Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -41,6 +41,8 @@ 41 41 42 42 ((( 43 43 2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless. 44 + 45 + 44 44 ))) 45 45 46 46 ((( ... ... @@ -166,11 +166,13 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 171 + 169 169 170 170 ))) 171 171 172 172 == 1.3 Features == 173 173 177 + 174 174 * LoRaWAN Class A & Class C protocol 175 175 * Optional Customized LoRa Protocol 176 176 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 ... ... @@ -179,8 +179,11 @@ 179 179 * Firmware upgradable via program port 180 180 * Counting 181 181 186 + 187 + 182 182 == 1.4 Applications == 183 183 190 + 184 184 * Smart Buildings & Home Automation 185 185 * Logistics and Supply Chain Management 186 186 * Smart Metering ... ... @@ -188,8 +188,11 @@ 188 188 * Smart Cities 189 189 * Smart Factory 190 190 198 + 199 + 191 191 == 1.5 Hardware Variants == 192 192 202 + 193 193 (% border="1" style="background-color:#f7faff; width:500px" %) 194 194 |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 195 195 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( ... ... @@ -201,8 +201,10 @@ 201 201 * 1 x Counting Port 202 202 ))) 203 203 214 + 204 204 = 2. Power ON Device = 205 205 217 + 206 206 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 207 207 208 208 ((( ... ... @@ -217,6 +217,7 @@ 217 217 218 218 == 3.1 How it works? == 219 219 232 + 220 220 ((( 221 221 The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 222 222 ))) ... ... @@ -226,10 +226,14 @@ 226 226 ))) 227 227 228 228 242 + 229 229 == 3.2 Example to join LoRaWAN network == 230 230 245 + 231 231 ((( 232 232 This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 248 + 249 + 233 233 ))) 234 234 235 235 [[image:image-20220523172350-1.png||height="266" width="864"]] ... ... @@ -237,6 +237,8 @@ 237 237 238 238 ((( 239 239 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 257 + 258 + 240 240 ))) 241 241 242 242 ((( ... ... @@ -262,6 +262,7 @@ 262 262 [[image:1653298023685-319.png]] 263 263 264 264 284 + 265 265 ((( 266 266 (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 267 267 ))) ... ... @@ -272,6 +272,7 @@ 272 272 273 273 == 3.3 Uplink Payload == 274 274 295 + 275 275 There are five working modes + one interrupt mode on LT for different type application: 276 276 277 277 * (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO ... ... @@ -282,8 +282,10 @@ 282 282 * (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 283 283 284 284 306 + 285 285 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 286 286 309 + 287 287 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 288 288 289 289 [[image:image-20220523174024-3.png]] ... ... @@ -320,7 +320,6 @@ 320 320 * [1] RO1 relay channel is close and the RO1 LED is ON. 321 321 * [0] RO2 relay channel is open and RO2 LED is OFF; 322 322 323 - 324 324 **LT22222-L:** 325 325 326 326 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -337,6 +337,7 @@ 337 337 ** DO1 LED is off in both case 338 338 339 339 362 + 340 340 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 341 341 342 342 ... ... @@ -405,6 +405,7 @@ 405 405 406 406 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 407 407 431 + 408 408 **LT22222-L**: This mode the DI1 is used as a counting pin. 409 409 410 410 [[image:image-20220523181246-5.png]] ... ... @@ -690,14 +690,14 @@ 690 690 ((( 691 691 692 692 693 -**Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 694 - 695 - 717 +**Decoder for TTN/loraserver/ChirpStack**: [[https:~~/~~/www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0>>https://www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0]] 696 696 ))) 697 697 698 698 721 + 699 699 == 3.4 Configure LT via AT or Downlink == 700 700 724 + 701 701 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 702 702 703 703 ((( ... ... @@ -709,8 +709,11 @@ 709 709 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 710 710 711 711 736 + 737 + 712 712 === 3.4.1 Common Commands === 713 713 740 + 714 714 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 715 715 716 716 ... ... @@ -720,6 +720,7 @@ 720 720 721 721 ==== 3.4.2.1 Set Transmit Interval ==== 722 722 750 + 723 723 Set device uplink interval. 