Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -15,6 +15,7 @@ 15 15 16 16 = 1.Introduction = 17 17 18 + 18 18 == 1.1 What is LT Series I/O Controller == 19 19 20 20 ((( ... ... @@ -36,7 +36,7 @@ 36 36 ))) 37 37 38 38 ((( 39 -1) If user ’s area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.40 +1) If user's area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless. 40 40 ))) 41 41 42 42 ((( ... ... @@ -57,7 +57,7 @@ 57 57 ((( 58 58 59 59 60 -**Hardware System:** 61 +(% style="color:#037691" %)**Hardware System:** 61 61 ))) 62 62 63 63 * ((( ... ... @@ -82,7 +82,7 @@ 82 82 ((( 83 83 84 84 85 -**Interface for Model: LT22222-L:** 86 +(% style="color:#037691" %)**Interface for Model: LT22222-L:** 86 86 ))) 87 87 88 88 * ((( ... ... @@ -107,7 +107,7 @@ 107 107 ((( 108 108 109 109 110 -**LoRa Spec:** 111 +(% style="color:#037691" %)**LoRa Spec:** 111 111 ))) 112 112 113 113 * ((( ... ... @@ -177,7 +177,7 @@ 177 177 178 178 * LoRaWAN Class A & Class C protocol 179 179 * Optional Customized LoRa Protocol 180 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 181 +* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 181 181 * AT Commands to change parameters 182 182 * Remote configure parameters via LoRa Downlink 183 183 * Firmware upgradable via program port ... ... @@ -184,9 +184,6 @@ 184 184 * Counting 185 185 186 186 187 - 188 - 189 - 190 190 == 1.4 Applications == 191 191 192 192 ... ... @@ -198,9 +198,6 @@ 198 198 * Smart Factory 199 199 200 200 201 - 202 - 203 - 204 204 == 1.5 Hardware Variants == 205 205 206 206 ... ... @@ -216,8 +216,6 @@ 216 216 ))) 217 217 218 218 219 - 220 - 221 221 = 2. Power ON Device = 222 222 223 223 ... ... @@ -225,6 +225,8 @@ 225 225 226 226 ((( 227 227 PWR will on when device is properly powered. 221 + 222 + 228 228 ))) 229 229 230 230 [[image:1653297104069-180.png]] ... ... @@ -233,6 +233,7 @@ 233 233 234 234 = 3. Operation Mode = 235 235 231 + 236 236 == 3.1 How it works? == 237 237 238 238 ... ... @@ -287,6 +287,7 @@ 287 287 [[image:1653298023685-319.png]] 288 288 289 289 286 + 290 290 ((( 291 291 (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 292 292 ))) ... ... @@ -297,6 +297,7 @@ 297 297 298 298 == 3.3 Uplink Payload == 299 299 297 + 300 300 There are five working modes + one interrupt mode on LT for different type application: 301 301 302 302 * (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO ... ... @@ -306,8 +306,10 @@ 306 306 * (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 307 307 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 308 308 307 + 309 309 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 310 310 310 + 311 311 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 312 312 313 313 [[image:image-20220523174024-3.png]] ... ... @@ -324,7 +324,7 @@ 324 324 * DI is for digital input. DIx=1: high or float, DIx=0: low. 325 325 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 326 326 327 -(% style="color:red" %)Note: DI3 and DO3 bit are not valid for LT-22222-L 327 +(% style="color:red" %)**Note: DI3 and DO3 bit are not valid for LT-22222-L** 328 328 329 329 For example if payload is: [[image:image-20220523175847-2.png]] 330 330 ... ... @@ -359,6 +359,8 @@ 359 359 ** DO1 is high in case there is load between DO1 and V+. 360 360 ** DO1 LED is off in both case 361 361 362 + 363 + 362 362 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 363 363 364 364 ... ... @@ -382,7 +382,7 @@ 382 382 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 383 383 384 384 ((( 385 -(% style="color:red" %)Note: DO3 bit is not valid for LT-22222-L. 387 +(% style="color:red" %)**Note: DO3 bit is not valid for LT-22222-L.