From version < 99.1 >
edited by Edwin Chen
on 2022/10/06 17:06
To version < 94.1 >
edited by Bei Jinggeng
on 2022/08/24 15:57
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Bei
Content
... ... @@ -15,7 +15,6 @@
15 15  
16 16  = 1.Introduction =
17 17  
18 -
19 19  == 1.1 What is LT Series I/O Controller ==
20 20  
21 21  (((
... ... @@ -58,7 +58,7 @@
58 58  (((
59 59  
60 60  
61 -(% style="color:#037691" %)**Hardware System:**
60 +**Hardware System:**
62 62  )))
63 63  
64 64  * (((
... ... @@ -83,7 +83,7 @@
83 83  (((
84 84  
85 85  
86 -(% style="color:#037691" %)**Interface for Model: LT22222-L:**
85 +**Interface for Model: LT22222-L:**
87 87  )))
88 88  
89 89  * (((
... ... @@ -108,7 +108,7 @@
108 108  (((
109 109  
110 110  
111 -(% style="color:#037691" %)**LoRa Spec:**
110 +**LoRa Spec:**
112 112  )))
113 113  
114 114  * (((
... ... @@ -184,8 +184,6 @@
184 184  * Firmware upgradable via program port
185 185  * Counting
186 186  
187 -
188 -
189 189  == 1.4  Applications ==
190 190  
191 191  
... ... @@ -196,8 +196,6 @@
196 196  * Smart Cities
197 197  * Smart Factory
198 198  
199 -
200 -
201 201  == 1.5 Hardware Variants ==
202 202  
203 203  
... ... @@ -212,8 +212,6 @@
212 212  * 1 x Counting Port
213 213  )))
214 214  
215 -
216 -
217 217  = 2. Power ON Device =
218 218  
219 219  
... ... @@ -221,8 +221,6 @@
221 221  
222 222  (((
223 223  PWR will on when device is properly powered.
224 -
225 -
226 226  )))
227 227  
228 228  [[image:1653297104069-180.png]]
... ... @@ -231,7 +231,6 @@
231 231  
232 232  = 3. Operation Mode =
233 233  
234 -
235 235  == 3.1 How it works? ==
236 236  
237 237  
... ... @@ -307,8 +307,6 @@
307 307  * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
308 308  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
309 309  
310 -
311 -
312 312  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
313 313  
314 314  
... ... @@ -328,9 +328,8 @@
328 328  * DI is for digital input. DIx=1: high or float, DIx=0: low.
329 329  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
330 330  
319 +(% style="color:red" %)Note: DI3 and DO3 bit are not valid for LT-22222-L
331 331  
332 -(% style="color:red" %)**Note: DI3 and DO3 bit are not valid for LT-22222-L**
333 -
334 334  For example if payload is: [[image:image-20220523175847-2.png]]
335 335  
336 336  
... ... @@ -349,7 +349,6 @@
349 349  * [1] RO1 relay channel is close and the RO1 LED is ON.
350 350  * [0] RO2 relay channel is open and RO2 LED is OFF;
351 351  
352 -
353 353  **LT22222-L:**
354 354  
355 355  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -365,9 +365,6 @@
365 365  ** DO1 is high in case there is load between DO1 and V+.
366 366  ** DO1 LED is off in both case
367 367  
368 -
369 -
370 -
371 371  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
372 372  
373 373  
... ... @@ -391,7 +391,7 @@
391 391  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
392 392  
393 393  (((
394 -(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.**
377 +(% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L.