724 724 725 725 * (% style="color:#037691" %)**AT Command:** ... ... @@ -739,6 +739,7 @@ 739 739 740 740 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 741 741 770 + 742 742 Set work mode. 743 743 744 744 * (% style="color:#037691" %)**AT Command:** ... ... @@ -758,6 +758,7 @@ 758 758 759 759 ==== 3.4.2.3 Poll an uplink ==== 760 760 790 + 761 761 * (% style="color:#037691" %)**AT Command:** 762 762 763 763 There is no AT Command to poll uplink ... ... @@ -774,6 +774,7 @@ 774 774 775 775 ==== 3.4.2.4 Enable Trigger Mode ==== 776 776 807 + 777 777 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 778 778 779 779 * (% style="color:#037691" %)**AT Command:** ... ... @@ -794,6 +794,7 @@ 794 794 795 795 ==== 3.4.2.5 Poll trigger settings ==== 796 796 828 + 797 797 Poll trigger settings, 798 798 799 799 * (% style="color:#037691" %)**AT Command:** ... ... @@ -810,6 +810,7 @@ 810 810 811 811 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 812 812 845 + 813 813 Enable Disable DI1/DI2/DI2 as trigger, 814 814 815 815 * (% style="color:#037691" %)**AT Command:** ... ... @@ -830,6 +830,7 @@ 830 830 831 831 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 832 832 866 + 833 833 Set DI1 or DI3(for LT-33222-L) trigger. 834 834 835 835 * (% style="color:#037691" %)**AT Command:** ... ... @@ -849,8 +849,11 @@ 849 849 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 850 850 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 851 851 886 + 887 + 852 852 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 853 853 890 + 854 854 Set DI2 trigger. 855 855 856 856 * (% style="color:#037691" %)**AT Command:** ... ... @@ -877,6 +877,7 @@ 877 877 878 878 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 879 879 917 + 880 880 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 881 881 882 882 * (% style="color:#037691" %)**AT Command** ... ... @@ -893,6 +893,7 @@ 893 893 894 894 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 895 895 934 + 896 896 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 897 897 898 898 * (% style="color:#037691" %)**AT Command** ... ... @@ -909,6 +909,7 @@ 909 909 910 910 ==== 3.4.2.11 Trigger – Set minimum interval ==== 911 911 951 + 912 912 Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 913 913 914 914 * (% style="color:#037691" %)**AT Command** ... ... @@ -931,6 +931,7 @@ 931 931 932 932 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 933 933 974 + 934 934 * (% style="color:#037691" %)**AT Command** 935 935 936 936 There is no AT Command to control Digital Output ... ... @@ -962,6 +962,7 @@ 962 962 963 963 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 964 964 1006 + 965 965 * (% style="color:#037691" %)**AT Command** 966 966 967 967 There is no AT Command to control Digital Output ... ... @@ -1028,6 +1028,7 @@ 1028 1028 1029 1029 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1030 1030 1073 + 1031 1031 * (% style="color:#037691" %)**AT Command:** 1032 1032 1033 1033 There is no AT Command to control Relay Output ... ... @@ -1057,6 +1057,7 @@ 1057 1057 1058 1058 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1059 1059 1103 + 1060 1060 * (% style="color:#037691" %)**AT Command:** 1061 1061 1062 1062 There is no AT Command to control Relay Output ... ... @@ -1080,7 +1080,7 @@ 1080 1080 1081 1081 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1082 1082 1083 -[[image:image-20220 524093831-10.png]]1127 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1084 1084 1085 1085 1086 1086 (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms ... ... @@ -1090,21 +1090,21 @@ 1090 1090 1091 1091 **Example payload:** 1092 1092 1093 -**~1. 05 01 11 07 D 0**1137 +**~1. 05 01 11 07 D** 1094 1094 1095 -Relay1 and Relay 2 will be set to N O, last 2 seconds, then change back to original state.1139 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1096 1096 1097 1097 **2. 05 01 10 07 D0** 1098 1098 1099 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then both change back to original state.1143 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state. 1100 1100 1101 1101 **3. 05 00 01 07 D0** 1102 1102 1103 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then relay change to NO,C.1147 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO. 1104 1104 1105 1105 **4. 