Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -679,7 +679,6 @@ 679 679 )))|(% style="width:86px" %)Unix Time Stamp 680 680 681 681 682 - 683 683 IN1_pin_level & IN2_pin_level & Exti_pin_level & Exti_status: 684 684 685 685 [[image:image-20250117104847-4.png]] ... ... @@ -853,6 +853,7 @@ 853 853 854 854 ==== 2.8.2.1 Wave alarm mode ==== 855 855 855 + 856 856 Feature: By setting the detection period and a change value, the IDC/VDC variable is monitored whether it exceeds the set change value. If this change value is exceeded, the ROC uplink is sent and the comparison value is flushed. 857 857 858 858 * Change value: The amount by which the next detection value increases/decreases relative to the previous detection value. ... ... @@ -869,21 +869,21 @@ 869 869 |(% colspan="1" rowspan="4" style="width:143px" %)((( 870 870 AT+ROC=a,b,c,d 871 871 )))|(% style="width:154px" %)((( 872 -a: Enable or disable the ROC 872 +**a:** Enable or disable the ROC 873 873 )))|(% style="width:197px" %)((( 874 -0: off 875 -1: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 -2: Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 874 +**0:** off 875 +**1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 876 +**2:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.7Button26LEDs"]]). 877 877 ))) 878 -|(% style="width:154px" %)b: Set the detection interval|(% style="width:197px" %)((( 878 +|(% style="width:154px" %)**b:** Set the detection interval|(% style="width:197px" %)((( 879 879 Range: 0~~65535s 880 880 ))) 881 -|(% style="width:154px" %)c: Setting the IDC change value|(% style="width:197px" %)Unit: uA 882 -|(% style="width:154px" %)d: Setting the VDC change value|(% style="width:197px" %)Unit: mV 881 +|(% style="width:154px" %)**c:** Setting the IDC change value|(% style="width:197px" %)Unit: uA 882 +|(% style="width:154px" %)**d:** Setting the VDC change value|(% style="width:197px" %)Unit: mV 883 883 884 884 Example: 885 885 886 -* AT+ROC=0,0,0,0 ~/~/The ROC function is not used. 886 +* AT+ROC=0,0,0,0 ~/~/ The ROC function is not used. 887 887 * AT+ROC=1,60,3000, 500 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink, and the comparison value is refreshed. 888 888 * AT+ROC=1,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. 889 889 * AT+ROC=2,60,3000,0 ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. In addition, if the change in the IDC does not exceed 3mA, then the ROC uplink is not sent, and the comparison value is not refreshed by the ROC uplink packet. However, if the device TDC time arrives, or if the user manually sends packets, then the IDC comparison value is also refreshed. ... ... @@ -902,9 +902,9 @@ 902 902 903 903 Example: 904 904 905 -* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/Equal to AT+ROC=1,60,3000, 500 906 -* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=1,60,3000,0 907 -* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/Equal to AT+ROC=2,60,3000,0 905 +* Downlink Payload: 09 01 00 3C 0B B8 01 F4 ~/~/ Equal to AT+ROC=1,60,3000, 500 906 +* Downlink Payload: 09 01 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=1,60,3000,0 907 +* Downlink Payload: 09 02 00 3C 0B B8 00 00 ~/~/ Equal to AT+ROC=2,60,3000,0 908 908 909 909 Screenshot of parsing example in TTN: 910 910 ... ... @@ -915,6 +915,7 @@ 915 915 916 916 ==== 2.8.2.2 Over-threshold alarm mode ==== 917 917 918 + 918 918 Feature: Monitors whether the IDC/VDC exceeds the threshold by setting the detection period and threshold. Alarm if the threshold is exceeded. 919 919 920 920 AT Command: AT+ROC=3,a,b,c,d,e ... ... @@ -922,57 +922,36 @@ 922 922 (% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %) 923 923 |=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)Command Example|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)Parameters|=(% style="width: 185px; background-color: rgb(79, 129, 189); color: white;" %)Response/Explanation 924 924 |(% style="width:143px" %)AT+ROC=?|(% style="width:160px" %)Show current ROC setting|(% style="width:185px" %)((( 925 - 926 - 927 927 0,0,0,0(default) 928 928 OK 929 929 ))) 930 930 |(% colspan="1" rowspan="5" style="width:143px" %)((( 931 - 932 - 933 - 934 - 935 - 936 936 AT+ROC=3,a,b,c,d,e 937 937 )))|(% style="width:160px" %)((( 938 - 939 - 940 -a: Set the detection interval 932 +**a:** Set the detection interval 941 941 )))|(% style="width:185px" %)((( 942 - 943 - 944 944 Range: 0~~65535s 945 945 ))) 946 -|(% style="width:160px" %)b: Set the IDC alarm trigger condition|(% style="width:185px" %)((( 947 - 948 - 949 -0: Less than the set IDC threshold, Alarm 950 - 951 -1: Greater than the set IDC threshold, Alarm 936 +|(% style="width:160px" %)**b:** Set the IDC alarm trigger condition|(% style="width:185px" %)((( 937 +**0:** Less than the set IDC threshold, Alarm 938 +**1:** Greater than the set IDC threshold, Alarm 952 952 ))) 953 953 |(% style="width:160px" %)((( 954 - 955 - 956 -c: IDC alarm threshold 941 +**c: ** IDC alarm threshold 957 957 )))|(% style="width:185px" %)((( 958 - 959 - 960 960 Unit: uA 961 961 ))) 962 -|(% style="width:160px" %)d: Set the VDC alarm trigger condition|(% style="width:185px" %)((( 963 - 964 - 965 -0: Less than the set VDC threshold, Alarm 966 - 967 -1: Greater than the set VDC threshold, Alarm 945 +|(% style="width:160px" %)**d:** Set the VDC alarm trigger condition|(% style="width:185px" %)((( 946 +**0:** Less than the set VDC threshold, Alarm 947 +**1:** Greater than the set VDC threshold, Alarm 968 968 ))) 969 -|(% style="width:160px" %)e: VDC alarm threshold|(% style="width:185px" %)Unit: mV 949 +|(% style="width:160px" %)**e:** VDC alarm threshold|(% style="width:185px" %)Unit: mV 970 970 971 971 Example: 972 972 973 -* AT+ROC=3,60,0,3000,0,5000 ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 974 -* AT+ROC=3,180,1,3000,1,5000 ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 975 -* AT+ROC=3,300,0,3000,1,5000 ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 953 +* AT+ROC=3,60,0,3000,0,5000 ~/~/ The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated. 954 +* AT+ROC=3,180,1,3000,1,5000 ~/~/ The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated. 955 +* AT+ROC=3,300,0,3000,1,5000 ~/~/ The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated. 976 976 977 977 Downlink Command: 0x09 03 aa bb cc dd ee 978 978 ... ... @@ -991,9 +991,9 @@ 991 991 992 992 Example: 993 993 994 -* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,0,5000 995 -* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,1,3000,1,5000 996 -* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/Equal to AT+ROC=3,60,0,3000,1,5000 974 +* Downlink Payload: 09 03 00 3C 00 0B B8 00 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,0,5000 975 +* Downlink Payload: 09 03 00 b4 01 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,1,3000,1,5000 976 +* Downlink Payload: 09 03 01 2C 00 0B B8 01 13 38 ~/~/ Equal to AT+ROC=3,60,0,3000,1,5000 997 997 998 998 Screenshot of parsing example in TTN: 999 999