<
From version < 84.1 >
edited by Xiaoling
on 2022/06/29 18:01
To version < 82.42 >
edited by Xiaoling
on 2022/06/25 15:24
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,6 +1,7 @@
1 1  (% style="text-align:center" %)
2 2  [[image:image-20220523163353-1.jpeg||height="604" width="500"]]
3 3  
4 +**LT-22222-L LoRa IO Controller User Manual **
4 4  
5 5  
6 6  **Table of Contents:**
... ... @@ -166,6 +166,7 @@
166 166  Packet engine up to 256 bytes with CRC.
167 167  
168 168  
170 +
169 169  
170 170  )))
171 171  
... ... @@ -179,6 +179,9 @@
179 179  * Firmware upgradable via program port
180 180  * Counting
181 181  
184 +
185 +
186 +
182 182  == 1.4  Applications ==
183 183  
184 184  * Smart Buildings & Home Automation
... ... @@ -188,6 +188,9 @@
188 188  * Smart Cities
189 189  * Smart Factory
190 190  
196 +
197 +
198 +
191 191  == 1.5 Hardware Variants ==
192 192  
193 193  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -201,6 +201,7 @@
201 201  * 1 x Counting Port
202 202  )))
203 203  
212 +
204 204  = 2. Power ON Device =
205 205  
206 206  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -218,11 +218,11 @@
218 218  == 3.1 How it works? ==
219 219  
220 220  (((
221 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 
230 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 
222 222  )))
223 223  
224 224  (((
225 -In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
234 +In case user cant set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
226 226  )))
227 227  
228 228  
... ... @@ -274,13 +274,17 @@
274 274  
275 275  There are five working modes + one interrupt mode on LT for different type application:
276 276  
277 -* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
278 -* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO
279 -* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
280 -* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
281 -* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
282 -* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
286 +* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO
287 +* **MOD2**: Double DI Counting + DO + RO
288 +* **MOD3**: Single DI Counting + 2 x ACI + DO + RO
289 +* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO
290 +* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
291 +* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
283 283  
293 +
294 +
295 +
296 +
284 284  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
285 285  
286 286  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -334,6 +334,10 @@
334 334  ** DO1 is high in case there is load between DO1 and V+.
335 335  ** DO1 LED is off in both case
336 336  
350 +
351 +
352 +
353 +
337 337  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
338 338  
339 339  
... ... @@ -407,8 +407,6 @@
407 407  [[image:image-20220523181246-5.png]]
408 408  
409 409  (((
410 -
411 -
412 412  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
413 413  )))
414 414  
... ... @@ -422,7 +422,6 @@
422 422  (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
423 423  )))
424 424  
425 -
426 426  (((
427 427  **To use counting mode, please run:**
428 428  )))
... ... @@ -555,8 +555,8 @@
555 555  
556 556  For example, if user has configured below commands:
557 557  
558 -* **AT+MOD=1 ** **~-~->**  The normal working mode
559 -* **AT+ADDMOD6=1**   **~-~->**  Enable trigger
572 +* **AT+MOD=1 ** **~-~->** The normal working mode
573 +* **AT+ADDMOD6=1**   **~-~->** Enable trigger
560 560  
561 561  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
562 562  
... ... @@ -565,7 +565,6 @@
565 565  
566 566  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
567 567  
568 -
569 569  (% style="color:#4f81bd" %)**Trigger base on voltage**:
570 570  
571 571  Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH>
... ... @@ -705,6 +705,10 @@
705 705  
706 706  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
707 707  
721 +
722 +
723 +
724 +
708 708  === 3.4.1 Common Commands ===
709 709  
710 710  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -713,7 +713,6 @@
713 713  
714 714  === 3.4.2 Sensor related commands ===
715 715  
716 -
717 717  ==== 3.4.2.1 Set Transmit Interval ====
718 718  
719 719  Set device uplink interval.
... ... @@ -767,7 +767,6 @@
767 767  
768 768  
769 769  
770 -
771 771  ==== 3.4.2.4 Enable Trigger Mode ====
772 772  
773 773  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
... ... @@ -845,6 +845,7 @@
845 845  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
846 846  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
847 847  
863 +
848 848  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
849 849  
850 850  Set DI2 trigger.
