Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,7 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 +**LT-22222-L LoRa IO Controller User Manual ** 4 4 5 5 6 6 **Table of Contents:** ... ... @@ -166,6 +166,7 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 170 + 169 169 170 170 ))) 171 171 ... ... @@ -180,6 +180,7 @@ 180 180 * Counting 181 181 182 182 185 + 183 183 == 1.4 Applications == 184 184 185 185 * Smart Buildings & Home Automation ... ... @@ -190,6 +190,7 @@ 190 190 * Smart Factory 191 191 192 192 196 + 193 193 == 1.5 Hardware Variants == 194 194 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -221,11 +221,11 @@ 221 221 == 3.1 How it works? == 222 222 223 223 ((( 224 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%)will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network.(% style="color:green" %)**TX LED**(%%)will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second.228 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 225 225 ))) 226 226 227 227 ((( 228 -In case user can 't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.232 +In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 229 229 ))) 230 230 231 231 ... ... @@ -277,12 +277,12 @@ 277 277 278 278 There are five working modes + one interrupt mode on LT for different type application: 279 279 280 -* ** (% style="color:blue" %)MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO281 -* ** (% style="color:blue" %)MOD2**(%%): Double DI Counting + DO + RO282 -* ** (% style="color:blue" %)MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO283 -* ** (% style="color:blue" %)MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO284 -* ** (% style="color:blue" %)MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO285 -* ** (% style="color:blue" %)ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5284 +* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 285 +* **MOD2**: Double DI Counting + DO + RO 286 +* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 287 +* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 288 +* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 289 +* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 286 286 287 287 288 288 ... ... @@ -339,6 +339,8 @@ 339 339 ** DO1 is high in case there is load between DO1 and V+. 340 340 ** DO1 LED is off in both case 341 341 346 + 347 + 342 342 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 343 343 344 344 ... ... @@ -388,20 +388,24 @@ 388 388 389 389 ((( 390 390 **For LT22222-L:** 397 +))) 391 391 399 +(% class="box infomessage" %) 400 +((( 401 +((( 402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 392 392 393 - (% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger onlowlevel, valid signal is 100ms) **404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 394 394 395 - (% style="color:blue" %)**AT+TRIG1=1,100**(%%)**1port to trigger onhighlevel, valid signal is 100ms406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 396 396 397 - (% style="color:blue" %)**AT+TRIG2=0,100**(%%)**lowlevel, valid signal is 100ms) **408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 398 398 399 - (% style="color:blue" %)**AT+TRIG2=1,100**(%%)**setDI2port to trigger on high level, validsignalis 100ms)410 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 400 400 401 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 402 - 403 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 412 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 404 404 ))) 414 +))) 405 405 406 406 407 407 ... ... @@ -493,19 +493,22 @@ 493 493 494 494 495 495 **Plus below command for AVI1 Counting:** 506 +))) 496 496 508 +(% class="box infomessage" %) 509 +((( 510 +((( 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 497 497 498 -(% style="color:blue" %)**AT+ SETCNT=3,60**(%%)**(set AVICountto60)**513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 499 499 500 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** higher than VOLMAX (20000mV =20v), counter increase 1)**515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 501 501 502 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 503 - 504 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 505 505 ))) 519 +))) 506 506 507 507 508 - 509 509 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 510 510 511 511 ... ... @@ -706,6 +706,8 @@ 706 706 707 707 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 708 708 722 + 723 + 709 709 === 3.4.1 Common Commands === 710 710 711 711 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -720,19 +720,23 @@ 720 720 721 721 * (% style="color:#037691" %)**AT Command:** 722 722 738 +(% class="box infomessage" %) 739 +((( 723 723 **AT+TDC=N ** 741 +))) 724 724 725 - 726 726 **Example: **AT+TDC=30000. Means set interval to 30 seconds 727 727 728 728 729 729 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 730 730 748 +(% class="box infomessage" %) 749 +((( 731 731 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 751 +))) 732 732 733 733 734 734 735 - 736 736 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 737 737 738 738 Set work mode. ... ... @@ -739,29 +739,36 @@ 739 739 740 740 * (% style="color:#037691" %)**AT Command:** 741 741 761 +(% class="box infomessage" %) 762 +((( 742 742 **AT+MOD=N ** 764 +))) 743 743 744 - 745 745 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 746 746 747 747 748 748 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 749 749 750 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 771 +(% class="box infomessage" %) 772 +((( 773 +**0x0A aa ~/~/ Same as AT+MOD=aa** 774 +))) 751 751 752 752 753 753 754 - 755 755 ==== 3.4.2.3 Poll an uplink ==== 756 756 757 -* (% style="color:#037691" %) **AT Command:**780 +* (% style="color:#037691" %)AT Command: 758 758 759 759 There is no AT Command to poll uplink 760 760 761 761 762 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x08):**785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 