From version < 83.5 >
edited by Xiaoling
on 2022/06/29 17:24
To version < 83.6 >
edited by Xiaoling
on 2022/06/29 17:24
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -179,7 +179,6 @@
179 179  * Firmware upgradable via program port
180 180  * Counting
181 181  
182 -
183 183  == 1.4  Applications ==
184 184  
185 185  * Smart Buildings & Home Automation
... ... @@ -189,7 +189,6 @@
189 189  * Smart Cities
190 190  * Smart Factory
191 191  
192 -
193 193  == 1.5 Hardware Variants ==
194 194  
195 195  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -203,7 +203,6 @@
203 203  * 1 x Counting Port
204 204  )))
205 205  
206 -
207 207  = 2. Power ON Device =
208 208  
209 209  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -277,12 +277,12 @@
277 277  
278 278  There are five working modes + one interrupt mode on LT for different type application:
279 279  
280 -* **(% style="color:blue" %)MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
281 -* **(% style="color:blue" %)MOD2**(%%): Double DI Counting + DO + RO
282 -* **(% style="color:blue" %)MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
283 -* **(% style="color:blue" %)MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
284 -* **(% style="color:blue" %)MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
285 -* **(% style="color:blue" %)ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
278 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO
279 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
280 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
281 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
282 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
286 286  
287 287  
288 288  
... ... @@ -324,6 +324,8 @@
324 324  * [1] RO1 relay channel is close and the RO1 LED is ON.
325 325  * [0] RO2 relay channel is open and RO2 LED is OFF;
326 326  
324 +
325 +
327 327  **LT22222-L:**
328 328  
329 329  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -339,6 +339,8 @@
339 339  ** DO1 is high in case there is load between DO1 and V+.
340 340  ** DO1 LED is off in both case
341 341  
341 +
342 +
342 342  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
343 343  
344 344  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0