... ... @@ -916,15 +916,9 @@
916 916  
917 917  **0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
918 918  
919 -(((
920 -
921 921  
922 -(% style="color:red" %)Note: ATDC setting must be more than 5min
923 -)))
924 924  
925 925  
926 -
927 -
928 928  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
929 929  
930 930  * (% style="color:#037691" %)**AT Command**
... ... @@ -1767,7 +1767,7 @@
1767 1767  
1768 1768  
1769 1769  (% style="color:blue" %)**For LT-22222-L**(%%):
1770 -Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode.
1780 +Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode.
1771 1771  )))
1772 1772  
1773 1773   [[image:image-20220524103407-12.png]]
... ... @@ -1882,7 +1882,7 @@
1882 1882  
1883 1883  (((
1884 1884  (((
1885 -== 6.1 Downlink doesn't work, how to solve it? ==
1895 +== 6.1 Downlink doesnt work, how to solve it? ==
1886 1886  )))
1887 1887  )))
1888 1888  
... ... @@ -1903,7 +1903,7 @@
1903 1903  (((
1904 1904  
1905 1905  
1906 -== 6.3 Why I can't join TTN in US915 /AU915 bands? ==
1916 +== 6.3 Why I cant join TTN in US915 /AU915 bands? ==
1907 1907  )))
1908 1908  
1909 1909  (((
... ... @@ -1913,25 +1913,22 @@
1913 1913  
1914 1914  = 7. Order Info =
1915 1915  
1916 -
1917 1917  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
1918 1918  
1928 +
1919 1919  (% style="color:#4f81bd" %)**XXX:**
1920 1920  
1921 -* (% style="color:red" %)**EU433**(%%):  LT with frequency bands EU433
1922 -* (% style="color:red" %)**EU868**(%%):  LT with frequency bands EU868
1923 -* (% style="color:red" %)**KR920**(%%):  LT with frequency bands KR920
1924 -* (% style="color:red" %)**CN470**(%%):  LT with frequency bands CN470
1925 -* (% style="color:red" %)**AS923**(%%):  LT with frequency bands AS923
1926 -* (% style="color:red" %)**AU915**(%%):  LT with frequency bands AU915
1927 -* (% style="color:red" %)**US915**(%%):  LT with frequency bands US915
1928 -* (% style="color:red" %)**IN865**(%%):  LT with frequency bands IN865
1929 -* (% style="color:red" %)**CN779**(%%):  LT with frequency bands CN779
1931 +* (% style="color:#4f81bd" %)**EU433**(%%): LT with frequency bands EU433
1932 +* (% style="color:#4f81bd" %)**EU868**(%%): LT with frequency bands EU868
1933 +* (% style="color:#4f81bd" %)**KR920**(%%): LT with frequency bands KR920
1934 +* (% style="color:#4f81bd" %)**CN470**(%%): LT with frequency bands CN470
1935 +* (% style="color:#4f81bd" %)**AS923**(%%): LT with frequency bands AS923
1936 +* (% style="color:#4f81bd" %)**AU915**(%%): LT with frequency bands AU915
1937 +* (% style="color:#4f81bd" %)**US915**(%%): LT with frequency bands US915
1938 +* (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1939 +* (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1930 1930  
1931 1931  
1932 -
1933 -
1934 -
1935 1935  = 8. Packing Info =
1936 1936  
1937 1937  
... ... @@ -1950,9 +1950,6 @@
1950 1950  * Weight / pcs : 170g
1951 1951  
1952 1952  
1953 -
1954 -
1955 -
1956 1956  = 9. Support =
1957 1957  
1958 1958  * (((
... ... @@ -1960,10 +1960,11 @@
1960 1960  )))
1961 1961  * (((
1962 1962  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1963 -)))
1964 1964  
1965 1965  
1966 1966  
1970 +
1971 +)))
1967 1967  
1968 1968  = 10. Reference​​​​​ =
1969 1969  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0