From version < 103.1 >
edited by Mengting Qiu
on 2025/01/16 16:32
To version < 99.2 >
edited by Xiaoling
on 2024/10/21 09:32
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.ting
1 +XWiki.Xiaoling
Content
... ... @@ -593,7 +593,7 @@
593 593  === 2.6.1 Unix TimeStamp ===
594 594  
595 595  
596 -PS-LB uses Unix TimeStamp format based on
596 +CPL01 uses Unix TimeStamp format based on
597 597  
598 598  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652861618065-927.png?width=705&height=109&rev=1.1||alt="1652861618065-927.png" height="109" width="705"]]
599 599  
... ... @@ -647,7 +647,7 @@
647 647  
648 648  Is to check 2021/11/12 12:00:00 to 2021/11/12 15:00:00's data
649 649  
650 -Uplink Internal =5s,means PS-LB will send one packet every 5s. range 5~~255s.
650 +Uplink Internal =5s,means CPL01 will send one packet every 5s. range 5~~255s.
651 651  
652 652  
653 653  === 2.6.4 Decoder in TTN V3 ===
... ... @@ -665,7 +665,7 @@
665 665  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/a>>http://wiki.dragino.com/xwiki/bin/view/Main/End%20Device%20Frequency%20Band/]]
666 666  
667 667  
668 -== 2.8 Report on Change Feature (Since firmware V1.2) ==
668 +== 2.8 Report on Change Feature (Since firmware V1.1.2) ==
669 669  
670 670  === 2.8.1 Uplink payload(Enable ROC) ===
671 671  
... ... @@ -739,22 +739,14 @@
739 739  === 2.8.2 Set the Report on Change ===
740 740  
741 741  
742 -Feature: Get or Set the Report on Change.
743 -
744 -
745 -==== 2.8.2.1 Wave alarm mode ====
746 -
747 -Feature: By setting the detection period and a change value, the IDC/VDC variable is monitored whether it exceeds the set change value. If this change value is exceeded, the ROC uplink is sent and the comparison value is flushed.
748 -
749 -* (% style="color:#037691" %)**Change value: **(%%)The amount by which the next detection value increases/decreases relative to the previous detection value.
750 -* (% style="color:#037691" %)**Comparison value:**(%%) A parameter to compare with the latest ROC test.
751 -
742 +Feature: Set the detection interval and threshold to monitor whether the IDC/VDC variable exceeds the threshold. If the threshold is exceeded, an ROC uplink is sent.
752 752  (% style="color:blue" %)**AT Command: AT+ROC**
753 753  
754 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
755 -|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 154px; background-color: rgb(79, 129, 189); color: white;" %)**Parameters**|=(% style="width: 197px; background-color: rgb(79, 129, 189); color: white;" %)**Response/Explanation**
756 -|(% style="width:143px" %)AT+ROC=?|(% style="width:154px" %)Show current ROC setting|(% style="width:197px" %)(((
745 +(% border="1" cellspacing="4" style="background-color:#f2f2f2; width:510px" %)
746 +|=(% style="width: 143px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 197px; background-color: rgb(79, 129, 189); color: white;" %)**Parameters**|=(% style="width: 170px; background-color: rgb(79, 129, 189); color: white;" %)**Response/Explanation**
747 +|(% style="width:143px" %)AT+ROC=?|(% style="width:197px" %)Show current ROC setting|(% style="width:168px" %)(((
757 757  0,0,0,0(default)
749 +
758 758  OK
759 759  )))
760 760  |(% colspan="1" rowspan="4" style="width:143px" %)(((
... ... @@ -763,50 +763,36 @@
763 763  
764 764  
765 765  AT+ROC=a,b,c,d
766 -)))|(% style="width:154px" %)(((
767 -
758 +)))|(% style="width:197px" %)**a**: Enable or disable the ROC|(% style="width:168px" %)(((
759 +0: off
768 768  
769 -
770 -
771 -
772 -
773 -**a**: Enable or disable the ROC
774 -)))|(% style="width:197px" %)(((
775 -**0:** off
776 -**1:** Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value.
777 -
778 -**2: **Turn on the wave alarm mode, send the ROC uplink when the increment exceeds the set parameter and refresh the comparison value. In addition, the comparison value is refreshed when the device sends packets ([[TDC>>||anchor="H3.3.1SetTransmitIntervalTime"]] or [[ACT>>||anchor="H1.6Button26LEDs"]]).
