Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,7 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 +**LT-22222-L LoRa IO Controller User Manual ** 4 4 5 5 6 6 **Table of Contents:** ... ... @@ -166,6 +166,7 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 170 + 169 169 170 170 ))) 171 171 ... ... @@ -179,6 +179,8 @@ 179 179 * Firmware upgradable via program port 180 180 * Counting 181 181 184 + 185 + 182 182 == 1.4 Applications == 183 183 184 184 * Smart Buildings & Home Automation ... ... @@ -188,6 +188,8 @@ 188 188 * Smart Cities 189 189 * Smart Factory 190 190 195 + 196 + 191 191 == 1.5 Hardware Variants == 192 192 193 193 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -201,6 +201,7 @@ 201 201 * 1 x Counting Port 202 202 ))) 203 203 210 + 204 204 = 2. Power ON Device = 205 205 206 206 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -218,11 +218,11 @@ 218 218 == 3.1 How it works? == 219 219 220 220 ((( 221 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%)will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network.(% style="color:green" %)**TX LED**(%%)will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second.228 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 222 222 ))) 223 223 224 224 ((( 225 -In case user can 't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.232 +In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 226 226 ))) 227 227 228 228 ... ... @@ -274,12 +274,12 @@ 274 274 275 275 There are five working modes + one interrupt mode on LT for different type application: 276 276 277 -* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO278 -* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO279 -* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO280 -* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO281 -* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO282 -* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5284 +* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 285 +* **MOD2**: Double DI Counting + DO + RO 286 +* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 287 +* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 288 +* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 289 +* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 283 283 284 284 285 285 ... ... @@ -321,8 +321,6 @@ 321 321 * [1] RO1 relay channel is close and the RO1 LED is ON. 322 322 * [0] RO2 relay channel is open and RO2 LED is OFF; 323 323 324 - 325 - 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -389,20 +389,24 @@ 389 389 390 390 ((( 391 391 **For LT22222-L:** 397 +))) 392 392 399 +(% class="box infomessage" %) 400 +((( 401 +((( 402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 393 393 394 - (% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger onlowlevel, valid signal is 100ms) **404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 395 395 396 - (% style="color:blue" %)**AT+TRIG1=1,100**(%%)**1port to trigger onhighlevel, valid signal is 100ms406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 397 397 398 - (% style="color:blue" %)**AT+TRIG2=0,100**(%%)**lowlevel, valid signal is 100ms) **408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 399 399 400 - (% style="color:blue" %)**AT+TRIG2=1,100**(%%)**setDI2port to trigger on high level, validsignalis 100ms)410 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 401 401 402 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 403 - 404 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 412 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 405 405 ))) 414 +))) 406 406 407 407 408 408 ... ... @@ -494,19 +494,22 @@ 494 494 495 495 496 496 **Plus below command for AVI1 Counting:** 506 +))) 497 497 508 +(% class="box infomessage" %) 509 +((( 510 +((( 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 498 498 499 -(% style="color:blue" %)**AT+ SETCNT=3,60**(%%)**(set AVICountto60)**513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 500 500 501 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** higher than VOLMAX (20000mV =20v), counter increase 1)**515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 502 502 503 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 504 - 505 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 506 506 ))) 519 +))) 507 507 508 508 509 - 510 510 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 511 511 512 512 ... ... @@ -707,6 +707,8 @@ 707 707 708 708 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 709 709 722 + 723 + 710 710 === 3.4.1 Common Commands === 711 711 712 712 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -721,19 +721,23 @@ 721 721 722 722 * (% style="color:#037691" %)**AT Command:** 723 723 738 +(% class="box infomessage" %) 739 +((( 724 724 **AT+TDC=N ** 741 +))) 725 725 726 - 727 727 **Example: **AT+TDC=30000. Means set interval to 30 seconds 728 728 729 729 730 730 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 731 731 748 +(% class="box infomessage" %) 749 +((( 732 732 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 751 +))) 733 733 734 734 735 735 736 - 737 737 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 738 738 739 739 Set work mode. ... ... @@ -740,29 +740,36 @@ 740 740 741 741 * (% style="color:#037691" %)**AT Command:** 742 742 761 +(% class="box infomessage" %) 762 +((( 743 743 **AT+MOD=N ** 764 +))) 744 744 745 - 746 746 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 747 747 748 748 749 749 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 750 750 751 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 771 +(% class="box infomessage" %) 772 +((( 773 +**0x0A aa ~/~/ Same as AT+MOD=aa** 774 +))) 752 752 753 753 754 754 755 - 756 756 ==== 3.4.2.3 Poll an uplink ==== 757 757 758 -* (% style="color:#037691" %) **AT Command:**780 +* (% style="color:#037691" %)AT Command: 759 759 760 760 There is no AT Command to poll uplink 761 761 762 762 763 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x08):**785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 