395 395  )))
396 396  
397 397  (((
... ... @@ -413,8 +413,6 @@
413 413  
414 414  
415 415  (% style="color:#4f81bd" %)**AT Commands for counting:**
416 -
417 -
418 418  )))
419 419  
420 420  (((
... ... @@ -456,7 +456,7 @@
456 456  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
457 457  
458 458  (((
459 -(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
440 +(% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
460 460  )))
461 461  
462 462  
... ... @@ -500,7 +500,7 @@
500 500  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
501 501  
502 502  (((
503 -(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
484 +(% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
504 504  )))
505 505  
506 506  (((
... ... @@ -561,7 +561,7 @@
561 561  )))
562 562  
563 563  (((
564 -(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.**
545 +(% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
565 565  )))
566 566  
567 567  (((
... ... @@ -595,14 +595,11 @@
595 595  * **AT+MOD=1 ** **~-~->**  The normal working mode
596 596  * **AT+ADDMOD6=1**   **~-~->**  Enable trigger
597 597  
598 -
599 599  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
600 600  
601 601  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
602 602  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
603 603  
604 -
605 -
606 606  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
607 607  
608 608  
... ... @@ -610,7 +610,6 @@
610 610  
611 611  Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH>
612 612  
613 -
614 614  **Example:**
615 615  
616 616  AT+AVLIM=3000,6000,0,2000   (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink)
... ... @@ -623,7 +623,6 @@
623 623  
624 624  Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH>
625 625  
626 -
627 627  **Example:**
628 628  
629 629  AT+ACLIM=10000,15000,0,0   (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink)
... ... @@ -642,7 +642,6 @@
642 642  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
643 643  
644 644  
645 -
646 646  (% style="color:#037691" %)**Downlink Command to set Trigger Condition:**
647 647  
648 648  Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM**
... ... @@ -686,13 +686,11 @@
686 686  
687 687  * Each bits shows if the corresponding trigger has been configured.
688 688  
689 -
690 690  **Example:**
691 691  
692 692  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
693 693  
694 694  
695 -
696 696  (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below
697 697  
698 698  [[image:image-20220524090249-3.png]]
... ... @@ -699,13 +699,11 @@
699 699  
700 700  * Each bits shows which status has been trigger on this uplink.
701 701  
702 -
703 703  **Example:**
704 704  
705 705  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
706 706  
707 707  
708 -
709 709  (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below
710 710  
711 711  [[image:image-20220524090456-4.png]]
... ... @@ -712,7 +712,6 @@
712 712  
713 713  * Each bits shows which status has been trigger on this uplink.
714 714  
715 -
716 716  **Example:**
717 717  
718 718  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -720,7 +720,6 @@
720 720  00000101: Means both DI1 and DI2 trigger are enabled.
721 721  
722 722  
723 -
724 724  (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable.
725 725  
726 726  Downlink command to poll MOD6 status:
... ... @@ -731,7 +731,6 @@
731 731  
732 732  
733 733  
734 -
735 735  === 3.3.7 Payload Decoder ===
736 736  
737 737  (((
... ... @@ -755,8 +755,6 @@
755 755  
756 756  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
757 757  
758 -
759 -
760 760  === 3.4.1 Common Commands ===
761 761  
762 762  
... ... @@ -819,7 +819,6 @@
819 819  
820 820  **0x08 FF     **~/~/ Poll an uplink
821 821  
822 -
823 823  **Example**: 0x08FF, ask device to send an Uplink
824 824  
825 825  
... ... @@ -906,8 +906,6 @@
906 906  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
907 907  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
908 908  
909 -
910 -
911 911  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
912 912  
913 913  
... ... @@ -986,7 +986,7 @@
986 986  (((
987 987  
988 988  
989 -(% style="color:red" %)**Note: ATDC setting must be more than 5min**
952 +(% style="color:red" %)Note: ATDC setting must be more than 5min
990 990  )))
991 991  
992 992  
... ... @@ -1014,11 +1014,11 @@
1014 1014  [[image:image-20220524092754-5.png]]
1015 1015  
1016 1016  (((
1017 -(% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.**
980 +(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value.
1018 1018  )))
1019 1019  
1020 1020  (((
1021 -(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
984 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully.
1022 1022  )))
1023 1023  
1024 1024  
... ... @@ -1067,7 +1067,7 @@
1067 1067  
1068 1068   Latching time. Unit: ms
1069 1069  
1070 -(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1033 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully.
1071 1071  
1072 1072  
1073 1073  **Example payload:**
... ... @@ -1116,7 +1116,7 @@
1116 1116  [[image:image-20220524093724-9.png]]
1117 1117  )))
1118 1118  
1119 -(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1082 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully.