761 +1: on
779 779  )))
780 -|(% style="width:154px" %)**b**: Set the detection interval|(% style="width:197px" %)(((
781 -Range:  0~~65535s
782 -)))
783 -|(% style="width:154px" %)**c**: Setting the IDC change value|(% style="width:197px" %)Unit: uA
784 -|(% style="width:154px" %)**d**: Setting the VDC change value|(% style="width:197px" %)Unit: mV
763 +|(% style="width:197px" %)**b**: Set the detection interval|(% style="width:168px" %)Unit: second
764 +|(% style="width:197px" %)**c**: Setting the IDC change threshold|(% style="width:168px" %)Unit: uA
765 +|(% style="width:197px" %)**d**: Setting the VDC change threshold|(% style="width:168px" %)Unit: mV
785 785  
786 786  **Example:**
787 787  
788 -* AT+ROC=0,0,0,0  ~/~/The ROC function is not used.
789 -* AT+ROC=1,60,3000, 500  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink, and the comparison value is refreshed.
790 -* AT+ROC=1,60,3000,0  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage.
791 -* AT+ROC=2,60,3000,0  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink and the comparison value of IDC is refreshed. dd=0 Means doesn't monitor Voltage. In addition, if the change in the IDC does not exceed 3mA, then the ROC uplink is not sent, and the comparison value is not refreshed by the ROC uplink packet. However, if the device TDC time arrives, or if the user manually sends packets, then the IDC comparison value is also refreshed.
769 +* AT+ROC=1,60,3000, 500  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA) or VDC (>500mV), sends an ROC uplink.
770 +* AT+ROC=1,60,3000,0  ~/~/ Check value every 60 seconds. lf there is change in IDC (>3mA), send an ROC uplink. 0 Means doesn't monitor Voltage.
792 792  
793 793  (% style="color:blue" %)**Downlink Command: 0x09 aa bb cc dd**
794 794  
795 795  Format: Function code (0x09) followed by 4 bytes.
796 796  
797 -(% style="color:blue" %)**aa: **(% style="color:#037691" %)**1 byte;**(%%) Set the wave alarm mode.
776 +(% style="color:blue" %)**aa: **(%%)Enable/Disable the ROC.
798 798  
799 -(% style="color:blue" %)**bb: **(% style="color:#037691" %)**2 bytes;**(%%) Set the detection interval. (second)
778 +(% style="color:blue" %)**bb: **(%%)Set the detection interval. (second)
800 800  
801 -(% style="color:blue" %)**cc: **(% style="color:#037691" %)**2 bytes;**(%%) Setting the IDC change threshold. (uA)
780 +(% style="color:blue" %)**cc: **(%%)Setting the IDC change threshold. (uA)
802 802  
803 -(% style="color:blue" %)**dd: **(% style="color:#037691" %)**2 bytes;**(%%) Setting the VDC change threshold. (mV)
782 +(% style="color:blue" %)**dd: **(%%)Setting the VDC change threshold. (mV)
804 804  
805 805  **Example:**
806 806  
807 -* Downlink Payload: **09 01 00 3C 0B B8 01 F4 ** ~/~/Equal to AT+ROC=1,60,3000, 500
808 -* Downlink Payload: **09 01 00 3C 0B B8 00 00 ** ~/~/Equal to AT+ROC=1,60,3000,0
809 -* Downlink Payload: **09 02 00 3C 0B B8 00 00 ** ~/~/Equal to AT+ROC=2,60,3000,0
786 +* Downlink Payload: **09 01 00 3C 0B B8 01 F4 ** ~/~/ Equal to AT+ROC=1,60,3000, 500
787 +* Downlink Payload: **09 01 00 3C 0B B8 00 00 ** ~/~/ AT+ROC=1,60,3000,0
810 810  
811 811  (% style="color:blue" %)**Screenshot of parsing example in TTN:**
812 812  
... ... @@ -815,73 +815,6 @@
815 815  [[image:https://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/PS-LB-NA--LoRaWAN_Analog_Sensor_User_Manual/WebHome/image-20241019170902-1.png?width=1454&height=450&rev=1.1||alt="image-20241019170902-1.png"]]
816 816  
817 817  
818 -==== 2.8.2.2 Over-threshold alarm mode ====
819 -
820 -Feature: Monitors whether the IDC/VDC exceeds the threshold by setting the detection period and threshold. Alarm if the threshold is exceeded.
