Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Bei - Content
-
... ... @@ -36,11 +36,13 @@ 36 36 ))) 37 37 38 38 ((( 39 -1) If user ’s area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.39 +1) If user's area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless. 40 40 ))) 41 41 42 42 ((( 43 43 2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless. 44 + 45 + 44 44 ))) 45 45 46 46 ((( ... ... @@ -166,21 +166,25 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 171 + 169 169 170 170 ))) 171 171 172 172 == 1.3 Features == 173 173 177 + 174 174 * LoRaWAN Class A & Class C protocol 175 175 * Optional Customized LoRa Protocol 176 -* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 180 +* Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865/MA869 177 177 * AT Commands to change parameters 178 178 * Remote configure parameters via LoRa Downlink 179 179 * Firmware upgradable via program port 180 180 * Counting 181 181 186 + 182 182 == 1.4 Applications == 183 183 189 + 184 184 * Smart Buildings & Home Automation 185 185 * Logistics and Supply Chain Management 186 186 * Smart Metering ... ... @@ -188,8 +188,10 @@ 188 188 * Smart Cities 189 189 * Smart Factory 190 190 197 + 191 191 == 1.5 Hardware Variants == 192 192 200 + 193 193 (% border="1" style="background-color:#f7faff; width:500px" %) 194 194 |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 195 195 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( ... ... @@ -203,6 +203,7 @@ 203 203 204 204 = 2. Power ON Device = 205 205 214 + 206 206 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 207 207 208 208 ((( ... ... @@ -217,6 +217,7 @@ 217 217 218 218 == 3.1 How it works? == 219 219 229 + 220 220 ((( 221 221 The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 222 222 ))) ... ... @@ -226,10 +226,14 @@ 226 226 ))) 227 227 228 228 239 + 229 229 == 3.2 Example to join LoRaWAN network == 230 230 242 + 231 231 ((( 232 232 This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 245 + 246 + 233 233 ))) 234 234 235 235 [[image:image-20220523172350-1.png||height="266" width="864"]] ... ... @@ -237,6 +237,8 @@ 237 237 238 238 ((( 239 239 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 254 + 255 + 240 240 ))) 241 241 242 242 ((( ... ... @@ -262,6 +262,7 @@ 262 262 [[image:1653298023685-319.png]] 263 263 264 264 281 + 265 265 ((( 266 266 (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 267 267 ))) ... ... @@ -272,6 +272,7 @@ 272 272 273 273 == 3.3 Uplink Payload == 274 274 292 + 275 275 There are five working modes + one interrupt mode on LT for different type application: 276 276 277 277 * (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO ... ... @@ -282,9 +282,9 @@ 282 282 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 283 283 284 284 285 - 286 286 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 287 287 305 + 288 288 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 289 289 290 290 [[image:image-20220523174024-3.png]] ... ... @@ -321,8 +321,6 @@ 321 321 * [1] RO1 relay channel is close and the RO1 LED is ON. 322 322 * [0] RO2 relay channel is open and RO2 LED is OFF; 323 323 324 - 325 - 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -339,7 +339,6 @@ 339 339 ** DO1 LED is off in both case 340 340 341 341 342 - 343 343 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 344 344 345 345 ... ... @@ -408,6 +408,7 @@ 408 408 409 409 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 410 410 426 + 411 411 **LT22222-L**: This mode the DI1 is used as a counting pin. 412 412 413 413 [[image:image-20220523181246-5.png]] ... ... @@ -571,6 +571,7 @@ 571 571 572 572 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 573 573 590 + 574 574 (% style="color:#4f81bd" %)**Trigger base on voltage**: 575 575 576 576 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -692,14 +692,14 @@ 692 692 ((( 693 693 694 694 695 -**Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 696 - 697 - 712 +**Decoder for TTN/loraserver/ChirpStack**: [[https:~~/~~/www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0>>https://www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0]] 698 698 ))) 699 699 700 700 716 + 701 701 == 3.4 Configure LT via AT or Downlink == 702 702 719 + 703 703 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 704 704 705 705 ((( ... ... @@ -712,6 +712,7 @@ 712 712 713 713 === 3.4.1 Common Commands === 714 714 732 + 715 715 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 716 716 717 717 ... ... @@ -718,8 +718,10 @@ 718 718 719 719 === 3.4.2 Sensor related commands === 720 720 739 + 721 721 ==== 3.4.2.1 Set Transmit Interval ==== 722 722 742 + 723 723 Set device uplink interval. 724 724 725 725 * (% style="color:#037691" %)**AT Command:** ... ... @@ -739,6 +739,7 @@ 739 739 740 740 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 741 741 762 + 742 742 Set work mode. 743 743 744 744 * (% style="color:#037691" %)**AT Command:** ... ... @@ -758,6 +758,7 @@ 758 758 759 759 ==== 3.4.2.3 Poll an uplink ==== 760 760 782 + 761 761 * (% style="color:#037691" %)**AT Command:** 762 762 763 763 There is no AT Command to poll uplink ... ... @@ -771,8 +771,10 @@ 771 771 772 772 773 773 796 + 774 774 ==== 3.4.2.4 Enable Trigger Mode ==== 775 775 799 + 776 776 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 777 777 778 778 * (% style="color:#037691" %)**AT Command:** ... ... @@ -793,6 +793,7 @@ 793 793 794 794 ==== 3.4.2.5 Poll trigger settings ==== 795 795 820 + 796 796 Poll trigger settings, 797 797 798 798 * (% style="color:#037691" %)**AT Command:** ... ... @@ -809,6 +809,7 @@ 809 809 810 810 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 811 811 837 + 812 812 Enable Disable DI1/DI2/DI2 as trigger, 813 813 814 814 * (% style="color:#037691" %)**AT Command:** ... ... @@ -829,6 +829,7 @@ 829 829 830 830 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 831 831 858 + 832 832 Set DI1 or DI3(for LT-33222-L) trigger. 833 833 834 834 * (% style="color:#037691" %)**AT Command:** ... ... @@ -848,8 +848,10 @@ 848 848 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 849 849 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 850 850 878 + 851 851 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 852 852 881 + 853 853 Set DI2 trigger. 854 854 855 855 * (% style="color:#037691" %)**AT Command:** ... ... @@ -876,6 +876,7 @@ 876 876 877 877 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 878 878 908 + 879 879 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 880 880 881 881 * (% style="color:#037691" %)**AT Command** ... ... @@ -892,6 +892,7 @@ 892 892 893 893 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 894 894 925 + 895 895 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 896 896 897 897 * (% style="color:#037691" %)**AT Command** ... ... @@ -908,6 +908,7 @@ 908 908 909 909 ==== 3.4.2.11 Trigger – Set minimum interval ==== 910 910 942 + 911 911 Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 912 912 913 913 * (% style="color:#037691" %)**AT Command** ... ... @@ -927,8 +927,10 @@ 927 927 928 928 929 929 962 + 930 930 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 931 931 965 + 932 932 * (% style="color:#037691" %)**AT Command** 933 933 934 934 There is no AT Command to control Digital Output ... ... @@ -960,6 +960,7 @@ 960 960 961 961 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 962 962 997 + 963 963 * (% style="color:#037691" %)**AT Command** 964 964 965 965 There is no AT Command to control Digital Output ... ... @@ -996,7 +996,7 @@ 996 996 [[image:image-20220524093351-8.png]] 997 997 998 998 999 -(% style="color:#4f81bd" %)**Sixth and Seventh Byte**: 1034 +(% style="color:#4f81bd" %)**Sixth and Seventh and Eighth and Ninth Byte**: 1000 1000 1001 1001 Latching time. Unit: ms 1002 1002 ... ... @@ -1021,11 +1021,13 @@ 1021 1021 1022 1022 DO1 pin no action, DO2 pin set low, DO3 pin set high, last 2 seconds, then DO1 pin no action, DO2 pin set high, DO3 pin set low 1023 1023 1059 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully. 1024 1024 1025 1025 1026 1026 1027 1027 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1028 1028 1065 + 1029 1029 * (% style="color:#037691" %)**AT Command:** 1030 1030 1031 1031 There is no AT Command to control Relay Output ... ... @@ -1048,7 +1048,7 @@ 1048 1048 [[image:image-20220524093724-9.png]] 1049 1049 ))) 1050 1050 1051 -Device will upload a packet if downlink code executes successfully. 