<
From version < 83.7 >
edited by Xiaoling
on 2022/06/29 17:28
To version < 83.3 >
edited by Xiaoling
on 2022/06/29 17:17
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -179,6 +179,8 @@
179 179  * Firmware upgradable via program port
180 180  * Counting
181 181  
182 +
183 +
182 182  == 1.4  Applications ==
183 183  
184 184  * Smart Buildings & Home Automation
... ... @@ -188,6 +188,8 @@
188 188  * Smart Cities
189 189  * Smart Factory
190 190  
193 +
194 +
191 191  == 1.5 Hardware Variants ==
192 192  
193 193  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -201,6 +201,8 @@
201 201  * 1 x Counting Port
202 202  )))
203 203  
208 +
209 +
204 204  = 2. Power ON Device =
205 205  
206 206  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -218,11 +218,11 @@
218 218  == 3.1 How it works? ==
219 219  
220 220  (((
221 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 
227 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 
222 222  )))
223 223  
224 224  (((
225 -In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
231 +In case user cant set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
226 226  )))
227 227  
228 228  
... ... @@ -274,15 +274,14 @@
274 274  
275 275  There are five working modes + one interrupt mode on LT for different type application:
276 276  
277 -* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
278 -* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO
279 -* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
280 -* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
281 -* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
282 -* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
283 +* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO
284 +* **MOD2**: Double DI Counting + DO + RO
285 +* **MOD3**: Single DI Counting + 2 x ACI + DO + RO
286 +* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO
287 +* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
288 +* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
283 283  
284 284  
285 -
286 286  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
287 287  
288 288  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -321,8 +321,6 @@
321 321  * [1] RO1 relay channel is close and the RO1 LED is ON.
322 322  * [0] RO2 relay channel is open and RO2 LED is OFF;
323 323  
324 -
325 -
326 326  **LT22222-L:**
327 327  
328 328  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -339,7 +339,6 @@
339 339  ** DO1 LED is off in both case
340 340  
341 341  
342 -
343 343  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
344 344  
345 345  
... ... @@ -413,8 +413,6 @@
413 413  [[image:image-20220523181246-5.png]]
414 414  
415 415  (((
416 -
417 -
418 418  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
419 419  )))
420 420  
... ... @@ -428,7 +428,6 @@
428 428  (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
429 429  )))
430 430  
431 -
432 432  (((
433 433  **To use counting mode, please run:**
434 434  )))
... ... @@ -561,8 +561,8 @@
561 561  
562 562  For example, if user has configured below commands:
563 563  
564 -* **AT+MOD=1 ** **~-~->**  The normal working mode
565 -* **AT+ADDMOD6=1**   **~-~->**  Enable trigger
563 +* **AT+MOD=1 ** **~-~->** The normal working mode
564 +* **AT+ADDMOD6=1**   **~-~->** Enable trigger
566 566  
567 567  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
568 568  
... ... @@ -710,6 +710,7 @@
710 710  
711 711  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
712 712  
712 +
713 713  === 3.4.1 Common Commands ===
714 714  
715 715  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0