1120 1120  
1121 1121  
1122 1122  
... ... @@ -1152,7 +1152,7 @@
1152 1152  
1153 1153  (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms
1154 1154  
1155 -(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.**
1118 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully.
1156 1156  
1157 1157  
1158 1158  **Example payload:**
... ... @@ -1175,6 +1175,7 @@
1175 1175  
1176 1176  
1177 1177  
1141 +
1178 1178  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1179 1179  
1180 1180  
... ... @@ -1247,14 +1247,11 @@
1247 1247  (((
1248 1248  range: aa bb cc:0 to 16777215,  (unit:second)
1249 1249  
1250 -
1251 -
1252 1252  
1253 1253  )))
1254 1254  
1255 1255  ==== 3.4.2.20 Reset save DR DO state ====
1256 1256  
1257 -
1258 1258  * (% style="color:#037691" %)**AT Command:**
1259 1259  
1260 1260  **AT+RODORET=1  **~/~/ RODO will close when the device joining the network. (default)
... ... @@ -1269,11 +1269,8 @@
1269 1269  (((
1270 1270  
1271 1271  
1272 -
1273 -
1274 1274  ==== 3.4.2.21 Encrypted payload ====
1275 1275  
1276 -
1277 1277  * (% style="color:#037691" %)**AT Command:**
1278 1278  
1279 1279  **AT+DECRYPT=1  **~/~/ The payload is uploaded without encryption
... ... @@ -1281,11 +1281,8 @@
1281 1281  **AT+DECRYPT=0  **~/~/Encrypt when uploading payload (default)
1282 1282  
1283 1283  
1284 -
1285 -
1286 1286  ==== 3.4.2.22 Get sensor value ====
1287 1287  
1288 -
1289 1289  * (% style="color:#037691" %)**AT Command:**
1290 1290  
1291 1291  **AT+GETSENSORVALUE=0  **~/~/ The serial port gets the reading of the current sensor
... ... @@ -1293,11 +1293,8 @@
1293 1293  **AT+GETSENSORVALUE=1  **~/~/The serial port gets the current sensor reading and uploads it.
1294 1294  
1295 1295  
1296 -
1297 -
1298 1298  ==== 3.4.2.23 Resets the downlink packet count ====
1299 1299  
1300 -
1301 1301  * (% style="color:#037691" %)**AT Command:**
1302 1302  
1303 1303  **AT+DISFCNTCHECK=0  **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default)
... ... @@ -1305,11 +1305,8 @@
1305 1305  **AT+DISFCNTCHECK=1  **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count.
1306 1306  
1307 1307  
1308 -
1309 -
1310 1310  ==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ====
1311 1311  
1312 -
1313 1313  * (% style="color:#037691" %)**AT Command:**
1314 1314  
1315 1315   **AT+DISMACANS=0**  ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default)
... ... @@ -1321,12 +1321,8 @@
1321 1321  
1322 1322  **0x21 00 01 ** ~/~/ Set  the DISMACANS=1
1323 1323  
1324 -
1325 -
1326 -
1327 1327  ==== 3.4.2.25 Copy downlink to uplink ====
1328 1328  
1329 -
1330 1330  * (% style="color:#037691" %)**AT Command**(%%)**:**
1331 1331  
1332 1332   **AT+RPL=5**  ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100.
... ... @@ -1345,16 +1345,11 @@
1345 1345  
1346 1346  ==== 3.4.2.26 Query version number and frequency band 、TDC ====
1347 1347  
1348 -
1349 1349  * (((
1350 -(% style="color:#037691" %)**Downlink Payload**(%%)**:**
1351 -
1352 -**26 01  ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time.
1353 -
1354 -
1294 +(% style="color:#037691" %)**Downlink Payload**(%%)**: 26 01  ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time.
1355 1355  )))
1356 1356  
1357 -**Example:**
1297 +Example:
1358 1358  
1359 1359  [[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]]
1360 1360  
... ... @@ -1460,10 +1460,10 @@
1460 1460  )))
1461 1461  
1462 1462  * (((
1463 -Connect sensor's output to DI1-
1403 +Connect sensors output to DI1-
1464 1464  )))
1465 1465  * (((
1466 -Connect sensor's VCC to DI1+.