** 386 386 ))) 387 387 388 388 ((( ... ... @@ -404,6 +404,8 @@ 404 404 405 405 406 406 (% style="color:#4f81bd" %)**AT Commands for counting:** 409 + 410 + 407 407 ))) 408 408 409 409 ((( ... ... @@ -427,6 +427,7 @@ 427 427 428 428 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 429 429 434 + 430 430 **LT22222-L**: This mode the DI1 is used as a counting pin. 431 431 432 432 [[image:image-20220523181246-5.png]] ... ... @@ -444,7 +444,7 @@ 444 444 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 445 445 446 446 ((( 447 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 452 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 448 448 ))) 449 449 450 450 ... ... @@ -488,7 +488,7 @@ 488 488 * DO is for reverse digital output. DOx=1: output low, DOx=0: high or float. 489 489 490 490 ((( 491 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 496 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 492 492 ))) 493 493 494 494 ((( ... ... @@ -549,7 +549,7 @@ 549 549 ))) 550 550 551 551 ((( 552 -(% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 557 +(% style="color:red" %)**Note: DO3 is not valid for LT-22222-L.** 553 553 ))) 554 554 555 555 ((( ... ... @@ -588,6 +588,7 @@ 588 588 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 589 589 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 590 590 596 + 591 591 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 592 592 593 593 ... ... @@ -595,6 +595,7 @@ 595 595 596 596 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> 597 597 604 + 598 598 **Example:** 599 599 600 600 AT+AVLIM=3000,6000,0,2000 (If AVI1 voltage lower than 3v or higher than 6v. or AV2 voltage is higher than 2v, LT will trigger Uplink) ... ... @@ -607,6 +607,7 @@ 607 607 608 608 Format: AT+ACLIM=<AC1_LIMIT_LOW>,< AC1_LIMIT_HIGH>,<AC2_LIMIT_LOW>,< AC2_LIMIT_HIGH> 609 609 617 + 610 610 **Example:** 611 611 612 612 AT+ACLIM=10000,15000,0,0 (If ACI1 voltage lower than 10mA or higher than 15mA, trigger an uplink) ... ... @@ -625,6 +625,7 @@ 625 625 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 626 626 627 627 636 + 628 628 (% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 629 629 630 630 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** ... ... @@ -673,6 +673,7 @@ 673 673 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW 674 674 675 675 685 + 676 676 (% style="color:#4f81bd" %)**TRI Status1**(%%) is a combination to show which condition is trigger. Totally 1byte as below 677 677 678 678 [[image:image-20220524090249-3.png]] ... ... @@ -684,6 +684,7 @@ 684 684 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. 685 685 686 686 697 + 687 687 (% style="color:#4f81bd" %)**TRI_DI FLAG+STA **(%%)is a combination to show which condition is trigger. Totally 1byte as below 688 688 689 689 [[image:image-20220524090456-4.png]] ... ... @@ -697,6 +697,7 @@ 697 697 00000101: Means both DI1 and DI2 trigger are enabled. 698 698 699 699 711 + 700 700 (% style="color:#4f81bd" %)**Enable/Disable MOD6 **(%%): 0x01: MOD6 is enable. 0x00: MOD6 is disable. 701 701 702 702 Downlink command to poll MOD6 status: ... ... @@ -707,19 +707,20 @@ 707 707 708 708 709 709 722 + 710 710 === 3.3.7 Payload Decoder === 711 711 712 712 ((( 713 713 714 714 715 -**Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 716 - 717 - 728 +**Decoder for TTN/loraserver/ChirpStack**: [[https:~~/~~/www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0>>https://www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0]] 718 718 ))) 719 719 720 720 732 + 721 721 == 3.4 Configure LT via AT or Downlink == 722 722 735 + 723 723 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 724 724 725 725 ((( ... ... @@ -730,8 +730,10 @@ 730 730 731 731 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 732 732 746 + 733 733 === 3.4.1 Common Commands === 734 734 749 + 735 735 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 736 736 737 737 ... ... @@ -741,6 +741,7 @@ 741 741 742 742 ==== 3.4.2.1 Set Transmit Interval ==== 743 743 759 + 744 744 Set device uplink interval. 