From version < 90.5 >
edited by Xiaoling
on 2022/08/18 11:57
To version < 91.1 >
edited by Bei Jinggeng
on 2022/08/24 10:10
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Bei
Content
... ... @@ -36,7 +36,7 @@
36 36  )))
37 37  
38 38  (((
39 -1) If users area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.
39 +1) If user's area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.
40 40  )))
41 41  
42 42  (((
... ... @@ -185,6 +185,7 @@
185 185  
186 186  
187 187  
188 +
188 188  == 1.4  Applications ==
189 189  
190 190  
... ... @@ -197,6 +197,7 @@
197 197  
198 198  
199 199  
201 +
200 200  == 1.5 Hardware Variants ==
201 201  
202 202  
... ... @@ -212,6 +212,7 @@
212 212  )))
213 213  
214 214  
217 +
215 215  = 2. Power ON Device =
216 216  
217 217  
... ... @@ -304,6 +304,7 @@
304 304  
305 305  
306 306  
310 +
307 307  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
308 308  
309 309  
... ... @@ -360,6 +360,7 @@
360 360  
361 361  
362 362  
367 +
363 363  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
364 364  
365 365  
... ... @@ -884,6 +884,7 @@
884 884  
885 885  
886 886  
892 +
887 887  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
888 888  
889 889  
... ... @@ -1227,8 +1227,94 @@
1227 1227  
1228 1228  )))
1229 1229  
1236 +==== 3.4.2.20 Reset save DR DO state ====
1230 1230  
1238 +* (% style="color:#037691" %)**AT Command:**
1231 1231  
1240 +**AT+RODORET=1  **~/~/ RODO will close when the device joining the network. (default)
1241 +
1242 +**AT+RODORET=0  **~/~/After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network.
1243 +
1244 +
1245 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):**
1246 +
1247 +**0x AD aa  **~/~/ same as AT+RODORET =aa
1248 +
1249 +(((
1250 +
1251 +
1252 +==== 3.4.2.21 Encrypted payload ====
1253 +
1254 +* (% style="color:#037691" %)**AT Command:**
1255 +
1256 +**AT+DECRYPT=1  **~/~/ The payload is uploaded without encryption
1257 +
1258 +**AT+DECRYPT=0  **~/~/Encrypt when uploading payload (default)
1259 +
1260 +
1261 +==== 3.4.2.22 Get sensor value ====
1262 +
1263 +* (% style="color:#037691" %)**AT Command:**
1264 +
1265 +**AT+GETSENSORVALUE=0  **~/~/ The serial port gets the reading of the current sensor
1266 +
1267 +**AT+GETSENSORVALUE=1  **~/~/The serial port gets the current sensor reading and uploads it.
1268 +
1269 +
1270 +==== 3.4.2.23 Resets the downlink packet count ====
1271 +
1272 +* (% style="color:#037691" %)**AT Command:**
1273 +
1274 +**AT+DISFCNTCHECK=0  **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default)
1275 +
1276 +**AT+DISFCNTCHECK=1  **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count.
1277 +
1278 +
1279 +==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ====
1280 +
1281 +* (% style="color:#037691" %)**AT Command:**
1282 +
1283 + **AT+DISMACANS=0**  ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default)
1284 +
1285 + **AT+DISMACANS=1**      ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part.
1286 +
1287 +
1288 +* (% style="color:#037691" %)**Downlink Payload **(%%)**:**
1289 +
1290 +**0x21 00 01 ** ~/~/ Set  the DISMACANS=1
1291 +
1292 +==== 3.4.2.25 Copy downlink to uplink ====
1293 +
1294 +* (% style="color:#037691" %)**AT Command**(%%)**:**
1295 +
1296 + **AT+RPL=5**  ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100.
1297 +
1298 +Example:**aa xx xx xx xx**         ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent.
1299 +
1300 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]]
1301 +
1302 +For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77.
1303 +
1304 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]]
1305 +
1306 +For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned.
1307 +
1308 +
1309 +
1310 +==== 3.4.2.26 Query version number and frequency band 、TDC ====
1311 +
1312 +* (((
1313 +(% style="color:#037691" %)**Downlink Payload**(%%)**: 26 01  ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time.
1314 +)))
1315 +
1316 +Example:
1317 +
1318 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]]
1319 +
1320 +
1321 +
1322 +)))
1323 +
1232 1232  == 3.5 Integrate with Mydevice ==
1233 1233  
1234 1234  
... ... @@ -1795,6 +1795,8 @@
1795 1795  2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting.
1796 1796  3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means.
1797 1797  4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5
1890 +
1891 +
1798 1798  )))
1799 1799  
1800 1800  (((
... ... @@ -2025,8 +2025,6 @@
2025 2025  * (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
2026 2026  
2027 2027  
2028 -
2029 -
2030 2030  = 8. Packing Info =
2031 2031  
2032 2032  
... ... @@ -2045,8 +2045,6 @@
2045 2045  * Weight / pcs : 170g
2046 2046  
2047 2047  
2048 -
2049 -
2050 2050  = 9. Support =
2051 2051  
2052 2052  
... ... @@ -2058,7 +2058,6 @@
2058 2058  
2059 2059  
2060 2060  
2061 -
2062 2062  
2063 2063  )))
2064 2064  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved