Changes for page PS-LB/LS -- LoRaWAN Air Water Pressure Sensor User Manual
Last modified by Xiaoling on 2025/04/19 17:58
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -775,7 +775,7 @@ 775 775 **0:** off 776 776 **1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. 777 777 778 -**2: **Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1. 7Button26LEDs"]]).778 +**2: **Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.6Button26LEDs"]]). 779 779 ))) 780 780 |(% style="width:154px" %)**b**: Set the detection interval|(% style="width:197px" %)((( 781 781 Range: 0~~65535s ... ... @@ -843,23 +843,19 @@ 843 843 844 844 **1:** Greater than the set IDC threshold, Alarm 845 845 ))) 846 -|(% style="width:160px" %)((( 847 -**c**: IDC alarm threshold 848 -)))|(% style="width:185px" %)((( 849 -Unit: uA 850 -))) 851 -|(% style="width:160px" %)**d**: Set the VDC alarm trigger condition|(% style="width:185px" %)((( 846 +|(% style="width:160px" %)**c**: Set the VDC alarm trigger condition|(% style="width:185px" %)((( 852 852 **0:** Less than the set VDC threshold, Alarm 853 853 854 854 **1:** Greater than the set VDC threshold, Alarm 855 855 ))) 851 +|(% style="width:160px" %)**d**: IDC alarm threshold|(% style="width:185px" %)Unit: uA 856 856 |(% style="width:160px" %)**e:** VDC alarm threshold|(% style="width:185px" %)Unit: mV 857 857 858 858 **Example:** 859 859 860 -* AT+ROC=3,60,0,3000, 0,5000~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 5000mV, an alarm is generated.861 -* AT+ROC=3,180,1,3000, 1,5000~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 5000mV, an alarm is generated.862 -* AT+ROC=3,300,0,3000, 1,5000~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 5000mV, an alarm is generated.856 +* AT+ROC=3,60,0,0,3000,500 ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 500mV, an alarm is generated. 857 +* AT+ROC=3,180,1,1,3000,500 ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 500mV, an alarm is generated. 858 +* AT+ROC=3,300,0,1,3000,500 ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 500mV, an alarm is generated. 863 863 864 864 (% style="color:blue" %)**Downlink Command: 0x09 03 aa bb cc dd ee** 865 865 ... ... @@ -869,26 +869,23 @@ 869 869 870 870 (% style="color:blue" %)**bb: **(% style="color:#037691" %)**1 byte; **(%%)Set the IDC alarm trigger condition. 871 871 872 -(% style="color:blue" %)**cc: **(% style="color:#037691" %)** 2bytes;**(%%)IDC alarm threshold.(uA)868 +(% style="color:blue" %)**cc: **(% style="color:#037691" %)**1 byte;**(%%) Set the VDC alarm trigger condition. 873 873 870 +(% style="color:blue" %)**dd: **(% style="color:#037691" %)**2 bytes;**(%%) IDC alarm threshold.(uA) 874 874 875 -(% style="color:blue" %)**dd: **(% style="color:#037691" %)**1 byte;**(%%) Set the VDC alarm trigger condition. 876 - 877 877 (% style="color:blue" %)**ee: **(% style="color:#037691" %)**2 bytes; **(%%)VDC alarm threshold.(mV) 878 878 879 879 **Example:** 880 880 881 -* Downlink Payload: **09 03 00 3C 00 01338** ~/~/Equal to AT+ROC=3,60,0,3000,0,5000882 -* Downlink Payload: **09 03 00 b4 01 13 38** ~/~/Equal to AT+ROC=3,60,1,3000,1,5000883 -* Downlink Payload: **09 03 01 2C 00 0B B8 01 13 38**60,0,3000,1,5000876 +* Downlink Payload: **09 03 00 3C 00 00 0B B8 01 F4** ~/~/Equal to AT+ROC=3,60,0,0,3000,500 877 +* Downlink Payload: **09 03 00 b4 01 01 0B B8 01 F4** ~/~/Equal to AT+ROC=3,180,1,1,3000,500 878 +* Downlink Payload: **09 03 01 2C 00 01 0B B8 01 F4** ~/~/Equal to AT+ROC=3,300,0,1,3000,500 884 884 885 885 (% style="color:blue" %)**Screenshot of parsing example in TTN:** 886 886 887 -* AT+ROC=3,60,0,3000,0,5000 888 888 889 889 890 890 891 - 892 892 == 2.9 Firmware Change Log == 893 893 894 894