745 745 746 746 * (% style="color:#037691" %)**AT Command:** ... ... @@ -760,6 +760,7 @@ 760 760 761 761 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 762 762 779 + 763 763 Set work mode. 764 764 765 765 * (% style="color:#037691" %)**AT Command:** ... ... @@ -779,6 +779,7 @@ 779 779 780 780 ==== 3.4.2.3 Poll an uplink ==== 781 781 799 + 782 782 * (% style="color:#037691" %)**AT Command:** 783 783 784 784 There is no AT Command to poll uplink ... ... @@ -788,6 +788,7 @@ 788 788 789 789 **0x08 FF **~/~/ Poll an uplink 790 790 809 + 791 791 **Example**: 0x08FF, ask device to send an Uplink 792 792 793 793 ... ... @@ -795,6 +795,7 @@ 795 795 796 796 ==== 3.4.2.4 Enable Trigger Mode ==== 797 797 817 + 798 798 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 799 799 800 800 * (% style="color:#037691" %)**AT Command:** ... ... @@ -815,6 +815,7 @@ 815 815 816 816 ==== 3.4.2.5 Poll trigger settings ==== 817 817 838 + 818 818 Poll trigger settings, 819 819 820 820 * (% style="color:#037691" %)**AT Command:** ... ... @@ -831,6 +831,7 @@ 831 831 832 832 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 833 833 855 + 834 834 Enable Disable DI1/DI2/DI2 as trigger, 835 835 836 836 * (% style="color:#037691" %)**AT Command:** ... ... @@ -851,6 +851,7 @@ 851 851 852 852 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 853 853 876 + 854 854 Set DI1 or DI3(for LT-33222-L) trigger. 855 855 856 856 * (% style="color:#037691" %)**AT Command:** ... ... @@ -870,8 +870,10 @@ 870 870 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 871 871 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 872 872 896 + 873 873 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 874 874 899 + 875 875 Set DI2 trigger. 876 876 877 877 * (% style="color:#037691" %)**AT Command:** ... ... @@ -898,6 +898,7 @@ 898 898 899 899 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 900 900 926 + 901 901 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 902 902 903 903 * (% style="color:#037691" %)**AT Command** ... ... @@ -914,6 +914,7 @@ 914 914 915 915 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 916 916 943 + 917 917 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 918 918 919 919 * (% style="color:#037691" %)**AT Command** ... ... @@ -930,6 +930,7 @@ 930 930 931 931 ==== 3.4.2.11 Trigger – Set minimum interval ==== 932 932 960 + 933 933 Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 934 934 935 935 * (% style="color:#037691" %)**AT Command** ... ... @@ -944,7 +944,7 @@ 944 944 ((( 945 945 946 946 947 -(% style="color:red" %)Note: ATDC setting must be more than 5min 975 +(% style="color:red" %)**Note: ATDC setting must be more than 5min** 948 948 ))) 949 949 950 950 ... ... @@ -952,6 +952,7 @@ 952 952 953 953 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 954 954 983 + 955 955 * (% style="color:#037691" %)**AT Command** 956 956 957 957 There is no AT Command to control Digital Output ... ... @@ -971,11 +971,11 @@ 971 971 [[image:image-20220524092754-5.png]] 972 972 973 973 ((( 974 -(% style="color:red" %)Note: For LT-22222-L, there is no DO3, the last byte can use any value. 1003 +(% style="color:red" %)**Note: For LT-22222-L, there is no DO3, the last byte can use any value.** 975 975 ))) 976 976 977 977 ((( 978 -(% style="color:red" %)Device will upload a packet if downlink code executes successfully. 1007 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 979 979 ))) 980 980 981 981 ... ... @@ -983,6 +983,7 @@ 983 983 984 984 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 985 985 1015 + 986 986 * (% style="color:#037691" %)**AT Command** 987 987 988 988 There is no AT Command to control Digital Output ... ... @@ -1019,11 +1019,11 @@ 1019 1019 [[image:image-20220524093351-8.png]] 1020 1020 1021 1021 1022 -(% style="color:#4f81bd" %)**Sixth and Seventh Byte**: 1052 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**: 1023 1023 1024 1024 Latching time. Unit: ms 1025 1025 1026 -Device will upload a packet if downlink code executes successfully. 