05 00 00 07 D0** 1106 1106 1107 -Relay 1 & relay2 will change to N C, last 2 seconds, then both change to NO.1151 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC. 1108 1108 1109 1109 1110 1110 ... ... @@ -1111,6 +1111,7 @@ 1111 1111 1112 1112 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1113 1113 1158 + 1114 1114 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1115 1115 1116 1116 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1127,6 +1127,7 @@ 1127 1127 1128 1128 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1129 1129 1175 + 1130 1130 * (% style="color:#037691" %)**AT Command:** 1131 1131 1132 1132 **AT+SETCNT=aa,(bb cc dd ee) ** ... ... @@ -1149,6 +1149,7 @@ 1149 1149 1150 1150 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1151 1151 1198 + 1152 1152 Clear counting for counting mode 1153 1153 1154 1154 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1165,6 +1165,7 @@ 1165 1165 1166 1166 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1167 1167 1215 + 1168 1168 * (% style="color:#037691" %)**AT Command:** 1169 1169 1170 1170 **AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) ... ... @@ -1184,6 +1184,7 @@ 1184 1184 1185 1185 == 3.5 Integrate with Mydevice == 1186 1186 1235 + 1187 1187 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: 1188 1188 1189 1189 ((( ... ... @@ -1192,14 +1192,15 @@ 1192 1192 1193 1193 ((( 1194 1194 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1244 + 1245 + 1195 1195 ))) 1196 1196 1197 -[[image:1 653356737703-362.png||height="232" width="732"]]1248 +[[image:image-20220719105525-1.png||height="377" width="677"]] 1198 1198 1199 -[[image:image-20220524094641-11.png||height="390" width="723"]] 1200 1200 1201 1201 1202 -[[image:image-20220 524094641-12.png||height="402" width="718"]]1252 +[[image:image-20220719110247-2.png||height="388" width="683"]] 1203 1203 1204 1204 1205 1205 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. ... ... @@ -1232,8 +1232,10 @@ 1232 1232 1233 1233 == 3.6 Interface Detail == 1234 1234 1285 + 1235 1235 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1236 1236 1288 + 1237 1237 Support NPN Type sensor 1238 1238 1239 1239 [[image:1653356991268-289.png]] ... ... @@ -1242,6 +1242,7 @@ 1242 1242 1243 1243 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1244 1244 1297 + 1245 1245 ((( 1246 1246 The DI port of LT-22222-L can support NPN or PNP output sensor. 1247 1247 ))) ... ... @@ -1248,7 +1248,9 @@ 1248 1248 1249 1249 ((( 1250 1250 ((( 1251 -Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high 1304 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high. 1305 + 1306 + 1252 1252 ))) 1253 1253 ))) 1254 1254 ... ... @@ -1293,6 +1293,8 @@ 1293 1293 1294 1294 ((( 1295 1295 1351 + 1352 + 1296 1296 ))) 1297 1297 1298 1298 ((( ... ... @@ -1324,6 +1324,8 @@ 1324 1324 1325 1325 ((( 1326 1326 1384 + 1385 + 1327 1327 ))) 1328 1328 1329 1329 ((( ... ... @@ -1357,6 +1357,7 @@ 1357 1357 1358 1358 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1359 1359 1419 + 1360 1360 NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1361 1361 1362 1362 [[image:1653357531600-905.png]] ... ... @@ -1365,6 +1365,7 @@ 1365 1365 1366 1366 === 3.6.4 Analog Input Interface === 1367 1367 1428 + 1368 1368 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: 1369 1369 1370 1370 ... ... @@ -1396,6 +1396,7 @@ 1396 1396 1397 1397 === 3.6.5 Relay Output === 1398 1398 1460 + 1399 1399 ((( 1400 1400 The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1401 1401 ))) ... ... @@ -1408,6 +1408,7 @@ 1408 1408 1409 1409 == 3.7 LEDs Indicators == 1410 1410 1473 + 1411 1411 [[image:image-20220524100748-11.png]] 1412 1412 1413 1413 ... ... @@ -1414,8 +1414,10 @@ 1414 1414 1415 1415 = 4. Use AT Command = 1416 1416 1480 + 1417 1417 == 4.1 Access AT Command == 1418 1418 1483 + 1419 1419 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1420 1420 1421 1421 [[image:1653358238933-385.png]] ... ... @@ -1620,6 +1620,7 @@ 1620 1620 1621 1621 == 4.2 Common AT Command Sequence == 1622 1622 1688 + 1623 1623 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1624 1624 1625 1625 ((( ... ... @@ -1743,13 +1743,16 @@ 1743 1743 1744 1744 === 4.2.3 Change to Class A === 1745 1745 1812 + 1746 1746 If sensor JOINED 1747 1747 (% style="background-color:#dcdcdc" %)AT+CLASS=A 1748 1748 ATZ 1749 1749 1750 1750 1818 + 1751 1751 = 5. FAQ = 1752 1752 1821 + 1753 1753 == 5.1 How to upgrade the image? == 1754 1754 1755 1755 ... ... @@ -1772,6 +1772,8 @@ 1772 1772 1773 1773 (% style="color:blue" %)**For LT-22222-L**(%%): 1774 1774 Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1844 + 1845 + 1775 1775 ))) 1776 1776 1777 1777 [[image:image-20220524103407-12.png]] ... ... @@ -1783,6 +1783,7 @@ 1783 1783 1784 1784 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1785 1785 1857 + 1786 1786 [[image:1653360054704-518.png||height="186" width="745"]] 1787 1787 1788 1788 ... ... @@ -1791,6 +1791,8 @@ 1791 1791 1792 1792 1793 1793 == 5.2 How to change the LoRa Frequency Bands/Region? == 1866 + 1867 + 1794 1794 ))) 1795 1795 ))) 1796 1796 ... ... @@ -1801,7 +1801,10 @@ 1801 1801 ((( 1802 1802 1803 1803 1878 + 1804 1804 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 1880 + 1881 + 1805 1805 ))) 1806 1806 1807 1807 ((( ... ... @@ -1819,7 +1819,7 @@ 1819 1819 ))) 1820 1820 1821 1821 ((( 1822 -(% style="color: #4f81bd" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.1899 +(% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 1823 1823 ))) 1824 1824 1825 1825 ((( ... ... @@ -1827,12 +1827,12 @@ 1827 1827 ))) 1828 1828 1829 1829 ((( 1830 -(% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 1907 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.