Changes for page LTS5 LoRa HMI Touch Screen
Last modified by BoYang Xie on 2025/07/24 16:47
From version 195.12
edited by BoYang Xie
on 2025/07/24 16:44
on 2025/07/24 16:44
Change comment:
There is no comment for this version
To version 195.3
edited by BoYang Xie
on 2025/07/24 16:19
on 2025/07/24 16:19
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -439,9 +439,20 @@ 439 439 440 440 == 5.2 AT commands and LTS5 Panel Data Formats == 441 441 442 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**01**A4CBBB0A8E085C02,0,3 442 442 443 - **Currently, there are two types of panel data formats in LTS5. Oneis the temperature andhumidity type, and the other is the "switch" type. Here is the detailed introduction.**444 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**02**A4CB00,0,3 444 444 446 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**03**A4CB00,0,3 447 + 448 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**04**A4CB00,0,3 449 + 450 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**05**A4CB00,0,3 451 + 452 +AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**06**A4CB00,0,3 453 + 454 +**LTS5 panel data format**: 455 + 445 445 ~1. AT+SEND=1,**01** **4b69746368656e2d467269676531FFFF A84041000181D4A8 01 A4CB BB0A 8E08 5C02**,0,3 446 446 447 447 **01:** encrypt. 1 Byte. 01 ~-~-> no encryption. This 1-byte information is now invalid; simply write 0x01 instead. ... ... @@ -452,15 +452,15 @@ 452 452 453 453 **01: **Panel Type. 1 Byte. 0x01~-~->Tem & Hum, 454 454 455 - 466 + 0x02~-~->Door, 456 456 457 - 468 + 0x03~-~->Water Leak, 458 458 459 - 470 + 0x04~-~->Occupied, 460 460 461 - 472 + 0x05~-~->Button, 462 462 463 - 474 + 0x06~-~->Alarm, 464 464 465 465 **A4CB: **Battery level//. //2 Bytes. Battery Voltage =0xCBA4&0x3FFF=0x0BA4=2980mV 466 466 ... ... @@ -470,7 +470,6 @@ 470 470 471 471 **5C02:**The humidity of the built-in sensor in LHT65N. 2 Bytes. Humidity: 0x025C/10=60.4% 472 472 473 - 474 474 2. AT+SEND=1,**01** **4b69746368656e2d467269676531FFFF** **A84041000181D4A8** **02 A4CB 00**,0,3 475 475 476 476 Specific sections of the data share the same function. ... ... @@ -477,31 +477,14 @@ 477 477 478 478 **00: Status. **1 Byte//. //If Panel Type is 0x02, **Status: 00~-~->Open; 01~-~->Close.** 479 479 480 - 490 + If Panel Type is 0x03, **Status: 00~-~->Normal; 01~-~->Water Leaking.** 481 481 482 - 492 + If Panel Type is 0x04, **Status: 00~-~->Free; 01~-~->Occupied.** 483 483 484 - 494 + If Panel Type is 0x05, **Status: 00~-~->OFF; 01~-~->ON.** 485 485 486 - 496 + If Panel Type is 0x06, **Status: 00~-~->OFF; 01~-~->Alarm.** 487 487 488 - 489 -Below are examples of AT commands for each type. 490 - 491 - 492 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**01**A4CBBB0A8E085C02,0,3 493 - 494 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**02**A4CB00,0,3 495 - 496 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**03**A4CB00,0,3 497 - 498 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**04**A4CB00,0,3 499 - 500 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**05**A4CB00,0,3 501 - 502 -AT+SEND=1,014b69746368656e2d467269676531FFFFA84041000181D4A8**06**A4CB00,0,3 503 - 504 - 505 505 == 5.3 Usage == 506 506 507 507 After burning the firmware into LTS5, you can use an LA66 equipped with peer-to-peer firmware to send data to LTS5 via AT commands.