764 764 765 -**0x08 FF **~/~/ Poll an uplink 787 +(% class="box infomessage" %) 788 +((( 789 +**0x08 FF ~/~/ Poll an uplink,** 790 +))) 766 766 767 767 **Example**: 0x08FF, ask device to send an Uplink 768 768 ... ... @@ -772,9 +772,12 @@ 772 772 773 773 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 774 774 775 -* (% style="color:#037691" %) **AT Command:**800 +* (% style="color:#037691" %)AT Command: 776 776 802 +(% class="box infomessage" %) 803 +((( 777 777 **AT+ADDMOD6=1 or 0** 805 +))) 778 778 779 779 1: Enable Trigger Mode 780 780 ... ... @@ -781,36 +781,43 @@ 781 781 0: Disable Trigger Mode 782 782 783 783 784 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x0A 06):**812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 785 785 786 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 814 +(% class="box infomessage" %) 815 +((( 816 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 817 +))) 787 787 788 788 789 789 790 - 791 791 ==== 3.4.2.5 Poll trigger settings ==== 792 792 793 793 Poll trigger settings, 794 794 795 -* (% style="color:#037691" %) **AT Command:**825 +* (% style="color:#037691" %)AT Command: 796 796 797 797 There is no AT Command for this feature. 798 798 799 799 800 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 801 801 802 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 832 +(% class="box infomessage" %) 833 +((( 834 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 835 +))) 803 803 804 804 805 805 806 - 807 807 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 808 808 809 809 Enable Disable DI1/DI2/DI2 as trigger, 810 810 811 -* (% style="color:#037691" %) **AT Command:**843 +* (% style="color:#037691" %)AT Command: 812 812 845 +(% class="box infomessage" %) 846 +((( 813 813 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 +))) 814 814 815 815 816 816 **Example:** ... ... @@ -817,20 +817,25 @@ 817 817 818 818 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 819 819 820 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 821 821 822 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 857 +(% class="box infomessage" %) 858 +((( 859 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 +))) 823 823 824 824 825 825 826 - 827 827 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 828 828 829 829 Set DI1 or DI3(for LT-33222-L) trigger. 830 830 831 -* (% style="color:#037691" %) **AT Command:**868 +* (% style="color:#037691" %)AT Command: 832 832 870 +(% class="box infomessage" %) 871 +((( 833 833 **AT+TRIG1=a,b** 873 +))) 834 834 835 835 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 836 836 ... ... @@ -842,18 +842,26 @@ 842 842 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 843 843 844 844 845 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 846 -* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 847 847 887 +(% class="box infomessage" %) 888 +((( 889 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 +))) 891 + 892 + 893 + 848 848 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 849 849 850 850 Set DI2 trigger. 851 851 852 -* (% style="color:#037691" %) **AT Command:**898 +* (% style="color:#037691" %)AT Command: 853 853 900 +(% class="box infomessage" %) 901 +((( 854 854 **AT+TRIG2=a,b** 903 +))) 855 855 856 - 857 857 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 858 858 859 859 b : delay timing. ... ... @@ -864,62 +864,74 @@ 864 864 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 865 865 866 866 867 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x09 02 ):**915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 868 868 869 -**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 917 +(% class="box infomessage" %) 918 +((( 919 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 920 +))) 870 870 871 871 872 872 873 - 874 874 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 875 875 876 876 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 877 877 878 -* (% style="color:#037691" %) **AT Command**928 +* (% style="color:#037691" %)AT Command: 879 879 880 -**AT+ACLIM** 930 +(% class="box infomessage" %) 931 +((( 932 +**AT+ACLIM. ** 933 +))) 881 881 882 882 883 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 01 )**936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 884 884 885 -**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 938 +(% class="box infomessage" %) 939 +((( 940 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 941 +))) 886 886 887 887 888 888 889 - 890 890 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 891 891 892 892 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 893 893 894 -* (% style="color:#037691" %) **AT Command**949 +* (% style="color:#037691" %)AT Command: 895 895 896 -**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 954 +))) 897 897 898 898 899 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 00 )**957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 900 900 901 -**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 959 +(% class="box infomessage" %) 960 +((( 961 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 962 +))) 902 902 903 903 904 904 905 - 906 906 ==== 3.4.2.11 Trigger – Set minimum interval ==== 907 907 908 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.968 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 909 909 910 -* (% style="color:#037691" %) **AT Command**970 +* (% style="color:#037691" %)AT Command: 911 911 912 -**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 972 +(% class="box infomessage" %) 973 +((( 974 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 975 +))) 913 913 914 914 915 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAC )**978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 916 916 917 -**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 918 - 980 +(% class="box infomessage" %) 919 919 ((( 920 - 921 - 922 -(% style="color:red" %)Note: ATDC setting must be