1056 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1027 1027 1028 1028 1029 1029 **Example payload:** ... ... @@ -1049,6 +1049,7 @@ 1049 1049 1050 1050 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1051 1051 1082 + 1052 1052 * (% style="color:#037691" %)**AT Command:** 1053 1053 1054 1054 There is no AT Command to control Relay Output ... ... @@ -1071,7 +1071,7 @@ 1071 1071 [[image:image-20220524093724-9.png]] 1072 1072 ))) 1073 1073 1074 -Device will upload a packet if downlink code executes successfully. 1105 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1075 1075 1076 1076 1077 1077 ... ... @@ -1078,6 +1078,7 @@ 1078 1078 1079 1079 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1080 1080 1112 + 1081 1081 * (% style="color:#037691" %)**AT Command:** 1082 1082 1083 1083 There is no AT Command to control Relay Output ... ... @@ -1101,12 +1101,12 @@ 1101 1101 1102 1102 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1103 1103 1104 -[[image:image-2022 0714135731-1.png||height="406" width="627"]]1136 +[[image:image-20221008095908-1.png||height="364" width="564"]] 1105 1105 1106 1106 1107 -(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms 1139 +(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1108 1108 1109 -Device will upload a packet if downlink code executes successfully. 1141 +(% style="color:red" %)**Device will upload a packet if downlink code executes successfully.** 1110 1110 1111 1111 1112 1112 **Example payload:** ... ... @@ -1129,9 +1129,9 @@ 1129 1129 1130 1130 1131 1131 1132 - 1133 1133 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1134 1134 1166 + 1135 1135 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1136 1136 1137 1137 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1148,6 +1148,7 @@ 1148 1148 1149 1149 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1150 1150 1183 + 1151 1151 * (% style="color:#037691" %)**AT Command:** 1152 1152 1153 1153 **AT+SETCNT=aa,(bb cc dd ee) ** ... ... @@ -1170,6 +1170,7 @@ 1170 1170 1171 1171 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1172 1172 1206 + 1173 1173 Clear counting for counting mode 1174 1174 1175 1175 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1186,6 +1186,7 @@ 1186 1186 1187 1187 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1188 1188 1223 + 1189 1189 * (% style="color:#037691" %)**AT Command:** 1190 1190 1191 1191 **AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) ... ... @@ -1198,13 +1198,124 @@ 1198 1198 ((( 1199 1199 range: aa bb cc:0 to 16777215, (unit:second) 1200 1200 1236 + 1237 + 1201 1201 1202 1202 ))) 1203 1203 1241 +==== 3.4.2.20 Reset save DR DO state ==== 1204 1204 1205 1205 1244 +* (% style="color:#037691" %)**AT Command:** 1245 + 1246 +**AT+RODORET=1 **~/~/ RODO will close when the device joining the network. (default) 1247 + 1248 +**AT+RODORET=0 **~/~/After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1249 + 1250 + 1251 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1252 + 1253 +**0x AD aa **~/~/ same as AT+RODORET =aa 1254 + 1255 +((( 1256 + 1257 + 1258 + 1259 + 1260 +==== 3.4.2.21 Encrypted payload ==== 1261 + 1262 + 1263 +* (% style="color:#037691" %)**AT Command:** 1264 + 1265 +**AT+DECRYPT=1 **~/~/ The payload is uploaded without encryption 1266 + 1267 +**AT+DECRYPT=0 **~/~/Encrypt when uploading payload (default) 1268 + 1269 + 1270 + 1271 + 1272 +==== 3.4.2.22 Get sensor value ==== 1273 + 1274 + 1275 +* (% style="color:#037691" %)**AT Command:** 1276 + 1277 +**AT+GETSENSORVALUE=0 **~/~/ The serial port gets the reading of the current sensor 1278 + 1279 +**AT+GETSENSORVALUE=1 **~/~/The serial port gets the current sensor reading and uploads it. 1280 + 1281 + 1282 + 1283 + 1284 +==== 3.4.2.23 Resets the downlink packet count ==== 1285 + 1286 + 1287 +* (% style="color:#037691" %)**AT Command:** 1288 + 1289 +**AT+DISFCNTCHECK=0 **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1290 + 1291 +**AT+DISFCNTCHECK=1 **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1292 + 1293 + 1294 + 1295 + 1296 +==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1297 + 1298 + 1299 +* (% style="color:#037691" %)**AT Command:** 1300 + 1301 + **AT+DISMACANS=0** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1302 + 1303 + **AT+DISMACANS=1** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1304 + 1305 + 1306 +* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1307 + 1308 +**0x21 00 01 ** ~/~/ Set the DISMACANS=1 1309 + 1310 + 1311 + 1312 + 1313 +==== 3.4.2.25 Copy downlink to uplink ==== 1314 + 1315 + 1316 +* (% style="color:#037691" %)**AT Command**(%%)**:** 1317 + 1318 + **AT+RPL=5** ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100. 1319 + 1320 +Example:**aa xx xx xx xx** ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent. 1321 + 1322 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]] 1323 + 1324 +For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77. 1325 + 1326 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]] 1327 + 1328 +For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned. 1329 + 1330 + 1331 + 1332 +==== 3.4.2.26 Query version number and frequency band 、TDC ==== 1333 + 1334 + 1335 +* ((( 1336 +(% style="color:#037691" %)**Downlink Payload**(%%)**:** 1337 + 1338 +**26 01 ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time. 1339 + 1340 + 1341 +))) 1342 + 1343 +**Example:** 1344 + 1345 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1346 + 1347 + 1348 + 1349 +))) 1350 + 1206 1206 == 3.5 Integrate with Mydevice == 1207 1207 1353 + 1208 1208 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: 1209 1209 1210 1210 ((( ... ... @@ -1213,6 +1213,8 @@ 1213 1213 1214 1214 ((( 1215 1215 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1362 + 1363 + 1216 1216 ))) 1217 1217 1218 1218 [[image:image-20220719105525-1.png||height="377" width="677"]] ... ... @@ -1252,8 +1252,10 @@ 1252 1252 1253 1253 == 3.6 Interface Detail == 1254 1254 1403 + 1255 1255 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1256 1256 1406 + 1257 1257 Support NPN Type sensor 1258 1258 1259 1259 [[image:1653356991268-289.png]] ... ... @@ -1262,6 +1262,7 @@ 1262 1262 1263 1263 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1264 1264 1415 + 1265 1265 ((( 1266 1266 The DI port of LT-22222-L can support NPN or PNP output sensor. 1267 1267 ))) ... ... @@ -1268,7 +1268,9 @@ 1268 1268 1269 1269 ((( 1270 1270 ((( 1271 -Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high 1422 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high. 1423 + 1424 + 1272 1272 ))) 1273 1273 ))) 1274 1274 ... ... @@ -1293,10 +1293,10 @@ 1293 1293 ))) 1294 1294 1295 1295 * ((( 1296 -Connect sensor ’s output to DI1-1449 +Connect sensor's output to DI1- 1297 1297 ))) 1298 1298 * ((( 1299 -Connect sensor ’s VCC to DI1+.1452 +Connect sensor's VCC to DI1+. 1300 1300 ))) 1301 1301 1302 1302 ((( ... ... @@ -1304,15 +1304,17 @@ 1304 1304 ))) 1305 1305 1306 1306 ((( 1307 -[[image:1653968155772-850.png||height="23" width="19"]]**= DI1+ 1460 +[[image:1653968155772-850.png||height="23" width="19"]]**= DI1**+** / 1K.** 1308 1308 ))) 1309 1309 1310 1310 ((( 1311 -If 1464 +If** DI1+ **= **12v**, the [[image:1653968155772-850.png||height="23" width="19"]]= 12mA , So the LT-22222-L will be able to detect this active signal. 1312 1312 ))) 1313 1313 1314 1314 ((( 1315 1315 1469 + 1470 + 1316 1316 ))) 1317 1317 1318 1318 ((( ... ... @@ -1324,10 +1324,10 @@ 1324 1324 ))) 1325 1325 1326 1326 * ((( 1327 -Connect sensor ’s output to DI1+1482 +Connect sensor's output to DI1+ 1328 1328 ))) 1329 1329 * ((( 1330 -Connect sensor ’s GND DI1-.1485 +Connect sensor's GND DI1-. 1331 1331 ))) 1332 1332 1333 1333 ((( ... ... @@ -1344,6 +1344,8 @@ 1344 1344 1345 1345 ((( 1346 1346 1502 + 1503 + 1347 1347 ))) 1348 1348 1349 1349 ((( ... ... @@ -1355,10 +1355,10 @@ 1355 1355 ))) 1356 1356 1357 1357 * ((( 1358 -Connect sensor ’s output to DI1+ with a serial 50K resistor1515 +Connect sensor's output to DI1+ with a serial 50K resistor 1359 1359 ))) 1360 1360 * ((( 1361 -Connect sensor ’s GND DI1-.1518 +Connect sensor's GND DI1-. 