From version < 83.6 >
edited by Xiaoling
on 2022/06/29 17:24
To version < 83.10 >
edited by Xiaoling
on 2022/06/29 17:30
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -413,6 +413,8 @@
413 413  [[image:image-20220523181246-5.png]]
414 414  
415 415  (((
416 +
417 +
416 416  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
417 417  )))
418 418  
... ... @@ -426,6 +426,7 @@
426 426  (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
427 427  )))
428 428  
431 +
429 429  (((
430 430  **To use counting mode, please run:**
431 431  )))
... ... @@ -558,8 +558,8 @@
558 558  
559 559  For example, if user has configured below commands:
560 560  
561 -* **AT+MOD=1 ** **~-~->** The normal working mode
562 -* **AT+ADDMOD6=1**   **~-~->** Enable trigger
564 +* **AT+MOD=1 ** **~-~->**  The normal working mode
565 +* **AT+ADDMOD6=1**   **~-~->**  Enable trigger
563 563  
564 564  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
565 565  
... ... @@ -566,8 +566,10 @@
566 566  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
567 567  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
568 568  
572 +
569 569  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
570 570  
575 +
571 571  (% style="color:#4f81bd" %)**Trigger base on voltage**:
572 572  
573 573  Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH>
... ... @@ -707,6 +707,8 @@
707 707  
708 708  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
709 709  
715 +
716 +
710 710  === 3.4.1 Common Commands ===
711 711  
712 712  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0