Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,7 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 +**LT-22222-L LoRa IO Controller User Manual ** 4 4 5 5 6 6 **Table of Contents:** ... ... @@ -166,6 +166,7 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 170 + 169 169 170 170 ))) 171 171 ... ... @@ -179,7 +179,6 @@ 179 179 * Firmware upgradable via program port 180 180 * Counting 181 181 182 - 183 183 == 1.4 Applications == 184 184 185 185 * Smart Buildings & Home Automation ... ... @@ -189,7 +189,6 @@ 189 189 * Smart Cities 190 190 * Smart Factory 191 191 192 - 193 193 == 1.5 Hardware Variants == 194 194 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -204,6 +204,7 @@ 204 204 ))) 205 205 206 206 207 + 207 207 = 2. Power ON Device = 208 208 209 209 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -221,11 +221,11 @@ 221 221 == 3.1 How it works? == 222 222 223 223 ((( 224 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%)will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network.(% style="color:green" %)**TX LED**(%%)will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second.225 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 225 225 ))) 226 226 227 227 ((( 228 -In case user can 't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.229 +In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 229 229 ))) 230 230 231 231 ... ... @@ -277,15 +277,13 @@ 277 277 278 278 There are five working modes + one interrupt mode on LT for different type application: 279 279 280 -* ** (% style="color:blue" %)MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO281 -* ** (% style="color:blue" %)MOD2**(%%): Double DI Counting + DO + RO282 -* ** (% style="color:blue" %)MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO283 -* ** (% style="color:blue" %)MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO284 -* ** (% style="color:blue" %)MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO285 -* ** (% style="color:blue" %)ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5281 +* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 282 +* **MOD2**: Double DI Counting + DO + RO 283 +* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 284 +* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 285 +* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 +* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 286 286 287 - 288 - 289 289 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 290 290 291 291 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -565,6 +565,7 @@ 565 565 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 566 566 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 567 567 567 + 568 568 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 569 569 570 570 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -747,7 +747,7 @@ 747 747 748 748 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 749 749 750 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 750 +(% style="color:#037691" %)****(%%)**0x0A aa ** ~/~/ Same as AT+MOD=aa 751 751 752 752 753 753 ... ... @@ -771,9 +771,12 @@ 771 771 772 772 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 773 773 774 -* (% style="color:#037691" %) **AT Command:**774 +* (% style="color:#037691" %)AT Command: 775 775 776 +(% class="box infomessage" %) 777 +((( 776 776 **AT+ADDMOD6=1 or 0** 779 +))) 777 777 778 778 1: Enable Trigger Mode 779 779 ... ... @@ -780,34 +780,38 @@ 780 780 0: Disable Trigger Mode 781 781 782 782 783 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x0A 06):**786 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 784 784 785 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 788 +(% class="box infomessage" %) 789 +((( 790 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 791 +))) 786 786 787 787 788 788 789 - 790 790 ==== 3.4.2.5 Poll trigger settings ==== 791 791 792 792 Poll trigger settings, 793 793 794 -* (% style="color:#037691" %) **AT Command:**799 +* (% style="color:#037691" %)AT Command: 795 795 796 796 There is no AT Command for this feature. 797 797 798 798 799 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**804 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 800 800 801 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 806 +(% class="box infomessage" %) 807 +((( 808 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 809 +))) 802 802 803 803 804 804 805 - 806 806 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 807 807 808 808 Enable Disable DI1/DI2/DI2 as trigger, 809 809 810 -* (% style="color:#037691" %) **AT Command:**817 +* (% style="color:#037691" %)AT Command: 811 811 812 812 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 813 813 ... ... @@ -816,7 +816,7 @@ 816 816 817 817 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 818 818 819 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**826 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 820 820 821 821 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 822 822 ... ... @@ -827,7 +827,7 @@ 827 827 828 828 Set DI1 or DI3(for LT-33222-L) trigger. 829 829 830 -* (% style="color:#037691" %) **AT Command:**837 +* (% style="color:#037691" %)AT Command: 831 831 832 832 **AT+TRIG1=a,b** 833 833 ... ... @@ -844,6 +844,7 @@ 844 844 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 845 845 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 846 846 854 + 847 847 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 848 848 849 849 Set DI2 trigger. ... ... @@ -904,11 +904,11 @@ 904 904 905 905 ==== 3.4.2.11 Trigger – Set minimum interval ==== 906 906 907 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.915 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 908 908 909 909 * (% style="color:#037691" %)**AT Command** 910 910 911 -**AT+ATDC=5 **Device won't response the second trigger within 5 minute after the first trigger.919 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 912 912 913 913 914 914 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -915,14 +915,9 @@ 915 915 916 916 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 917 917 918 -((( 919 - 920 920 921 -(% style="color:red" %)Note: ATDC setting must be more than 5min 922 -))) 923 923 924 924 925 - 926 926 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 927 927 928 928 * (% style="color:#037691" %)**AT Command** ... ... @@ -1123,7 +1123,7 @@ 1123 1123 1124 1124 * (% style="color:#037691" %)**AT Command:** 1125 1125 1126 -**AT+SETCNT=aa,(bb cc dd ee) ** 1129 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1127 1127 1128 1128 aa: 1: Set count1, 1129 1129 ... ... @@ -1147,7 +1147,7 @@ 1147 1147 1148 1148 * (% style="color:#037691" %)**AT Command:** 1149 1149 1150 -**AT+CLRCOUNT ** ~/~/ clear all counting 1153 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1151 1151 1152 1152 1153 1153 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1405,7 +1405,6 @@ 1405 1405 [[image:image-20220524100748-11.png]] 1406 1406 1407 1407 1408 - 1409 1409 = 4. Use AT Command = 1410 1410 1411 1411 == 4.1 Access AT Command == ... ... @@ -1608,6 +1608,8 @@ 1608 1608 1609 1609 ((( 1610 1610 AT+CFG: Print all settings 1613 + 1614 + 1611 1611 ))) 1612 1612 1613 1613 ... ... @@ -1653,6 +1653,8 @@ 1653 1653 1654 1654 ((( 1655 1655 (% style="background-color:#dcdcdc" %)ATZ 1660 + 1661 + 1656 1656 ))) 1657 1657 1658 1658 ... ... @@ -1859,8 +1859,6 @@ 1859 1859 == 5.5 Can i use point to point communication for LT-22222-L? == 1860 1860 1861 1861 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1862 - 1863 - 1864 1864 ))) 1865 1865 1866 1866 ((( ... ... @@ -1874,7 +1874,6 @@ 1874 1874 1875 1875 After restart, the status before power failure will be read from flash. 1876 1876 1877 - 1878 1878 = 6. Trouble Shooting = 1879 1879 ))) 1880 1880 ... ... @@ -1909,8 +1909,10 @@ 1909 1909 ))) 1910 1910 1911 1911 1915 + 1912 1912 = 7. Order Info = 1913 1913 1918 + 1914 1914 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1915 1915 1916 1916 ... ... @@ -1950,10 +1950,6 @@ 1950 1950 ))) 1951 1951 * ((( 1952 1952 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1953 - 1954 - 1955 - 1956 - 1957 1957 ))) 1958 1958 1959 1959 = 10. Reference =