Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,7 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 +**LT-22222-L LoRa IO Controller User Manual ** 4 4 5 5 6 6 **Table of Contents:** ... ... @@ -166,6 +166,7 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 170 + 169 169 170 170 ))) 171 171 ... ... @@ -206,7 +206,6 @@ 206 206 ))) 207 207 208 208 209 - 210 210 = 2. Power ON Device = 211 211 212 212 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -224,7 +224,7 @@ 224 224 == 3.1 How it works? == 225 225 226 226 ((( 227 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on ** (% style="color:green" %)TX LED**(%%)will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **(% style="color:green" %)TX LED**(%%)will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second.228 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 228 228 ))) 229 229 230 230 ((( ... ... @@ -288,6 +288,7 @@ 288 288 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 289 289 290 290 292 + 291 291 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 292 292 293 293 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -342,6 +342,7 @@ 342 342 ** DO1 LED is off in both case 343 343 344 344 347 + 345 345 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 346 346 347 347 ... ... @@ -391,20 +391,24 @@ 391 391 392 392 ((( 393 393 **For LT22222-L:** 397 +))) 394 394 399 +(% class="box infomessage" %) 400 +((( 401 +((( 402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 395 395 396 - (% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger onlowlevel, valid signal is 100ms) **404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 397 397 398 - (% style="color:blue" %)**AT+TRIG1=1,100**(%%)**1port to trigger onhighlevel, valid signal is 100ms406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 399 399 400 - (% style="color:blue" %)**AT+TRIG2=0,100**(%%)**lowlevel, valid signal is 100ms) **408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 401 401 402 - (% style="color:blue" %)**AT+TRIG2=1,100**(%%)**setDI2port to trigger on high level, validsignalis 100ms)410 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 403 403 404 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 405 - 406 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 412 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 407 407 ))) 414 +))) 408 408 409 409 410 410 ... ... @@ -496,19 +496,22 @@ 496 496 497 497 498 498 **Plus below command for AVI1 Counting:** 506 +))) 499 499 508 +(% class="box infomessage" %) 509 +((( 510 +((( 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 500 500 501 -(% style="color:blue" %)**AT+ SETCNT=3,60**(%%)**(set AVICountto60)**513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 502 502 503 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** higher than VOLMAX (20000mV =20v), counter increase 1)**515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 504 504 505 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 506 - 507 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 508 508 ))) 519 +))) 509 509 510 510 511 - 512 512 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 513 513 514 514 ... ... @@ -710,6 +710,7 @@ 710 710 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 711 711 712 712 723 + 713 713 === 3.4.1 Common Commands === 714 714 715 715 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -724,19 +724,23 @@ 724 724 725 725 * (% style="color:#037691" %)**AT Command:** 726 726 738 +(% class="box infomessage" %) 739 +((( 727 727 **AT+TDC=N ** 741 +))) 728 728 729 - 730 730 **Example: **AT+TDC=30000. Means set interval to 30 seconds 731 731 732 732 733 733 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 734 734 748 +(% class="box infomessage" %) 749 +((( 735 735 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 751 +))) 736 736 737 737 738 738 739 - 740 740 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 741 741 742 742 Set work mode. ... ... @@ -743,29 +743,36 @@ 743 743 744 744 * (% style="color:#037691" %)**AT Command:** 745 745 761 +(% class="box infomessage" %) 762 +((( 746 746 **AT+MOD=N ** 764 +))) 747 747 748 - 749 749 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 750 750 751 751 752 752 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 753 753 754 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 771 +(% class="box infomessage" %) 772 +((( 773 +**0x0A aa ~/~/ Same as AT+MOD=aa** 774 +))) 755 755 756 756 757 757 758 - 759 759 ==== 3.4.2.3 Poll an uplink ==== 760 760 761 -* (% style="color:#037691" %) **AT Command:**780 +* (% style="color:#037691" %)AT Command: 762 762 763 763 There is no AT Command to poll uplink 764 764 765 765 766 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x08):**785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 767 767 768 -**0x08 FF **~/~/ Poll an uplink 787 +(% class="box infomessage" %) 788 +((( 789 +**0x08 FF ~/~/ Poll an uplink,** 790 +))) 769 769 770 770 **Example**: 0x08FF, ask device to send an Uplink 771 771 ... ... @@ -775,9 +775,12 @@ 775 775 776 776 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 777 777 778 -* (% style="color:#037691" %) **AT Command:**800 +* (% style="color:#037691" %)AT Command: 779 779 802 +(% class="box infomessage" %) 803 +((( 780 780 **AT+ADDMOD6=1 or 0** 805 +))) 781 781 782 782 1: Enable Trigger Mode 783 783 ... ... @@ -784,36 +784,43 @@ 784 784 0: Disable Trigger Mode 785 785 786 786 787 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x0A 06):**812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 788 788 789 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 814 +(% class="box infomessage" %) 815 +((( 816 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 817 +))) 790 790 791 791 792 792 793 - 794 794 ==== 3.4.2.5 Poll trigger settings ==== 795 795 796 796 Poll trigger settings, 797 797 798 -* (% style="color:#037691" %) **AT Command:**825 +* (% style="color:#037691" %)AT Command: 799 799 800 800 There is no AT Command for this feature. 