Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -179,6 +179,7 @@ 179 179 * Firmware upgradable via program port 180 180 * Counting 181 181 182 + 182 182 == 1.4 Applications == 183 183 184 184 * Smart Buildings & Home Automation ... ... @@ -188,6 +188,7 @@ 188 188 * Smart Cities 189 189 * Smart Factory 190 190 192 + 191 191 == 1.5 Hardware Variants == 192 192 193 193 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -201,6 +201,7 @@ 201 201 * 1 x Counting Port 202 202 ))) 203 203 206 + 204 204 = 2. Power ON Device = 205 205 206 206 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -274,13 +274,15 @@ 274 274 275 275 There are five working modes + one interrupt mode on LT for different type application: 276 276 277 -* (% style="color:blue" %) **MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO278 -* (% style="color:blue" %) **MOD2**(%%): Double DI Counting + DO + RO279 -* (% style="color:blue" %) **MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO280 -* (% style="color:blue" %) **MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO281 -* (% style="color:blue" %) **MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO282 -* (% style="color:blue" %) **ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5280 +* **(% style="color:blue" %)MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 281 +* **(% style="color:blue" %)MOD2**(%%): Double DI Counting + DO + RO 282 +* **(% style="color:blue" %)MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 283 +* **(% style="color:blue" %)MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 284 +* **(% style="color:blue" %)MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 285 +* **(% style="color:blue" %)ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 283 283 287 + 288 + 284 284 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 285 285 286 286 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -407,8 +407,6 @@ 407 407 [[image:image-20220523181246-5.png]] 408 408 409 409 ((( 410 - 411 - 412 412 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 413 413 ))) 414 414 ... ... @@ -422,7 +422,6 @@ 422 422 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 423 423 ))) 424 424 425 - 426 426 ((( 427 427 **To use counting mode, please run:** 428 428 ))) ... ... @@ -555,8 +555,8 @@ 555 555 556 556 For example, if user has configured below commands: 557 557 558 -* **AT+MOD=1 ** 559 -* **AT+ADDMOD6=1** **~-~->** 560 +* **AT+MOD=1 ** **~-~->** The normal working mode 561 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 560 560 561 561 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 562 562 ... ... @@ -565,7 +565,6 @@ 565 565 566 566 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 567 567 568 - 569 569 (% style="color:#4f81bd" %)**Trigger base on voltage**: 570 570 571 571 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -713,7 +713,6 @@ 713 713 714 714 === 3.4.2 Sensor related commands === 715 715 716 - 717 717 ==== 3.4.2.1 Set Transmit Interval ==== 718 718 719 719 Set device uplink interval. ... ... @@ -767,7 +767,6 @@ 767 767 768 768 769 769 770 - 771 771 ==== 3.4.2.4 Enable Trigger Mode ==== 772 772 773 773 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -924,7 +924,6 @@ 924 924 925 925 926 926 927 - 928 928 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 929 929 930 930 * (% style="color:#037691" %)**AT Command** ... ... @@ -1767,7 +1767,7 @@ 1767 1767 1768 1768 1769 1769 (% style="color:blue" %)**For LT-22222-L**(%%): 1770 -Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%)will change from OFF to ON. When(% style="color:red" %)**DO1 LED**(%%)is on, it means the device is in download mode.1768 +Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1771 1771 ))) 1772 1772 1773 1773 [[image:image-20220524103407-12.png]] ... ... @@ -1882,7 +1882,7 @@ 1882 1882 1883 1883 ((( 1884 1884 ((( 1885 -== 6.1 Downlink doesn 't work, how to solve it? ==1883 +== 6.1 Downlink doesn’t work, how to solve it? == 1886 1886 ))) 1887 1887 ))) 1888 1888 ... ... @@ -1903,7 +1903,7 @@ 1903 1903 ((( 1904 1904 1905 1905 1906 -== 6.3 Why I can 't join TTN in US915 /AU915 bands? ==1904 +== 6.3 Why I can’t join TTN in US915 /AU915 bands? == 1907 1907 ))) 1908 1908 1909 1909 ((( ... ... @@ -1913,25 +1913,21 @@ 1913 1913 1914 1914 = 7. Order Info = 1915 1915 1916 - 1917 1917 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1918 1918 1916 + 1919 1919 (% style="color:#4f81bd" %)**XXX:** 1920 1920 1921 -* (% style="color: red" %)**EU433**(%%):1922 -* (% style="color: red" %)**EU868**(%%):1923 -* (% style="color: red" %)**KR920**(%%):1924 -* (% style="color: red" %)**CN470**(%%):1925 -* (% style="color: red" %)**AS923**(%%):1926 -* (% style="color: red" %)**AU915**(%%):1927 -* (% style="color: red" %)**US915**(%%):1928 -* (% style="color: red" %)**IN865**(%%):1929 -* (% style="color: red" %)**CN779**(%%):1919 +* (% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433 1920 +* (% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868 1921 +* (% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920 1922 +* (% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470 1923 +* (% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923 1924 +* (% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915 1925 +* (% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915 1926 +* (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1927 +* (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1930 1930 1931 - 1932 - 1933 - 1934 - 1935 1935 = 8. Packing Info = 1936 1936 1937 1937 ... ... @@ -1949,10 +1949,6 @@ 1949 1949 * Package Size / pcs : 14.5 x 8 x 5 cm 1950 1950 * Weight / pcs : 170g 1951 1951 1952 - 1953 - 1954 - 1955 - 1956 1956 = 9. Support = 1957 1957 1958 1958 * ((( ... ... @@ -1960,10 +1960,11 @@ 1960 1960 ))) 1961 1961 * ((( 1962 1962 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1963 -))) 1964 1964 1965 1965 1966 1966 1956 + 1957 +))) 1967 1967 1968 1968 = 10. Reference = 1969 1969
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Bei - Size
-
... ... @@ -1,1 +1,0 @@ 1 -54.1 KB - Content