1088 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully. 1052 1052 1053 1053 1054 1054 ... ... @@ -1055,6 +1055,7 @@ 1055 1055 1056 1056 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1057 1057 1095 + 1058 1058 * (% style="color:#037691" %)**AT Command:** 1059 1059 1060 1060 There is no AT Command to control Relay Output ... ... @@ -1078,10 +1078,10 @@ 1078 1078 1079 1079 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1080 1080 1081 -[[image:image-20220 524093831-10.png]]1119 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1082 1082 1083 1083 1084 -(% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms 1122 +(% style="color:#4f81bd" %)**Fourth/Fifth/Sixth/Seventh Bytes(cc)**(%%): Latching time. Unit: ms 1085 1085 1086 1086 Device will upload a packet if downlink code executes successfully. 1087 1087 ... ... @@ -1088,27 +1088,29 @@ 1088 1088 1089 1089 **Example payload:** 1090 1090 1091 -**~1. 05 01 11 07 D 0**1129 +**~1. 05 01 11 07 D** 1092 1092 1093 -Relay1 and Relay 2 will be set to N O, last 2 seconds, then change back to original state.1131 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1094 1094 1095 1095 **2. 05 01 10 07 D0** 1096 1096 1097 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then both change back to original state.1135 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state. 1098 1098 1099 1099 **3. 05 00 01 07 D0** 1100 1100 1101 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then relay change to NO,C.1139 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO. 1102 1102 1103 1103 **4. 05 00 00 07 D0** 1104 1104 1105 -Relay 1 & relay2 will change to N C, last 2 seconds, then both change to NO.1143 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC. 1106 1106 1145 +(% style="color:red" %)Device will upload a packet if downlink code executes successfully. 1107 1107 1108 1108 1109 1109 1110 1110 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1111 1111 1151 + 1112 1112 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1113 1113 1114 1114 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1125,6 +1125,7 @@ 1125 1125 1126 1126 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1127 1127 1168 + 1128 1128 * (% style="color:#037691" %)**AT Command:** 1129 1129 1130 1130 **AT+SETCNT=aa,(bb cc dd ee) ** ... ... @@ -1147,6 +1147,7 @@ 1147 1147 1148 1148 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1149 1149 1191 + 1150 1150 Clear counting for counting mode 1151 1151 1152 1152 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1163,6 +1163,7 @@ 1163 1163 1164 1164 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1165 1165 1208 + 1166 1166 * (% style="color:#037691" %)**AT Command:** 1167 1167 1168 1168 **AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) ... ... @@ -1178,10 +1178,97 @@ 1178 1178 1179 1179 ))) 1180 1180 1224 +==== 3.4.2.20 Reset save DR DO state ==== 1181 1181 1226 +* (% style="color:#037691" %)**AT Command:** 1182 1182 1228 +**AT+RODORET=1 **~/~/ RODO will close when the device joining the network. (default) 1229 + 1230 +**AT+RODORET=0 **~/~/After the device is reset, the previously saved RODO state (only MOD2 to MOD5) is read, and its state is not changed when it is reconnected to the network. 