1362 1362 ))) 1363 1363 1364 1364 ((( ... ... @@ -1377,6 +1377,7 @@ 1377 1377 1378 1378 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1379 1379 1537 + 1380 1380 NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1381 1381 1382 1382 [[image:1653357531600-905.png]] ... ... @@ -1385,6 +1385,7 @@ 1385 1385 1386 1386 === 3.6.4 Analog Input Interface === 1387 1387 1546 + 1388 1388 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: 1389 1389 1390 1390 ... ... @@ -1416,6 +1416,7 @@ 1416 1416 1417 1417 === 3.6.5 Relay Output === 1418 1418 1578 + 1419 1419 ((( 1420 1420 The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1421 1421 ))) ... ... @@ -1422,6 +1422,7 @@ 1422 1422 1423 1423 [[image:image-20220524100215-9.png]] 1424 1424 1585 + 1425 1425 [[image:image-20220524100215-10.png||height="382" width="723"]] 1426 1426 1427 1427 ... ... @@ -1428,6 +1428,7 @@ 1428 1428 1429 1429 == 3.7 LEDs Indicators == 1430 1430 1592 + 1431 1431 [[image:image-20220524100748-11.png]] 1432 1432 1433 1433 ... ... @@ -1434,8 +1434,10 @@ 1434 1434 1435 1435 = 4. Use AT Command = 1436 1436 1599 + 1437 1437 == 4.1 Access AT Command == 1438 1438 1602 + 1439 1439 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1440 1440 1441 1441 [[image:1653358238933-385.png]] ... ... @@ -1640,6 +1640,7 @@ 1640 1640 1641 1641 == 4.2 Common AT Command Sequence == 1642 1642 1807 + 1643 1643 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1644 1644 1645 1645 ((( ... ... @@ -1750,6 +1750,8 @@ 1750 1750 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1751 1751 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1752 1752 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1918 + 1919 + 1753 1753 ))) 1754 1754 1755 1755 ((( ... ... @@ -1763,13 +1763,16 @@ 1763 1763 1764 1764 === 4.2.3 Change to Class A === 1765 1765 1933 + 1766 1766 If sensor JOINED 1767 1767 (% style="background-color:#dcdcdc" %)AT+CLASS=A 1768 1768 ATZ 1769 1769 1770 1770 1939 + 1771 1771 = 5. FAQ = 1772 1772 1942 + 1773 1773 == 5.1 How to upgrade the image? == 1774 1774 1775 1775 ... ... @@ -1786,12 +1786,14 @@ 1786 1786 1787 1787 ((( 1788 1788 (% style="color:blue" %)**Step1**(%%)**:** Download [[flash loader>>url:https://www.st.com/content/st_com/en/products/development-tools/software-development-tools/stm32-software-development-tools/stm32-programmers/flasher-stm32.html]]. 1789 -(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:http://www.dr agino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]].1959 +(% style="color:blue" %)**Step2**(%%)**:** Download the [[LT Image files>>url:https://www.dropbox.com/sh/g99v0fxcltn9r1y/AADKXQ2v5ZT-S3sxdmbvE7UAa/LT-22222-L/image?dl=0&subfolder_nav_tracking=1]]. 1790 1790 (% style="color:blue" %)**Step3**(%%)**:** Open flashloader; choose the correct COM port to update. 1791 1791 1792 1792 1793 1793 (% style="color:blue" %)**For LT-22222-L**(%%): 1794 1794 Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1965 + 1966 + 1795 1795 ))) 1796 1796 1797 1797 [[image:image-20220524103407-12.png]] ... ... @@ -1803,6 +1803,7 @@ 1803 1803 1804 1804 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1805 1805 1978 + 1806 1806 [[image:1653360054704-518.png||height="186" width="745"]] 1807 1807 1808 1808 ... ... @@ -1811,6 +1811,8 @@ 1811 1811 1812 1812 1813 1813 == 5.2 How to change the LoRa Frequency Bands/Region? == 1987 + 1988 + 1814 1814 ))) 1815 1815 ))) 1816 1816 ... ... @@ -1821,7 +1821,10 @@ 1821 1821 ((( 1822 1822 1823 1823 1999 + 1824 1824 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 2001 + 2002 + 1825 1825 ))) 1826 1826 1827 1827 ((( ... ... @@ -1834,25 +1834,33 @@ 1834 1834 ((( 1835 1835 Assume we have a LG02 working in the frequency 868400000 now , below is the step. 1836 1836 2015 + 1837 1837 1838 1838 ))) 1839 1839 ))) 1840 1840 1841 1841 ((( 1842 -(% style="color:#4f81bd" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 2021 +(% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 2022 + 2023 + 1843 1843 ))) 1844 1844 1845 1845 ((( 1846 1846 [[image:1653360231087-571.png||height="401" width="727"]] 2028 + 2029 + 1847 1847 ))) 1848 1848 1849 1849 ((( 1850 -(% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 2033 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.