more than 5min 982 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 923 923 ))) 924 924 925 925 ... ... @@ -926,15 +926,19 @@ 926 926 927 927 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 928 928 929 -* (% style="color:#037691" %) **AT Command**989 +* (% style="color:#037691" %)AT Command: 930 930 931 931 There is no AT Command to control Digital Output 932 932 933 933 934 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 935 -* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 936 936 996 +(% class="box infomessage" %) 937 937 ((( 998 +**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 999 +))) 1000 + 1001 +((( 938 938 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 939 939 ))) 940 940 ... ... @@ -954,19 +954,22 @@ 954 954 955 955 956 956 957 - 958 958 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 959 959 960 -* (% style="color:#037691" %) **AT Command**1023 +* (% style="color:#037691" %)AT Command: 961 961 962 962 There is no AT Command to control Digital Output 963 963 964 964 965 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA9)**1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 966 966 967 -**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1030 +(% class="box infomessage" %) 1031 +((( 1032 +((( 1033 +**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1034 +))) 1035 +))) 968 968 969 - 970 970 This is to control the digital output time of DO pin. Include four bytes: 971 971 972 972 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1020,19 +1020,20 @@ 1020 1020 1021 1021 1022 1022 1023 - 1024 1024 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1025 1025 1026 -* (% style="color:#037691" %) **AT Command:**1092 +* (% style="color:#037691" %)AT Command: 1027 1027 1028 1028 There is no AT Command to control Relay Output 1029 1029 1030 1030 1031 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x03):**1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1032 1032 1033 -**0x03 aa bb **~/~/ Set RO1/RO2 output 1099 +(% class="box infomessage" %) 1100 +((( 1101 +**0x03 aa bb ~/~/ Set RO1/RO2 output** 1102 +))) 1034 1034 1035 - 1036 1036 ((( 1037 1037 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1038 1038 ))) ... ... @@ -1049,19 +1049,20 @@ 1049 1049 1050 1050 1051 1051 1052 - 1053 1053 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1054 1054 1055 -* (% style="color:#037691" %) **AT Command:**1122 +* (% style="color:#037691" %)AT Command: 1056 1056 1057 1057 There is no AT Command to control Relay Output 1058 1058 1059 1059 1060 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x05):**1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05): 1061 1061 1062 -**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1129 +(% class="box infomessage" %) 1130 +((( 1131 +**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1132 +))) 1063 1063 1064 - 1065 1065 This is to control the relay output time of relay. Include four bytes: 1066 1066 1067 1067 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1103,7 +1103,6 @@ 1103 1103 1104 1104 1105 1105 1106 - 1107 1107 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1108 1108 1109 1109 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] ... ... @@ -1110,7 +1110,7 @@ 1110 1110 1111 1111 * (% style="color:#037691" %)**AT Command:** 1112 1112 1113 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1181 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1114 1114 1115 1115 1116 1116 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1119,12 +1119,11 @@ 1119 1119 1120 1120 1121 1121 1122 - 1123 1123 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1124 1124 1125 1125 * (% style="color:#037691" %)**AT Command:** 1126 1126 1127 -**AT+SETCNT=aa,(bb cc dd ee) ** 1194 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1128 1128 1129 1129 aa: 1: Set count1, 1130 1130 ... ... @@ -1141,7 +1141,6 @@ 1141 1141 1142 1142 1143 1143 1144 - 1145 1145 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1146 1146 1147 1147 Clear counting for counting mode ... ... @@ -1148,7 +1148,7 @@ 1148 1148 1149 1149 * (% style="color:#037691" %)**AT Command:** 1150 1150 1151 -**AT+CLRCOUNT ** ~/~/ clear all counting 1217 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1152 1152 1153 1153 1154 1154 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1157,7 +1157,6 @@ 1157 1157 1158 1158 1159 1159 1160 - 1161 1161 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1162 1162 1163 1163 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1176,7 +1176,6 @@ 1176 1176 ))) 1177 1177 1178 1178 1179 - 1180 1180 == 3.5 Integrate with Mydevice == 1181 1181 1182 1182 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1406,7 +1406,6 @@ 1406 1406 [[image:image-20220524100748-11.png]] 1407 1407 1408 1408 1409 - 1410 1410 = 4. Use AT Command = 1411 1411 1412 1412 == 4.1 Access AT Command == ... ... @@ -1609,6 +1609,8 @@ 1609 1609 1610 1610 ((( 1611 1611 AT+CFG: Print all settings 1675 + 1676 + 1612 1612 ))) 1613 1613 1614 1614 ... ... @@ -1654,6 +1654,8 @@ 1654 1654 1655 1655 ((( 1656 1656 (% style="background-color:#dcdcdc" %)ATZ 1722 + 1723 + 1657 1657 ))) 1658 1658 1659 1659 ... ... @@ -1860,8 +1860,6 @@ 1860 1860 == 5.5 Can i use point to point communication for LT-22222-L? == 1861 1861 1862 1862 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1863 - 1864 - 1865 1865 ))) 1866 1866 1867 1867 ((( ... ... @@ -1875,7 +1875,6 @@ 1875 1875 1876 1876 After restart, the status before power failure will be read from flash. 1877 1877 1878 - 1879 1879 = 6. Trouble Shooting = 1880 1880 ))) 1881 1881 ... ... @@ -1910,8 +1910,10 @@ 1910 1910 ))) 1911 1911 1912 1912 1977 + 1913 1913 = 7. Order Info = 1914 1914 1980 + 1915 1915 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1916 1916 1917 1917 ... ... @@ -1951,10 +1951,6 @@ 1951 1951 ))) 1952 1952 * ((( 1953 1953 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1954 - 1955 - 1956 - 1957 - 1958 1958 ))) 1959 1959 1960 1960 = 10. Reference =