** 1831 1831 ))) 1832 1832 1833 1833 1834 1834 ((( 1835 -(% style="color: #4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:1912 +(% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 1836 1836 ))) 1837 1837 1838 1838 ((( ... ... @@ -1856,16 +1856,21 @@ 1856 1856 [[image:1653360498588-932.png||height="485" width="726"]] 1857 1857 1858 1858 1936 + 1859 1859 == 5.4 Can I see counting event in Serial? == 1860 1860 1939 + 1861 1861 ((( 1862 -User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn ’t support AT+DEBUG. User can update to latest firmware first.1941 +User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 1863 1863 1864 1864 1944 + 1865 1865 == 5.5 Can i use point to point communication for LT-22222-L? == 1866 1866 1947 + 1867 1867 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1868 1868 1950 + 1869 1869 1870 1870 ))) 1871 1871 ... ... @@ -1872,6 +1872,7 @@ 1872 1872 ((( 1873 1873 == 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1874 1874 1957 + 1875 1875 If the device is not shut down, but directly powered off. 1876 1876 1877 1877 It will default that this is a power-off state. ... ... @@ -1881,6 +1881,7 @@ 1881 1881 After restart, the status before power failure will be read from flash. 1882 1882 1883 1883 1967 + 1884 1884 = 6. Trouble Shooting = 1885 1885 ))) 1886 1886 ... ... @@ -1887,6 +1887,8 @@ 1887 1887 ((( 1888 1888 ((( 1889 1889 == 6.1 Downlink doesn't work, how to solve it? == 1974 + 1975 + 1890 1890 ))) 1891 1891 ))) 1892 1892 ... ... @@ -1897,7 +1897,10 @@ 1897 1897 ((( 1898 1898 1899 1899 1986 + 1900 1900 == 6.2 Have trouble to upload image. == 1988 + 1989 + 1901 1901 ))) 1902 1902 1903 1903 ((( ... ... @@ -1907,7 +1907,10 @@ 1907 1907 ((( 1908 1908 1909 1909 1999 + 1910 1910 == 6.3 Why I can't join TTN in US915 /AU915 bands? == 2001 + 2002 + 1911 1911 ))) 1912 1912 1913 1913 ((( ... ... @@ -1915,23 +1915,27 @@ 1915 1915 ))) 1916 1916 1917 1917 2010 + 1918 1918 = 7. Order Info = 1919 1919 2013 + 1920 1920 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1921 1921 1922 - 1923 1923 (% style="color:#4f81bd" %)**XXX:** 1924 1924 1925 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331926 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681927 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201928 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701929 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231930 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151931 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151932 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651933 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7792018 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 2019 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 2020 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 2021 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 2022 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 2023 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 2024 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 2025 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2026 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1934 1934 2028 + 2029 + 2030 + 1935 1935 = 8. Packing Info = 1936 1936 1937 1937 ... ... @@ -1949,8 +1949,12 @@ 1949 1949 * Package Size / pcs : 14.5 x 8 x 5 cm 1950 1950 * Weight / pcs : 170g 1951 1951 2048 + 2049 + 2050 + 1952 1952 = 9. Support = 1953 1953 2053 + 1954 1954 * ((( 1955 1955 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1956 1956 ))) ... ... @@ -1959,12 +1959,15 @@ 1959 1959 1960 1960 1961 1961 2062 + 1962 1962 1963 1963 ))) 1964 1964 1965 1965 = 10. Reference = 1966 1966 2068 + 1967 1967 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 1968 -* [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 1969 -* [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2070 +* [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 1970 1970 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2072 + 2073 +
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.9 KB - Content