821 -
822 -(% style="color:blue" %)**AT Command: AT+ROC=3,a,b,c,d,e**
823 -
824 -(% border="1" cellspacing="3" style="background-color:#f2f2f2; width:510px" %)
825 -|=(% style="width: 163px; background-color: rgb(79, 129, 189); color: white;" %)**Command Example**|=(% style="width: 160px; background-color: rgb(79, 129, 189); color: white;" %)**Parameters**|=(% style="width: 185px; background-color: rgb(79, 129, 189); color: white;" %)**Response/Explanation**
826 -|(% style="width:143px" %)AT+ROC=?|(% style="width:160px" %)Show current ROC setting|(% style="width:185px" %)(((
827 -0,0,0,0(default)
828 -OK
829 -)))
830 -|(% colspan="1" rowspan="5" style="width:143px" %)(((
831 -
832 -
833 -
834 -
835 -AT+ROC=(% style="color:blue" %)**3**(%%),a,b,c,d,e
836 -)))|(% style="width:160px" %)(((
837 -**a: **Set the detection interval
838 -)))|(% style="width:185px" %)(((
839 -Range:  0~~65535s
840 -)))
841 -|(% style="width:160px" %)**b**: Set the IDC alarm trigger condition|(% style="width:185px" %)(((
842 -**0:** Less than the set IDC threshold, Alarm
843 -
844 -**1:** Greater than the set IDC threshold, Alarm
845 -)))
846 -|(% style="width:160px" %)**c**:  Set the VDC alarm trigger condition|(% style="width:185px" %)(((
847 -**0:** Less than the set VDC threshold, Alarm
848 -
849 -**1:** Greater than the set VDC threshold, Alarm
850 -)))
851 -|(% style="width:160px" %)**d**: IDC alarm threshold|(% style="width:185px" %)Unit: uA
852 -|(% style="width:160px" %)**e:** VDC alarm threshold|(% style="width:185px" %)Unit: mV
853 -
854 -**Example:**
855 -
856 -* AT+ROC=3,60,0,0,3000,500  ~/~/The data is checked every 60 seconds. If the IDC is less than 3mA or the VDC is less than 500mV, an alarm is generated.
857 -* AT+ROC=3,180,1,1,3000,500  ~/~/The data is checked every 180 seconds. If the IDC is greater than 3mA or the VDC is greater than 500mV, an alarm is generated.
858 -* AT+ROC=3,300,0,1,3000,500  ~/~/The data is checked every 300 seconds. If the IDC is less than 3mA or the VDC is greater than 500mV, an alarm is generated.
859 -
860 -(% style="color:blue" %)**Downlink Command: 0x09 03 aa bb cc dd ee**
861 -
862 -Format: Function code (0x09) followed by 03 and the remaining 5 bytes.
863 -
864 -(% style="color:blue" %)**aa: **(% style="color:#037691" %)**2 bytes;**(%%) Set the detection interval.(second)
865 -
866 -(% style="color:blue" %)**bb: **(% style="color:#037691" %)**1 byte; **(%%)Set the IDC alarm trigger condition.
867 -
868 -(% style="color:blue" %)**cc: **(% style="color:#037691" %)**1 byte;**(%%) Set the VDC alarm trigger condition.
869 -
870 -(% style="color:blue" %)**dd: **(% style="color:#037691" %)**2 bytes;**(%%) IDC alarm threshold.(uA)
871 -
872 -(% style="color:blue" %)**ee: **(% style="color:#037691" %)**2 bytes; **(%%)VDC alarm threshold.(mV)
873 -
874 -**Example:**
875 -
876 -* Downlink Payload: **09 03 00 3C 00 00 0B B8 01 F4** ~/~/Equal to AT+ROC=3,60,0,0,3000,500
877 -* Downlink Payload: **09 03 00 b4 01 01 0B B8 01 F4**  ~/~/Equal to AT+ROC=3,180,1,1,3000,500
878 -* Downlink Payload: **09 03 01 2C 00 01 0B B8 01 F4** ~/~/Equal to AT+ROC=3,300,0,1,3000,500
879 -
880 -(% style="color:blue" %)**Screenshot of parsing example in TTN:**
881 -
882 -
883 -
884 -
885 885  == 2.9 ​Firmware Change Log ==
886 886  
887 887  
... ... @@ -1048,16 +1048,6 @@
1048 1048  * Example 5: Downlink Payload: 070301F4  **~-~-->**  AT+12VT=500
1049 1049  * Example 6: Downlink Payload: 07030000  **~-~-->**  AT+12VT=0
1050 1050  
1051 -(% style="color:red" %)**Note: Before v1.2, the maximum settable time of 3V3T, 5VT and 12VT is 65535 milliseconds. After v1.2, the maximum settable time of 3V3T, 5VT and 12VT is 180 seconds.**
1052 -
1053 -(% style="color:red" %)**Therefore, the corresponding downlink command is increased by one byte to five bytes.**
1054 -
1055 -**Example: **
1056 -
1057 -* 120s=120000ms(D) =0x01D4C0(H), Downlink Payload: 07 **01** 01 D4 C0  **~-~-->**  AT+3V3T=120000
1058 -* 100s=100000ms(D) =0x0186A0(H), Downlink Payload: 07 **02** 01 86 A0  **~-~-->**  AT+5VT=100000
1059 -* 80s=80000ms(D) =0x013880(H), Downlink Payload: 07 **03** 01 38 80  **~-~-->**  AT+12VT=80000
1060 -
1061 1061  === 3.3.4 Set the Probe Model ===
1062 1062  
1063 1063  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved