From version < 83.3 >
edited by Xiaoling
on 2022/06/29 17:17
To version < 83.5 >
edited by Xiaoling
on 2022/06/29 17:24
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -180,7 +180,6 @@
180 180  * Counting
181 181  
182 182  
183 -
184 184  == 1.4  Applications ==
185 185  
186 186  * Smart Buildings & Home Automation
... ... @@ -191,7 +191,6 @@
191 191  * Smart Factory
192 192  
193 193  
194 -
195 195  == 1.5 Hardware Variants ==
196 196  
197 197  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -206,7 +206,6 @@
206 206  )))
207 207  
208 208  
209 -
210 210  = 2. Power ON Device =
211 211  
212 212  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -224,11 +224,11 @@
224 224  == 3.1 How it works? ==
225 225  
226 226  (((
227 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 
224 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 
228 228  )))
229 229  
230 230  (((
231 -In case user cant set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
228 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
232 232  )))
233 233  
234 234  
... ... @@ -280,14 +280,15 @@
280 280  
281 281  There are five working modes + one interrupt mode on LT for different type application:
282 282  
283 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO
284 -* **MOD2**: Double DI Counting + DO + RO
285 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO
286 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO
287 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
288 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
280 +* **(% style="color:blue" %)MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
281 +* **(% style="color:blue" %)MOD2**(%%): Double DI Counting + DO + RO
282 +* **(% style="color:blue" %)MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
283 +* **(% style="color:blue" %)MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
284 +* **(% style="color:blue" %)MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
285 +* **(% style="color:blue" %)ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
289 289  
290 290  
288 +
291 291  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
292 292  
293 293  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -341,7 +341,6 @@
341 341  ** DO1 is high in case there is load between DO1 and V+.
342 342  ** DO1 LED is off in both case
343 343  
344 -
345 345  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
346 346  
347 347  
... ... @@ -709,7 +709,6 @@
709 709  
710 710  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
711 711  
712 -
713 713  === 3.4.1 Common Commands ===
714 714  
715 715  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0