... ... @@ -439,9 +439,20 @@
439 439  
440 440  == 5.2 AT commands and LTS5 Panel Data Formats ==
441 441  
442 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**01**A4CBBB0A8E085C02,0,3
442 442  
443 -**Currently, there are two types of panel data formats in LTS5. One is the temperature and humidity type, and the other is the "switch" type. Here is the detailed introduction.**
444 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**02**A4CB00,0,3
444 444  
446 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**03**A4CB00,0,3
447 +
448 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**04**A4CB00,0,3
449 +
450 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**05**A4CB00,0,3
451 +
452 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**06**A4CB00,0,3
453 +
454 +**LTS5 panel data format**:
455 +
445 445  ~1. AT+SEND=1,**01**  **4b69746368656e2d467269676531FFFF  A84041000181D4A8  01  A4CB  BB0A  8E08  5C02**,0,3
446 446  
447 447  **01:** encrypt. 1 Byte. 01 ~-~-> no encryption. This 1-byte information is now invalid; simply write 0x01 instead.
... ... @@ -470,7 +470,6 @@
470 470  
471 471  **5C02:**The humidity of the built-in sensor in LHT65N. 2 Bytes. Humidity: 0x025C/10=60.4%
472 472  
473 -
474 474  2. AT+SEND=1,**01**  **4b69746368656e2d467269676531FFFF**  **A84041000181D4A8**  **02  A4CB  00**,0,3
475 475  
476 476  Specific sections of the data share the same function.
... ... @@ -479,29 +479,12 @@
479 479  
480 480   If Panel Type is 0x03, **Status: 00~-~->Normal; 01~-~->Water Leaking.**
481 481  
482 - If Panel Type is 0x04, **Status: 00~-~->Free; 01~-~->Occupied.**
492 + If Panel Type is 0x04, **Status: 00~-~->Free; 01~-~->Occupied.**
483 483  
484 - If Panel Type is 0x05, **Status: 00~-~->OFF; 01~-~->ON.**
494 + If Panel Type is 0x05, **Status: 00~-~->OFF; 01~-~->ON.**
485 485  
486 - If Panel Type is 0x06, **Status: 00~-~->OFF; 01~-~->Alarm.**
496 + If Panel Type is 0x06, **Status: 00~-~->OFF; 01~-~->Alarm.**
487 487  
488 -
489 -Below are examples of AT commands for each type.
490 -
491 -
492 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**01**A4CBBB0A8E085C02,0,3
493 -
494 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**02**A4CB00,0,3
495 -
496 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**03**A4CB00,0,3
497 -
498 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**04**A4CB00,0,3
499 -
500 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**05**A4CB00,0,3
501 -
502 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**06**A4CB00,0,3
503 -
504 -
505 505  == 5.3 Usage ==
506 506  
507 507  After burning the firmware into LTS5, you can use an LA66 equipped with peer-to-peer firmware to send data to LTS5 via AT commands.