1406 +Connect sensors VCC to DI1+.
1467 1467  )))
1468 1468  
1469 1469  (((
... ... @@ -1471,11 +1471,11 @@
1471 1471  )))
1472 1472  
1473 1473  (((
1474 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1**+** / 1K.**
1414 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ / 1K.**
1475 1475  )))
1476 1476  
1477 1477  (((
1478 -If** DI1+ **= **12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.
1418 +If DI1+ = 12v, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.
1479 1479  )))
1480 1480  
1481 1481  (((
... ... @@ -1493,10 +1493,10 @@
1493 1493  )))
1494 1494  
1495 1495  * (((
1496 -Connect sensor's output to DI1+
1436 +Connect sensors output to DI1+
1497 1497  )))
1498 1498  * (((
1499 -Connect sensor's GND DI1-.
1439 +Connect sensors GND DI1-.
1500 1500  )))
1501 1501  
1502 1502  (((
... ... @@ -1526,10 +1526,10 @@
1526 1526  )))
1527 1527  
1528 1528  * (((
1529 -Connect sensor's output to DI1+ with a serial 50K resistor
1469 +Connect sensors output to DI1+ with a serial 50K resistor
1530 1530  )))
1531 1531  * (((
1532 -Connect sensor's GND DI1-.
1472 +Connect sensors GND DI1-.
1533 1533  )))
1534 1534  
1535 1535  (((
... ... @@ -1596,7 +1596,6 @@
1596 1596  
1597 1597  [[image:image-20220524100215-9.png]]
1598 1598  
1599 -
1600 1600  [[image:image-20220524100215-10.png||height="382" width="723"]]
1601 1601  
1602 1602  
... ... @@ -1970,7 +1970,7 @@
1970 1970  
1971 1971  (((
1972 1972  (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]].
1973 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]].
1912 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].
1974 1974  (% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update.
1975 1975  
1976 1976  
... ... @@ -2026,7 +2026,6 @@
2026 2026  (((
2027 2027  Assume we have a LG02 working in the frequency 868400000 now , below is the step.
2028 2028  
2029 -
2030 2030  
2031 2031  )))
2032 2032  )))
... ... @@ -2033,14 +2033,10 @@
2033 2033  
2034 2034  (((
2035 2035  (% style="color:blue" %)**Step1**(%%):  Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.
2036 -
2037 -
2038 2038  )))
2039 2039  
2040 2040  (((
2041 2041  [[image:1653360231087-571.png||height="401" width="727"]]
2042 -
2043 -
2044 2044  )))
2045 2045  
2046 2046  (((
... ... @@ -2048,11 +2048,8 @@
2048 2048  )))
2049 2049  
2050 2050  
2051 -
2052 2052  (((
2053 2053  (% style="color:blue" %)**Step2**(%%)**:  **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:
2054 -
2055 -
2056 2056  )))
2057 2057  
2058 2058  (((
... ... @@ -2107,18 +2107,8 @@
2107 2107  After restart, the status before power failure will be read from flash.
2108 2108  
2109 2109  
2110 -== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2111 2111  
2112 -LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below:
2113 -
2114 -[[image:image-20221006170630-1.png||height="610" width="945"]]
2115 -
2116 -
2117 -
2118 -
2119 2119  = 6. Trouble Shooting =
2120 -
2121 -
2122 2122  )))
2123 2123  
2124 2124  (((
... ... @@ -2178,8 +2178,6 @@
2178 2178  * (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
2179 2179  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2180 2180  
2181 -
2182 -
2183 2183  = 8. Packing Info =
2184 2184  
2185 2185  
... ... @@ -2197,8 +2197,6 @@
2197 2197  * Package Size / pcs : 14.5 x 8 x 5 cm
2198 2198  * Weight / pcs : 170g
2199 2199  
2200 -
2201 -
2202 2202  = 9. Support =
2203 2203  
2204 2204  
... ... @@ -2220,3 +2220,4 @@
2220 2220  * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2221 2221  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2222 2222  
2140 +
image-20221006170630-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Edwin
Size
... ... @@ -1,1 +1,0 @@
1 -486.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0