1231 + 1232 + 1233 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAD):** 1234 + 1235 +**0x AD aa **~/~/ same as AT+RODORET =aa 1236 + 1237 +((( 1238 + 1239 + 1240 +==== 3.4.2.21 Encrypted payload ==== 1241 + 1242 +* (% style="color:#037691" %)**AT Command:** 1243 + 1244 +**AT+DECRYPT=1 **~/~/ The payload is uploaded without encryption 1245 + 1246 +**AT+DECRYPT=0 **~/~/Encrypt when uploading payload (default) 1247 + 1248 + 1249 +==== 3.4.2.22 Get sensor value ==== 1250 + 1251 +* (% style="color:#037691" %)**AT Command:** 1252 + 1253 +**AT+GETSENSORVALUE=0 **~/~/ The serial port gets the reading of the current sensor 1254 + 1255 +**AT+GETSENSORVALUE=1 **~/~/The serial port gets the current sensor reading and uploads it. 1256 + 1257 + 1258 +==== 3.4.2.23 Resets the downlink packet count ==== 1259 + 1260 +* (% style="color:#037691" %)**AT Command:** 1261 + 1262 +**AT+DISFCNTCHECK=0 **~/~/ When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node will no longer receive downlink packets (default) 1263 + 1264 +**AT+DISFCNTCHECK=1 **~/~/When the downlink packet count sent by the server is less than the node downlink packet count or exceeds 16384, the node resets the downlink packet count and keeps it consistent with the server downlink packet count. 1265 + 1266 + 1267 +==== 3.4.2.24 When the limit bytes are exceeded, upload in batches ==== 1268 + 1269 +* (% style="color:#037691" %)**AT Command:** 1270 + 1271 + **AT+DISMACANS=0** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of 11 bytes (DR0 of US915, DR2 of AS923, DR2 of AU195), the node will send a packet with a payload of 00 and a port of 4. (default) 1272 + 1273 + **AT+DISMACANS=1** ~/~/ When the MACANS of the reply server plus the payload exceeds the maximum number of bytes of the DR, the node will ignore the MACANS and not reply, and only upload the payload part. 1274 + 1275 + 1276 +* (% style="color:#037691" %)**Downlink Payload **(%%)**:** 1277 + 1278 +**0x21 00 01 ** ~/~/ Set the DISMACANS=1 1279 + 1280 +==== 3.4.2.25 Copy downlink to uplink ==== 1281 + 1282 +* (% style="color:#037691" %)**AT Command**(%%)**:** 1283 + 1284 + **AT+RPL=5** ~/~/ After receiving the package from the server, it will immediately upload the content of the package to the server, the port number is 100. 1285 + 1286 +Example:**aa xx xx xx xx** ~/~/ aa indicates whether the configuration has changed, 00 is yes, 01 is no; xx xx xx xx are the bytes sent. 1287 + 1288 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173747-6.png?width=1124&height=165&rev=1.1||alt="image-20220823173747-6.png"]] 1289 + 1290 +For example, sending 11 22 33 44 55 66 77 will return invalid configuration 00 11 22 33 44 55 66 77. 1291 + 1292 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173833-7.png?width=1124&height=149&rev=1.1||alt="image-20220823173833-7.png"]] 1293 + 1294 +For example, if 01 00 02 58 is issued, a valid configuration of 01 01 00 02 58 will be returned. 1295 + 1296 + 1297 + 1298 +==== 3.4.2.26 Query version number and frequency band 、TDC ==== 1299 + 1300 +* ((( 1301 +(% style="color:#037691" %)**Downlink Payload**(%%)**: 26 01 ** ~/~/ Downlink 26 01 can query device upload frequency, frequency band, software version number, TDC time. 1302 +))) 1303 + 1304 +Example: 1305 + 1306 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/LSN50%20%26%20LSN50-V2%20-%20LoRaWAN%20Sensor%20Node%20User%20Manual/WebHome/image-20220823173929-8.png?width=1205&height=76&rev=1.1||alt="image-20220823173929-8.png"]] 1307 + 1308 + 1309 + 1310 +))) 1311 + 1183 1183 == 3.5 Integrate with Mydevice == 1184 1184 1314 + 1185 1185 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: 1186 1186 1187 1187 ((( ... ... @@ -1190,14 +1190,15 @@ 1190 1190 1191 1191 ((( 1192 1192 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1323 + 1324 + 1193 1193 ))) 1194 1194 1195 -[[image:1 653356737703-362.png||height="232" width="732"]]1327 +[[image:image-20220719105525-1.png||height="377" width="677"]] 1196 1196 1197 -[[image:image-20220524094641-11.png||height="390" width="723"]] 1198 1198 1199 1199 1200 -[[image:image-20220 524094641-12.png||height="402" width="718"]]1331 +[[image:image-20220719110247-2.png||height="388" width="683"]] 1201 1201 1202 1202 1203 1203 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. ... ... @@ -1230,8 +1230,10 @@ 1230 1230 1231 1231 == 3.6 Interface Detail == 1232 1232 1364 + 1233 1233 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1234 1234 1367 + 1235 1235 Support NPN Type sensor 1236 1236 1237 1237 [[image:1653356991268-289.png]] ... ... @@ -1240,6 +1240,7 @@ 1240 1240 1241 1241 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1242 1242 1376 + 1243 1243 ((( 1244 1244 The DI port of LT-22222-L can support NPN or PNP output sensor. 