** 1851 1851 ))) 1852 1852 1853 1853 2037 + 1854 1854 ((( 1855 -(% style="color:#4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 2039 +(% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 2040 + 2041 + 1856 1856 ))) 1857 1857 1858 1858 ((( ... ... @@ -1876,16 +1876,21 @@ 1876 1876 [[image:1653360498588-932.png||height="485" width="726"]] 1877 1877 1878 1878 2065 + 1879 1879 == 5.4 Can I see counting event in Serial? == 1880 1880 2068 + 1881 1881 ((( 1882 -User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn ’t support AT+DEBUG. User can update to latest firmware first.2070 +User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 1883 1883 1884 1884 2073 + 1885 1885 == 5.5 Can i use point to point communication for LT-22222-L? == 1886 1886 2076 + 1887 1887 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1888 1888 2079 + 1889 1889 1890 1890 ))) 1891 1891 ... ... @@ -1892,6 +1892,7 @@ 1892 1892 ((( 1893 1893 == 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1894 1894 2086 + 1895 1895 If the device is not shut down, but directly powered off. 1896 1896 1897 1897 It will default that this is a power-off state. ... ... @@ -1901,12 +1901,25 @@ 1901 1901 After restart, the status before power failure will be read from flash. 1902 1902 1903 1903 2096 +== 5.7 Can i set up LT-22222-L as a NC(Normal Close) Relay? == 2097 + 2098 +LT-22222-L built-in relay is NO (Normal Open). User can use an external relay to achieve Normal Close purpose. Diagram as below: 2099 + 2100 +[[image:image-20221006170630-1.png||height="610" width="945"]] 2101 + 2102 + 2103 + 2104 + 1904 1904 = 6. Trouble Shooting = 2106 + 2107 + 1905 1905 ))) 1906 1906 1907 1907 ((( 1908 1908 ((( 1909 1909 == 6.1 Downlink doesn't work, how to solve it? == 2113 + 2114 + 1910 1910 ))) 1911 1911 ))) 1912 1912 ... ... @@ -1917,7 +1917,10 @@ 1917 1917 ((( 1918 1918 1919 1919 2125 + 1920 1920 == 6.2 Have trouble to upload image. == 2127 + 2128 + 1921 1921 ))) 1922 1922 1923 1923 ((( ... ... @@ -1927,7 +1927,10 @@ 1927 1927 ((( 1928 1928 1929 1929 2138 + 1930 1930 == 6.3 Why I can't join TTN in US915 /AU915 bands? == 2140 + 2141 + 1931 1931 ))) 1932 1932 1933 1933 ((( ... ... @@ -1935,6 +1935,7 @@ 1935 1935 ))) 1936 1936 1937 1937 2149 + 1938 1938 = 7. Order Info = 1939 1939 1940 1940 ... ... @@ -1952,6 +1952,7 @@ 1952 1952 * (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 1953 1953 * (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1954 1954 2167 + 1955 1955 = 8. Packing Info = 1956 1956 1957 1957 ... ... @@ -1969,18 +1969,24 @@ 1969 1969 * Package Size / pcs : 14.5 x 8 x 5 cm 1970 1970 * Weight / pcs : 170g 1971 1971 2185 + 1972 1972 = 9. Support = 1973 1973 2188 + 1974 1974 * ((( 1975 1975 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1976 1976 ))) 1977 1977 * ((( 1978 1978 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 2194 + 2195 + 2196 + 2197 + 1979 1979 ))) 1980 1980 1981 1981 = 10. Reference = 1982 1982 2202 + 1983 1983 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 1984 -* [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 1985 -* [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2204 +* [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 1986 1986 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]]
- image-20221006170630-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +486.5 KB - Content
- image-20221008095908-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +41.8 KB - Content