801 801 802 802 803 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 804 804 805 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 832 +(% class="box infomessage" %) 833 +((( 834 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 835 +))) 806 806 807 807 808 808 809 - 810 810 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 811 811 812 812 Enable Disable DI1/DI2/DI2 as trigger, 813 813 814 -* (% style="color:#037691" %) **AT Command:**843 +* (% style="color:#037691" %)AT Command: 815 815 845 +(% class="box infomessage" %) 846 +((( 816 816 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 +))) 817 817 818 818 819 819 **Example:** ... ... @@ -820,18 +820,20 @@ 820 820 821 821 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 822 822 823 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 824 824 825 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 857 +(% class="box infomessage" %) 858 +((( 859 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 +))) 826 826 827 827 828 828 829 - 830 830 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 831 831 832 832 Set DI1 or DI3(for LT-33222-L) trigger. 833 833 834 -* (% style="color:#037691" %) **AT Command:**868 +* (% style="color:#037691" %)AT Command: 835 835 836 836 **AT+TRIG1=a,b** 837 837 ... ... @@ -846,8 +846,11 @@ 846 846 847 847 848 848 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 849 -* **0x09 01 aa bb cc 883 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 850 850 885 + 886 + 887 + 851 851 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 852 852 853 853 Set DI2 trigger. ... ... @@ -869,7 +869,7 @@ 869 869 870 870 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 871 871 872 -**0x09 02 aa bb cc 909 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 873 873 874 874 875 875 ... ... @@ -885,7 +885,7 @@ 885 885 886 886 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 887 887 888 -**0x AA 01 aa bb cc dd ee ff gg hh 925 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 889 889 890 890 891 891 ... ... @@ -901,7 +901,7 @@ 901 901 902 902 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 903 903 904 -**0x AA 00 aa bb cc dd ee ff gg hh 941 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 905 905 906 906 907 907 ... ... @@ -908,25 +908,20 @@ 908 908 909 909 ==== 3.4.2.11 Trigger – Set minimum interval ==== 910 910 911 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.948 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 912 912 913 913 * (% style="color:#037691" %)**AT Command** 914 914 915 -**AT+ATDC=5 **Device won't response the second trigger within 5 minute after the first trigger.952 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 916 916 917 917 918 918 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 919 919 920 -**0x AC aa bb 957 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 921 921 922 -((( 923 - 924 924 925 -(% style="color:red" %)Note: ATDC setting must be more than 5min 926 -))) 927 927 928 928 929 - 930 930 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 931 931 932 932 * (% style="color:#037691" %)**AT Command** ... ... @@ -937,6 +937,7 @@ 937 937 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 938 938 * **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 939 939 972 + 940 940 ((( 941 941 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 942 942 ))) ... ... @@ -1113,7 +1113,7 @@ 1113 1113 1114 1114 * (% style="color:#037691" %)**AT Command:** 1115 1115 1116 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1149 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1117 1117 1118 1118 1119 1119 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1127,7 +1127,7 @@ 1127 1127 1128 1128 * (% style="color:#037691" %)**AT Command:** 1129 1129 1130 -**AT+SETCNT=aa,(bb cc dd ee) ** 1163 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1131 1131 1132 1132 aa: 1: Set count1, 1133 1133 ... ... @@ -1151,7 +1151,7 @@ 1151 1151 1152 1152 * (% style="color:#037691" %)**AT Command:** 1153 1153 1154 -**AT+CLRCOUNT ** ~/~/ clear all counting 1187 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1155 1155 1156 1156 1157 1157 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1409,7 +1409,6 @@ 1409 1409 [[image:image-20220524100748-11.png]] 1410 1410 1411 1411 1412 - 1413 1413 = 4. Use AT Command = 1414 1414 1415 1415 == 4.1 Access AT Command == ... ... @@ -1612,6 +1612,8 @@ 1612 1612 1613 1613 ((( 1614 1614 AT+CFG: Print all settings 1647 + 1648 + 1615 1615 ))) 1616 1616 1617 1617 ... ... @@ -1657,6 +1657,8 @@ 1657 1657 1658 1658 ((( 1659 1659 (% style="background-color:#dcdcdc" %)ATZ 1694 + 1695 + 1660 1660 ))) 1661 1661 1662 1662 ... ... @@ -1863,8 +1863,6 @@ 1863 1863 == 5.5 Can i use point to point communication for LT-22222-L? == 1864 1864 1865 1865 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1866 - 1867 - 1868 1868 ))) 1869 1869 1870 1870 ((( ... ... @@ -1878,7 +1878,6 @@ 1878 1878 1879 1879 After restart, the status before power failure will be read from flash. 1880 1880 1881 - 1882 1882 = 6. Trouble Shooting = 1883 1883 ))) 1884 1884 ... ... @@ -1913,8 +1913,10 @@ 1913 1913 ))) 1914 1914 1915 1915 1949 + 1916 1916 = 7. Order Info = 1917 1917 1952 + 1918 1918 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1919 1919 1920 1920 ... ... @@ -1954,10 +1954,6 @@ 1954 1954 ))) 1955 1955 * ((( 1956 1956 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1957 - 1958 - 1959 - 1960 - 1961 1961 ))) 1962 1962 1963 1963 = 10. Reference =