="background-color:#f2f2f2; width:114px" %)((( 1147 - 1148 - 1149 1149 0 1150 1150 OK 1151 1151 ))) 1152 1152 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=0|(% style="background-color:#f2f2f2; width:196px" %)Normally closed 5V power supply.|(% style="background-color:#f2f2f2; width:114px" %)((( 1153 - 1154 - 1155 1155 OK 1156 1156 default setting 1157 1157 ))) 1158 1158 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=1000|(% style="background-color:#f2f2f2; width:196px" %)Close after a delay of 1000 milliseconds.|(% style="background-color:#f2f2f2; width:114px" %)((( 1159 - 1160 - 1161 1161 OK 1162 1162 ))) 1163 1163 |(% style="background-color:#f2f2f2; width:155px" %)AT+5VT=65535|(% style="background-color:#f2f2f2; width:196px" %)Normally open 5V power supply.|(% style="background-color:#f2f2f2; width:114px" %)((( 1164 - 1165 - 1166 1166 OK 1167 1167 ))) 1168 1168 1169 1169 AT Command: AT+12VT 1170 1170 1171 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:443px" %)1127 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:443px" %) 1172 1172 |=(% style="width: 156px;background-color:#4F81BD;color:white" %)Command Example|=(% style="width: 199px;background-color:#4F81BD;color:white" %)Function|=(% style="width: 88px;background-color:#4F81BD;color:white" %)Response 1173 1173 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=?|(% style="background-color:#f2f2f2; width:199px" %)Show 12V open time.|(% style="background-color:#f2f2f2; width:83px" %)((( 1174 - 1175 - 1176 1176 0 1177 1177 OK 1178 1178 ))) 1179 1179 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=0|(% style="background-color:#f2f2f2; width:199px" %)Normally closed 12V power supply.|(% style="background-color:#f2f2f2; width:83px" %)OK 1180 1180 |(% style="background-color:#f2f2f2; width:156px" %)AT+12VT=500|(% style="background-color:#f2f2f2; width:199px" %)Close after a delay of 500 milliseconds.|(% style="background-color:#f2f2f2; width:83px" %)((( 1181 - 1182 - 1183 1183 OK 1184 1184 ))) 1185 1185 ... ... @@ -1266,15 +1266,12 @@ 1266 1266 bb: Each collection interval (s), the value is 1~~65535 1267 1267 cc: the number of collection times, the value is 1~~120 1268 1268 1269 -(% border="1" cellspacing=" 4" style="background-color:#f2f2f2; width:510px" %)1221 +(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 1270 1270 |(% style="background-color:#4f81bd; color:white; width:160px" %)Command Example|(% style="background-color:#4f81bd; color:white; width:215px" %)Function|(% style="background-color:#4f81bd; color:white" %)Response 1271 1271 |(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=?|(% style="background-color:#f2f2f2; width:215px" %)Get the mode of multiple acquisitions and one uplink.|(% style="background-color:#f2f2f2" %)1,10,18 1272 1272 OK 1273 1273 |(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=1,10,18|(% style="background-color:#f2f2f2; width:215px" %)Set the mode of multiple acquisitions and one uplink, collect once every 10 seconds, and report after 18 times.|(% style="background-color:#f2f2f2" %)((( 1274 - 1275 - 1276 1276 Attention:Take effect after ATZ 1277 - 1278 1278 OK 1279 1279 ))) 1280 1280 |(% style="background-color:#f2f2f2; width:160px" %)AT+STDC=0, 0,0|(% style="background-color:#f2f2f2; width:215px" %)((( ... ... @@ -1284,10 +1284,7 @@ 1284 1284 1285 1285 1286 1286 )))|(% style="background-color:#f2f2f2" %)((( 1287 - 1288 - 1289 1289 Attention:Take effect after ATZ 1290 - 1291 1291 OK 1292 1292 ))) 1293 1293