763 763 764 -**0x08 FF **~/~/ Poll an uplink 787 +(% class="box infomessage" %) 788 +((( 789 +**0x08 FF ~/~/ Poll an uplink,** 790 +))) 765 765 766 766 **Example**: 0x08FF, ask device to send an Uplink 767 767 ... ... @@ -771,9 +771,12 @@ 771 771 772 772 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 773 773 774 -* (% style="color:#037691" %) **AT Command:**800 +* (% style="color:#037691" %)AT Command: 775 775 802 +(% class="box infomessage" %) 803 +((( 776 776 **AT+ADDMOD6=1 or 0** 805 +))) 777 777 778 778 1: Enable Trigger Mode 779 779 ... ... @@ -780,36 +780,43 @@ 780 780 0: Disable Trigger Mode 781 781 782 782 783 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x0A 06):**812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 784 784 785 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 814 +(% class="box infomessage" %) 815 +((( 816 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 817 +))) 786 786 787 787 788 788 789 - 790 790 ==== 3.4.2.5 Poll trigger settings ==== 791 791 792 792 Poll trigger settings, 793 793 794 -* (% style="color:#037691" %) **AT Command:**825 +* (% style="color:#037691" %)AT Command: 795 795 796 796 There is no AT Command for this feature. 797 797 798 798 799 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 800 800 801 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 832 +(% class="box infomessage" %) 833 +((( 834 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 835 +))) 802 802 803 803 804 804 805 - 806 806 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 807 807 808 808 Enable Disable DI1/DI2/DI2 as trigger, 809 809 810 -* (% style="color:#037691" %) **AT Command:**843 +* (% style="color:#037691" %)AT Command: 811 811 845 +(% class="box infomessage" %) 846 +((( 812 812 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 +))) 813 813 814 814 815 815 **Example:** ... ... @@ -816,20 +816,25 @@ 816 816 817 817 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 818 818 819 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 820 820 821 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 857 +(% class="box infomessage" %) 858 +((( 859 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 +))) 822 822 823 823 824 824 825 - 826 826 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 827 827 828 828 Set DI1 or DI3(for LT-33222-L) trigger. 829 829 830 -* (% style="color:#037691" %) **AT Command:**868 +* (% style="color:#037691" %)AT Command: 831 831 870 +(% class="box infomessage" %) 871 +((( 832 832 **AT+TRIG1=a,b** 873 +))) 833 833 834 834 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 835 835 ... ... @@ -841,18 +841,26 @@ 841 841 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 842 842 843 843 844 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 845 -* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 846 846 887 +(% class="box infomessage" %) 888 +((( 889 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 +))) 891 + 892 + 893 + 847 847 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 848 848 849 849 Set DI2 trigger. 850 850 851 -* (% style="color:#037691" %) **AT Command:**898 +* (% style="color:#037691" %)AT Command: 852 852 900 +(% class="box infomessage" %) 901 +((( 853 853 **AT+TRIG2=a,b** 903 +))) 854 854 855 - 856 856 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 857 857 858 858 b : delay timing. ... ... @@ -863,62 +863,74 @@ 863 863 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 864 864 865 865 866 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x09 02 ):**915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 867 867 868 -**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 917 +(% class="box infomessage" %) 918 +((( 919 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 920 +))) 869 869 870 870 871 871 872 - 873 873 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 874 874 875 875 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 876 876 877 -* (% style="color:#037691" %) **AT Command**928 +* (% style="color:#037691" %)AT Command: 878 878 879 -**AT+ACLIM** 930 +(% class="box infomessage" %) 931 +((( 932 +**AT+ACLIM. ** 933 +))) 880 880 881 881 882 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 01 )**936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 883 883 884 -**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 938 +(% class="box infomessage" %) 939 +((( 940 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 941 +))) 885 885 886 886 887 887 888 - 889 889 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 890 890 891 891 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 892 892 893 -* (% style="color:#037691" %) **AT Command**949 +* (% style="color:#037691" %)AT Command: 894 894 895 -**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 954 +))) 896 896 897 897 898 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 00 )**957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 899 899 900 -**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 959 +(% class="box infomessage" %) 960 +((( 961 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 962 +))) 901 901 902 902 903 903 904 - 905 905 ==== 3.4.2.11 Trigger – Set minimum interval ==== 906 906 907 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.968 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 908 908 909 -* (% style="color:#037691" %) **AT Command**970 +* (% style="color:#037691" %)AT Command: 910 910 911 -**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 972 +(% class="box infomessage" %) 973 +((( 974 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 975 +))) 912 912 913 913 914 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAC )**978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 915 915 916 -**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 917 - 980 +(% class="box infomessage" %) 918 918 ((( 919 - 920 - 921 -(% style="color:red" %)Note: ATDC setting must be more than 5min 982 