Last modified by Mengting Qiu on 2025/06/04 18:42

From version 83.6
edited by Xiaoling
on 2022/06/29 17:24
Change comment: There is no comment for this version
To version 83.5
edited by Xiaoling
on 2022/06/29 17:24
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -179,6 +179,7 @@
179 179  * Firmware upgradable via program port
180 180  * Counting
181 181  
182 +
182 182  == 1.4  Applications ==
183 183  
184 184  * Smart Buildings & Home Automation
... ... @@ -188,6 +188,7 @@
188 188  * Smart Cities
189 189  * Smart Factory
190 190  
192 +
191 191  == 1.5 Hardware Variants ==
192 192  
193 193  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -201,6 +201,7 @@
201 201  * 1 x Counting Port
202 202  )))
203 203  
206 +
204 204  = 2. Power ON Device =
205 205  
206 206  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -274,12 +274,12 @@
274 274  
275 275  There are five working modes + one interrupt mode on LT for different type application:
276 276  
277 -* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
278 -* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO
279 -* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
280 -* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
281 -* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
282 -* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
280 +* **(% style="color:blue" %)MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
281 +* **(% style="color:blue" %)MOD2**(%%): Double DI Counting + DO + RO
282 +* **(% style="color:blue" %)MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
283 +* **(% style="color:blue" %)MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
284 +* **(% style="color:blue" %)MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
285 +* **(% style="color:blue" %)ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
283 283  
284 284  
285 285  
... ... @@ -321,8 +321,6 @@
321 321  * [1] RO1 relay channel is close and the RO1 LED is ON.
322 322  * [0] RO2 relay channel is open and RO2 LED is OFF;
323 323  
324 -
325 -
326 326  **LT22222-L:**
327 327  
328 328  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -338,8 +338,6 @@
338 338  ** DO1 is high in case there is load between DO1 and V+.
339 339  ** DO1 LED is off in both case
340 340  
341 -
342 -
343 343  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
344 344  
345 345