Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -179,8 +179,6 @@ 179 179 * Firmware upgradable via program port 180 180 * Counting 181 181 182 - 183 - 184 184 == 1.4 Applications == 185 185 186 186 * Smart Buildings & Home Automation ... ... @@ -190,8 +190,6 @@ 190 190 * Smart Cities 191 191 * Smart Factory 192 192 193 - 194 - 195 195 == 1.5 Hardware Variants == 196 196 197 197 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -205,8 +205,6 @@ 205 205 * 1 x Counting Port 206 206 ))) 207 207 208 - 209 - 210 210 = 2. Power ON Device = 211 211 212 212 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -224,11 +224,11 @@ 224 224 == 3.1 How it works? == 225 225 226 226 ((( 227 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **(% style="color:green" %)TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network.**(% style="color:green" %)TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the**RX LED**will be on for 1 second.221 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 228 228 ))) 229 229 230 230 ((( 231 -In case user can ’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.225 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 232 232 ))) 233 233 234 234 ... ... @@ -280,14 +280,13 @@ 280 280 281 281 There are five working modes + one interrupt mode on LT for different type application: 282 282 283 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 284 -* **MOD2**: Double DI Counting + DO + RO 285 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 286 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 287 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 288 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 277 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 278 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 279 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 280 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 281 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 282 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 289 289 290 - 291 291 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 292 292 293 293 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -341,7 +341,6 @@ 341 341 ** DO1 is high in case there is load between DO1 and V+. 342 342 ** DO1 LED is off in both case 343 343 344 - 345 345 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 346 346 347 347 ... ... @@ -415,6 +415,8 @@ 415 415 [[image:image-20220523181246-5.png]] 416 416 417 417 ((( 410 + 411 + 418 418 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 419 419 ))) 420 420 ... ... @@ -428,6 +428,7 @@ 428 428 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 429 429 ))) 430 430 425 + 431 431 ((( 432 432 **To use counting mode, please run:** 433 433 ))) ... ... @@ -560,8 +560,8 @@ 560 560 561 561 For example, if user has configured below commands: 562 562 563 -* **AT+MOD=1 ** **~-~->** The normal working mode 564 -* **AT+ADDMOD6=1** **~-~->** Enable trigger 558 +* **AT+MOD=1 ** **~-~->** The normal working mode 559 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 565 565 566 566 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 567 567 ... ... @@ -570,6 +570,7 @@ 570 570 571 571 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 572 572 568 + 573 573 (% style="color:#4f81bd" %)**Trigger base on voltage**: 574 574 575 575 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -709,7 +709,6 @@ 709 709 710 710 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 711 711 712 - 713 713 === 3.4.1 Common Commands === 714 714 715 715 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -718,6 +718,7 @@ 718 718 719 719 === 3.4.2 Sensor related commands === 720 720 716 + 721 721 ==== 3.4.2.1 Set Transmit Interval ==== 722 722 723 723 Set device uplink interval. ... ... @@ -771,6 +771,7 @@ 771 771 772 772 773 773 770 + 774 774 ==== 3.4.2.4 Enable Trigger Mode ==== 775 775 776 776 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ... ... @@ -927,6 +927,7 @@ 927 927 928 928 929 929 927 + 930 930 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 931 931 932 932 * (% style="color:#037691" %)**AT Command** ... ... @@ -1769,7 +1769,7 @@ 1769 1769 1770 1770 1771 1771 (% style="color:blue" %)**For LT-22222-L**(%%): 1772 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1770 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1773 1773 ))) 1774 1774 1775 1775 [[image:image-20220524103407-12.png]] ... ... @@ -1884,7 +1884,7 @@ 1884 1884 1885 1885 ((( 1886 1886 ((( 1887 -== 6.1 Downlink doesn ’t work, how to solve it? ==1885 +== 6.1 Downlink doesn't work, how to solve it? == 1888 1888 ))) 1889 1889 ))) 1890 1890 ... ... @@ -1905,7 +1905,7 @@ 1905 1905 ((( 1906 1906 1907 1907 1908 -== 6.3 Why I can ’t join TTN in US915 /AU915 bands? ==1906 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 1909 1909 ))) 1910 1910 1911 1911 ((( ... ... @@ -1915,21 +1915,25 @@ 1915 1915 1916 1916 = 7. Order Info = 1917 1917 1916 + 1918 1918 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1919 1919 1920 - 1921 1921 (% style="color:#4f81bd" %)**XXX:** 1922 1922 1923 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331924 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681925 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201926 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701927 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231928 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151929 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151930 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651931 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7791921 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 1922 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 1923 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 1924 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 1925 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 1926 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 1927 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 1928 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 1929 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1932 1932 1931 + 1932 + 1933 + 1934 + 1933 1933 = 8. Packing Info = 1934 1934 1935 1935 ... ... @@ -1947,6 +1947,10 @@ 1947 1947 * Package Size / pcs : 14.5 x 8 x 5 cm 1948 1948 * Weight / pcs : 170g 1949 1949 1952 + 1953 + 1954 + 1955 + 1950 1950 = 9. Support = 1951 1951 1952 1952 * ((( ... ... @@ -1954,11 +1954,10 @@ 1954 1954 ))) 1955 1955 * ((( 1956 1956 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1963 +))) 1957 1957 1958 1958 1959 1959 1960 - 1961 -))) 1962 1962 1963 1963 = 10. Reference = 1964 1964