1245 1245 ))) ... ... @@ -1246,7 +1246,9 @@ 1246 1246 1247 1247 ((( 1248 1248 ((( 1249 -Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high 1383 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high. 1384 + 1385 + 1250 1250 ))) 1251 1251 ))) 1252 1252 ... ... @@ -1291,6 +1291,8 @@ 1291 1291 1292 1292 ((( 1293 1293 1430 + 1431 + 1294 1294 ))) 1295 1295 1296 1296 ((( ... ... @@ -1322,6 +1322,8 @@ 1322 1322 1323 1323 ((( 1324 1324 1463 + 1464 + 1325 1325 ))) 1326 1326 1327 1327 ((( ... ... @@ -1355,6 +1355,7 @@ 1355 1355 1356 1356 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1357 1357 1498 + 1358 1358 NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1359 1359 1360 1360 [[image:1653357531600-905.png]] ... ... @@ -1363,6 +1363,7 @@ 1363 1363 1364 1364 === 3.6.4 Analog Input Interface === 1365 1365 1507 + 1366 1366 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: 1367 1367 1368 1368 ... ... @@ -1394,6 +1394,7 @@ 1394 1394 1395 1395 === 3.6.5 Relay Output === 1396 1396 1539 + 1397 1397 ((( 1398 1398 The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1399 1399 ))) ... ... @@ -1406,6 +1406,7 @@ 1406 1406 1407 1407 == 3.7 LEDs Indicators == 1408 1408 1552 + 1409 1409 [[image:image-20220524100748-11.png]] 1410 1410 1411 1411 ... ... @@ -1412,8 +1412,10 @@ 1412 1412 1413 1413 = 4. Use AT Command = 1414 1414 1559 + 1415 1415 == 4.1 Access AT Command == 1416 1416 1562 + 1417 1417 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1418 1418 1419 1419 [[image:1653358238933-385.png]] ... ... @@ -1618,6 +1618,7 @@ 1618 1618 1619 1619 == 4.2 Common AT Command Sequence == 1620 1620 1767 + 1621 1621 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1622 1622 1623 1623 ((( ... ... @@ -1728,6 +1728,8 @@ 1728 1728 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1729 1729 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1730 1730 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1878 + 1879 + 1731 1731 ))) 1732 1732 1733 1733 ((( ... ... @@ -1741,13 +1741,16 @@ 1741 1741 1742 1742 === 4.2.3 Change to Class A === 1743 1743 1893 + 1744 1744 If sensor JOINED 1745 1745 (% style="background-color:#dcdcdc" %)AT+CLASS=A 1746 1746 ATZ 1747 1747 1748 1748 1899 + 1749 1749 = 5. FAQ = 1750 1750 1902 + 1751 1751 == 5.1 How to upgrade the image? == 1752 1752 1753 1753 ... ... @@ -1769,7 +1769,9 @@ 1769 1769 1770 1770 1771 1771 (% style="color:blue" %)**For LT-22222-L**(%%): 1772 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1924 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1925 + 1926 + 1773 1773 ))) 1774 1774 1775 1775 [[image:image-20220524103407-12.png]] ... ... @@ -1781,6 +1781,7 @@ 1781 1781 1782 1782 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1783 1783 1938 + 1784 1784 [[image:1653360054704-518.png||height="186" width="745"]] 1785 1785 1786 1786 ... ... @@ -1789,6 +1789,8 @@ 1789 1789 1790 1790 1791 1791 == 5.2 How to change the LoRa Frequency Bands/Region? == 1947 + 1948 + 1792 1792 ))) 1793 1793 ))) 1794 1794 ... ... @@ -1799,7 +1799,10 @@ 1799 1799 ((( 1800 1800 1801 1801 1959 + 1802 1802 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 1961 + 1962 + 1803 1803 ))) 1804 1804 1805 1805 ((( ... ... @@ -1817,7 +1817,7 @@ 1817 1817 ))) 1818 1818 1819 1819 ((( 1820 -(% style="color: #4f81bd" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.1980 +(% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 1821 1821 ))) 1822 1822 1823 1823 ((( ... ... @@ -1825,12 +1825,12 @@ 1825 1825 ))) 1826 1826 1827 1827 ((( 1828 -(% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 1988 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.