Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/27 10:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -662,7 +662,7 @@ 662 662 )))|(% style="width:104px" %)((( 663 663 VDC 664 664 665 -_intput_V 665 +_intput_mV 666 666 )))|(% style="width:83px" %)((( 667 667 IDC 668 668 ... ... @@ -731,7 +731,7 @@ 731 731 ))) 732 732 733 733 ((( 734 -**VDC_intput_V **= 0x0D10/1000=3.344V 734 +**VDC_intput_mV **= 0x0D10/1000=3.344mV 735 735 736 736 **IDC_intput_mA **= 0x0000/1000=0mA 737 737 ))) ... ... @@ -750,13 +750,7 @@ 750 750 **Unix time** is 0x6788DB63 = 1737022307s = 2025/1/16 10:11:47 751 751 ))) 752 752 753 -**Its data format is:** 754 754 755 -[Probe_mod, VDC_intput_V, IDC_intput_mA, IN1_pin_level**, **IN2_pin_level, Exti_pin_level, water_deep, Data_time],[Probe_mod, VDC_intput_V, IDC_intput_mA, IN1_pin_level**, **IN2_pin_level, Exti_pin_level, water_deep, Data_time],... 756 - 757 -(% style="color:red" %)**Note: water_deep in the data needs to be converted using decoding to get it.** 758 - 759 - 760 760 === 2.6.5 Decoder in TTN V3 === 761 761 762 762 [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652862574387-195.png?width=722&height=359&rev=1.1||alt="1652862574387-195.png" height="359" width="722"]]