<
From version < 97.2 >
edited by Xiaoling
on 2022/09/12 09:21
To version < 101.1 >
edited by Bei Jinggeng
on 2022/10/08 09:59
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -185,8 +185,6 @@
185 185  * Counting
186 186  
187 187  
188 -
189 -
190 190  == 1.4  Applications ==
191 191  
192 192  
... ... @@ -198,8 +198,6 @@
198 198  * Smart Factory
199 199  
200 200  
201 -
202 -
203 203  == 1.5 Hardware Variants ==
204 204  
205 205  
... ... @@ -215,8 +215,6 @@
215 215  )))
216 216  
217 217  
218 -
219 -
220 220  = 2. Power ON Device =
221 221  
222 222  
... ... @@ -311,8 +311,6 @@
311 311  * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
312 312  
313 313  
314 -
315 -
316 316  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
317 317  
318 318  
... ... @@ -332,8 +332,6 @@
332 332  * DI is for digital input. DIx=1: high or float, DIx=0: low.
333 333  * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float.
334 334  
335 -
336 -
337 337  (% style="color:red" %)**Note: DI3 and DO3 bit are not valid for LT-22222-L**
338 338  
339 339  For example if payload is: [[image:image-20220523175847-2.png]]
... ... @@ -354,8 +354,6 @@
354 354  * [1] RO1 relay channel is close and the RO1 LED is ON.
355 355  * [0] RO2 relay channel is open and RO2 LED is OFF;
356 356  
357 -
358 -
359 359  **LT22222-L:**
360 360  
361 361  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -373,8 +373,6 @@
373 373  
374 374  
375 375  
376 -
377 -
378 378  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
379 379  
380 380  
... ... @@ -602,8 +602,6 @@
602 602  * **AT+MOD=1 ** **~-~->**  The normal working mode
603 603  * **AT+ADDMOD6=1**   **~-~->**  Enable trigger
604 604  
605 -
606 -
607 607  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
608 608  
609 609  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
... ... @@ -610,8 +610,6 @@
610 610  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
611 611  
612 612  
613 -
614 -
615 615  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
616 616  
617 617  
... ... @@ -695,8 +695,6 @@
695 695  
696 696  * Each bits shows if the corresponding trigger has been configured.
697 697  
698 -
699 -
700 700  **Example:**
701 701  
702 702  10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW
... ... @@ -709,8 +709,6 @@
709 709  
710 710  * Each bits shows which status has been trigger on this uplink.
711 711  
712 -
713 -
714 714  **Example:**
715 715  
716 716  10000000: Means this packet is trigger by AC1_LOW. Means voltage too low.
... ... @@ -723,8 +723,6 @@
723 723  
724 724  * Each bits shows which status has been trigger on this uplink.
725 725  
726 -
727 -
728 728  **Example:**
729 729  
730 730  00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1.
... ... @@ -768,8 +768,6 @@
768 768  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
769 769  
770 770  
771 -
772 -
773 773  === 3.4.1 Common Commands ===
774 774  
775 775  
... ... @@ -920,8 +920,6 @@
920 920  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
921 921  
922 922  
923 -
924 -
925 925  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
926 926  
927 927  
... ... @@ -1161,7 +1161,7 @@
1161 1161  
1162 1162  (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status:
1163 1163  
1164 -[[image:image-20220714135731-1.png||height="406" width="627"]]
1136 +[[image:image-20221008095908-1.png||height="364" width="564"]]
1165 1165  
1166 1166  
1167 1167  (% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms
... ... @@ -1485,11 +1485,11 @@
1485 1485  )))
1486 1486  
1487 1487  (((
1488 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1**+** / 1K.**
1460 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1**+** / 1K.**
1489 1489  )))
1490 1490  
1491 1491  (((
1492 -If** DI1+ **= **12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.
1464 +If** DI1+ **= **12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal.
1493 1493  )))
1494 1494  
1495 1495  (((
... ... @@ -2121,7 +2121,15 @@
2121 2121  After restart, the status before power failure will be read from flash.
2122 2122  
2123 2123  
2096 +== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? ==
2124 2124  
2098 +LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below:
2099 +
2100 +[[image:image-20221006170630-1.png||height="610" width="945"]]
2101 +
2102 +
2103 +
2104 +
2125 2125  = 6. Trouble Shooting =
2126 2126  
2127 2127  
... ... @@ -2185,8 +2185,6 @@
2185 2185  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2186 2186  
2187 2187  
2188 -
2189 -
2190 2190  = 8. Packing Info =
2191 2191  
2192 2192  
... ... @@ -2205,8 +2205,6 @@
2205 2205  * Weight / pcs : 170g
2206 2206  
2207 2207  
2208 -
2209 -
2210 2210  = 9. Support =
2211 2211  
2212 2212  
... ... @@ -2227,5 +2227,3 @@
2227 2227  * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]]
2228 2228  * [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]]
2229 2229  * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
2230 -
2231 -
image-20221006170630-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Edwin
Size
... ... @@ -1,0 +1,1 @@
1 +486.5 KB
Content
image-20221008095908-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Bei
Size
... ... @@ -1,0 +1,1 @@
1 +41.8 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0