Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,7 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 +**LT-22222-L LoRa IO Controller User Manual ** 4 4 5 5 6 6 **Table of Contents:** ... ... @@ -166,6 +166,7 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 170 + 169 169 170 170 ))) 171 171 ... ... @@ -201,6 +201,8 @@ 201 201 * 1 x Counting Port 202 202 ))) 203 203 206 + 207 + 204 204 = 2. Power ON Device = 205 205 206 206 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -218,11 +218,11 @@ 218 218 == 3.1 How it works? == 219 219 220 220 ((( 221 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%)will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network.(% style="color:green" %)**TX LED**(%%)will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second.225 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 222 222 ))) 223 223 224 224 ((( 225 -In case user can 't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.229 +In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 226 226 ))) 227 227 228 228 ... ... @@ -274,15 +274,13 @@ 274 274 275 275 There are five working modes + one interrupt mode on LT for different type application: 276 276 277 -* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO278 -* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO279 -* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO280 -* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO281 -* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO282 -* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5281 +* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 282 +* **MOD2**: Double DI Counting + DO + RO 283 +* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 284 +* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 285 +* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 +* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 283 283 284 - 285 - 286 286 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 287 287 288 288 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -321,8 +321,6 @@ 321 321 * [1] RO1 relay channel is close and the RO1 LED is ON. 322 322 * [0] RO2 relay channel is open and RO2 LED is OFF; 323 323 324 - 325 - 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -338,8 +338,6 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 341 - 342 - 343 343 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 344 344 345 345 ... ... @@ -413,8 +413,6 @@ 413 413 [[image:image-20220523181246-5.png]] 414 414 415 415 ((( 416 - 417 - 418 418 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 419 419 ))) 420 420 ... ... @@ -428,7 +428,6 @@ 428 428 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 429 429 ))) 430 430 431 - 432 432 ((( 433 433 **To use counting mode, please run:** 434 434 ))) ... ... @@ -561,8 +561,8 @@ 561 561 562 562 For example, if user has configured below commands: 563 563 564 -* **AT+MOD=1 ** 565 -* **AT+ADDMOD6=1** **~-~->** 559 +* **AT+MOD=1 ** **~-~->** The normal working mode 560 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 566 566 567 567 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 568 568 ... ... @@ -569,6 +569,7 @@ 569 569 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 570 570 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 571 571 567 + 572 572 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 573 573 574 574 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -802,7 +802,7 @@ 802 802 803 803 * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 804 804 805 -**0xAB 06 801 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 806 806 807 807 808 808 ... ... @@ -848,6 +848,9 @@ 848 848 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 849 849 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 850 850 847 + 848 + 849 + 851 851 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 852 852 853 853 Set DI2 trigger. ... ... @@ -912,7 +912,7 @@ 912 912 913 913 * (% style="color:#037691" %)**AT Command** 914 914 915 -**AT+ATDC=5 914 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 916 916 917 917 918 918 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -919,14 +919,9 @@ 919 919 920 920 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 921 921 922 -((( 923 - 924 924 925 -(% style="color:red" %)Note: ATDC setting must be more than 5min 926 -))) 927 927 928 928 929 - 930 930 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 931 931 932 932 * (% style="color:#037691" %)**AT Command** ... ... @@ -1151,7 +1151,7 @@ 1151 1151 1152 1152 * (% style="color:#037691" %)**AT Command:** 1153 1153 1154 -**AT+CLRCOUNT ** ~/~/ clear all counting 1148 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1155 1155 1156 1156 1157 1157 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1409,7 +1409,6 @@ 1409 1409 [[image:image-20220524100748-11.png]] 1410 1410 1411 1411 1412 - 1413 1413 = 4. Use AT Command = 1414 1414 1415 1415 == 4.1 Access AT Command == ... ... @@ -1612,6 +1612,8 @@ 1612 1612 1613 1613 ((( 1614 1614 AT+CFG: Print all settings 1608 + 1609 + 1615 1615 ))) 1616 1616 1617 1617 ... ... @@ -1657,6 +1657,8 @@ 1657 1657 1658 1658 ((( 1659 1659 (% style="background-color:#dcdcdc" %)ATZ 1655 + 1656 + 1660 1660 ))) 1661 1661 1662 1662 ... ... @@ -1863,8 +1863,6 @@ 1863 1863 == 5.5 Can i use point to point communication for LT-22222-L? == 1864 1864 1865 1865 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1866 - 1867 - 1868 1868 ))) 1869 1869 1870 1870 ((( ... ... @@ -1878,7 +1878,6 @@ 1878 1878 1879 1879 After restart, the status before power failure will be read from flash. 1880 1880 1881 - 1882 1882 = 6. Trouble Shooting = 1883 1883 ))) 1884 1884 ... ... @@ -1913,8 +1913,10 @@ 1913 1913 ))) 1914 1914 1915 1915 1910 + 1916 1916 = 7. Order Info = 1917 1917 1913 + 1918 1918 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1919 1919 1920 1920 ... ... @@ -1954,10 +1954,6 @@ 1954 1954 ))) 1955 1955 * ((( 1956 1956 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1957 - 1958 - 1959 - 1960 - 1961 1961 ))) 1962 1962 1963 1963 = 10. Reference =