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 922 922 ))) 923 923 924 924 ... ... @@ -925,15 +925,19 @@ 925 925 926 926 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 927 927 928 -* (% style="color:#037691" %) **AT Command**989 +* (% style="color:#037691" %)AT Command: 929 929 930 930 There is no AT Command to control Digital Output 931 931 932 932 933 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 934 -* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 935 935 996 +(% class="box infomessage" %) 936 936 ((( 998 +**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 999 +))) 1000 + 1001 +((( 937 937 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 938 938 ))) 939 939 ... ... @@ -953,19 +953,22 @@ 953 953 954 954 955 955 956 - 957 957 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 958 958 959 -* (% style="color:#037691" %) **AT Command**1023 +* (% style="color:#037691" %)AT Command: 960 960 961 961 There is no AT Command to control Digital Output 962 962 963 963 964 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA9)**1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 965 965 966 -**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1030 +(% class="box infomessage" %) 1031 +((( 1032 +((( 1033 +**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1034 +))) 1035 +))) 967 967 968 - 969 969 This is to control the digital output time of DO pin. Include four bytes: 970 970 971 971 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1019,19 +1019,20 @@ 1019 1019 1020 1020 1021 1021 1022 - 1023 1023 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1024 1024 1025 -* (% style="color:#037691" %) **AT Command:**1092 +* (% style="color:#037691" %)AT Command: 1026 1026 1027 1027 There is no AT Command to control Relay Output 1028 1028 1029 1029 1030 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x03):**1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1031 1031 1032 -**0x03 aa bb **~/~/ Set RO1/RO2 output 1099 +(% class="box infomessage" %) 1100 +((( 1101 +**0x03 aa bb ~/~/ Set RO1/RO2 output** 1102 +))) 1033 1033 1034 - 1035 1035 ((( 1036 1036 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1037 1037 ))) ... ... @@ -1048,19 +1048,20 @@ 1048 1048 1049 1049 1050 1050 1051 - 1052 1052 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1053 1053 1054 -* (% style="color:#037691" %) **AT Command:**1122 +* (% style="color:#037691" %)AT Command: 1055 1055 1056 1056 There is no AT Command to control Relay Output 1057 1057 1058 1058 1059 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x05):**1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05): 1060 1060 1061 -**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1129 +(% class="box infomessage" %) 1130 +((( 1131 +**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1132 +))) 1062 1062 1063 - 1064 1064 This is to control the relay output time of relay. Include four bytes: 1065 1065 1066 1066 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1102,7 +1102,6 @@ 1102 1102 1103 1103 1104 1104 1105 - 1106 1106 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1107 1107 1108 1108 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] ... ... @@ -1109,7 +1109,7 @@ 1109 1109 1110 1110 * (% style="color:#037691" %)**AT Command:** 1111 1111 1112 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1181 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1113 1113 1114 1114 1115 1115 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1118,12 +1118,11 @@ 1118 1118 1119 1119 1120 1120 1121 - 1122 1122 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1123 1123 1124 1124 * (% style="color:#037691" %)**AT Command:** 1125 1125 1126 -**AT+SETCNT=aa,(bb cc dd ee) ** 1194 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1127 1127 1128 1128 aa: 1: Set count1, 1129 1129 ... ... @@ -1140,7 +1140,6 @@ 1140 1140 1141 1141 1142 1142 1143 - 1144 1144 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1145 1145 1146 1146 Clear counting for counting mode ... ... @@ -1147,7 +1147,7 @@ 1147 1147 1148 1148 * (% style="color:#037691" %)**AT Command:** 1149 1149 1150 -**AT+CLRCOUNT ** ~/~/ clear all counting 1217 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1151 1151 1152 1152 1153 1153 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1156,7 +1156,6 @@ 1156 1156 1157 1157 1158 1158 1159 - 1160 1160 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1161 1161 1162 1162 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1175,7 +1175,6 @@ 1175 1175 ))) 1176 1176 1177 1177 1178 - 1179 1179 == 3.5 Integrate with Mydevice == 1180 1180 1181 1181 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1405,7 +1405,6 @@ 1405 1405 [[image:image-20220524100748-11.png]] 1406 1406 1407 1407 1408 - 1409 1409 = 4. Use AT Command = 1410 1410 1411 1411 == 4.1 Access AT Command == ... ... @@ -1608,6 +1608,8 @@ 1608 1608 1609 1609 ((( 1610 1610 AT+CFG: Print all settings 1675 + 1676 + 1611 1611 ))) 1612 1612 1613 1613 ... ... @@ -1653,6 +1653,8 @@ 1653 1653 1654 1654 ((( 1655 1655 (% style="background-color:#dcdcdc" %)ATZ 1722 + 1723 + 1656 1656 ))) 1657 1657 1658 1658 ... ... @@ -1859,8 +1859,6 @@ 1859 1859 == 5.5 Can i use point to point communication for LT-22222-L? == 1860 1860 1861 1861 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1862 - 1863 - 1864 1864 ))) 1865 1865 1866 1866 ((( ... ... @@ -1874,7 +1874,6 @@ 1874 1874 1875 1875 After restart, the status before power failure will be read from flash. 1876 1876 1877 - 1878 1878 = 6. Trouble Shooting = 1879 1879 ))) 1880 1880 ... ... @@ -1909,8 +1909,10 @@ 1909 1909 ))) 1910 1910 1911 1911 1977 + 1912 1912 = 7. Order Info = 1913 1913 1980 + 1914 1914 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1915 1915 1916 1916 ... ... @@ -1950,10 +1950,6 @@ 1950 1950 ))) 1951 1951 * ((( 1952 1952 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1953 - 1954 - 1955 - 1956 - 1957 1957 ))) 1958 1958 1959 1959 = 10. Reference =