** 1829 1829 ))) 1830 1830 1831 1831 1832 1832 ((( 1833 -(% style="color: #4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:1993 +(% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 1834 1834 ))) 1835 1835 1836 1836 ((( ... ... @@ -1854,16 +1854,21 @@ 1854 1854 [[image:1653360498588-932.png||height="485" width="726"]] 1855 1855 1856 1856 2017 + 1857 1857 == 5.4 Can I see counting event in Serial? == 1858 1858 2020 + 1859 1859 ((( 1860 -User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn ’t support AT+DEBUG. User can update to latest firmware first.2022 +User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 1861 1861 1862 1862 2025 + 1863 1863 == 5.5 Can i use point to point communication for LT-22222-L? == 1864 1864 2028 + 1865 1865 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1866 1866 2031 + 1867 1867 1868 1868 ))) 1869 1869 ... ... @@ -1870,6 +1870,7 @@ 1870 1870 ((( 1871 1871 == 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1872 1872 2038 + 1873 1873 If the device is not shut down, but directly powered off. 1874 1874 1875 1875 It will default that this is a power-off state. ... ... @@ -1879,12 +1879,15 @@ 1879 1879 After restart, the status before power failure will be read from flash. 1880 1880 1881 1881 2048 + 1882 1882 = 6. Trouble Shooting = 1883 1883 ))) 1884 1884 1885 1885 ((( 1886 1886 ((( 1887 -== 6.1 Downlink doesn’t work, how to solve it? == 2054 +== 6.1 Downlink doesn't work, how to solve it? == 2055 + 2056 + 1888 1888 ))) 1889 1889 ))) 1890 1890 ... ... @@ -1895,7 +1895,10 @@ 1895 1895 ((( 1896 1896 1897 1897 2067 + 1898 1898 == 6.2 Have trouble to upload image. == 2069 + 2070 + 1899 1899 ))) 1900 1900 1901 1901 ((( ... ... @@ -1905,7 +1905,10 @@ 1905 1905 ((( 1906 1906 1907 1907 1908 -== 6.3 Why I can’t join TTN in US915 /AU915 bands? == 2080 + 2081 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 2082 + 2083 + 1909 1909 ))) 1910 1910 1911 1911 ((( ... ... @@ -1913,22 +1913,23 @@ 1913 1913 ))) 1914 1914 1915 1915 2091 + 1916 1916 = 7. Order Info = 1917 1917 2094 + 1918 1918 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1919 1919 1920 - 1921 1921 (% style="color:#4f81bd" %)**XXX:** 1922 1922 1923 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331924 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681925 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201926 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701927 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231928 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151929 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151930 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651931 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7792099 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 2100 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 2101 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 2102 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 2103 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 2104 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 2105 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 2106 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2107 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1932 1932 1933 1933 = 8. Packing Info = 1934 1934 ... ... @@ -1949,6 +1949,7 @@ 1949 1949 1950 1950 = 9. Support = 1951 1951 2128 + 1952 1952 * ((( 1953 1953 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1954 1954 ))) ... ... @@ -1962,7 +1962,9 @@ 1962 1962 1963 1963 = 10. Reference = 1964 1964 2142 + 1965 1965 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 1966 -* [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 1967 -* [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2144 +* [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 1968 1968 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2146 + 2147 +
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.9 KB - Content