Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -36,11 +36,13 @@ 36 36 ))) 37 37 38 38 ((( 39 -1) If user ’s area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless.39 +1) If user's area has LoRaWAN service coverage, they can just install the I/O controller and configure it to connect the LoRaWAN provider via wireless. 40 40 ))) 41 41 42 42 ((( 43 43 2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless. 44 + 45 + 44 44 ))) 45 45 46 46 ((( ... ... @@ -166,11 +166,13 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 171 + 169 169 170 170 ))) 171 171 172 172 == 1.3 Features == 173 173 177 + 174 174 * LoRaWAN Class A & Class C protocol 175 175 * Optional Customized LoRa Protocol 176 176 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 ... ... @@ -179,8 +179,13 @@ 179 179 * Firmware upgradable via program port 180 180 * Counting 181 181 186 + 187 + 188 + 189 + 182 182 == 1.4 Applications == 183 183 192 + 184 184 * Smart Buildings & Home Automation 185 185 * Logistics and Supply Chain Management 186 186 * Smart Metering ... ... @@ -188,8 +188,13 @@ 188 188 * Smart Cities 189 189 * Smart Factory 190 190 200 + 201 + 202 + 203 + 191 191 == 1.5 Hardware Variants == 192 192 206 + 193 193 (% border="1" style="background-color:#f7faff; width:500px" %) 194 194 |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 195 195 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( ... ... @@ -201,8 +201,12 @@ 201 201 * 1 x Counting Port 202 202 ))) 203 203 218 + 219 + 220 + 204 204 = 2. Power ON Device = 205 205 223 + 206 206 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 207 207 208 208 ((( ... ... @@ -217,6 +217,7 @@ 217 217 218 218 == 3.1 How it works? == 219 219 238 + 220 220 ((( 221 221 The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 222 222 ))) ... ... @@ -226,10 +226,14 @@ 226 226 ))) 227 227 228 228 248 + 229 229 == 3.2 Example to join LoRaWAN network == 230 230 251 + 231 231 ((( 232 232 This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 254 + 255 + 233 233 ))) 234 234 235 235 [[image:image-20220523172350-1.png||height="266" width="864"]] ... ... @@ -237,6 +237,8 @@ 237 237 238 238 ((( 239 239 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 263 + 264 + 240 240 ))) 241 241 242 242 ((( ... ... @@ -262,6 +262,7 @@ 262 262 [[image:1653298023685-319.png]] 263 263 264 264 290 + 265 265 ((( 266 266 (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 267 267 ))) ... ... @@ -272,6 +272,7 @@ 272 272 273 273 == 3.3 Uplink Payload == 274 274 301 + 275 275 There are five working modes + one interrupt mode on LT for different type application: 276 276 277 277 * (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO ... ... @@ -283,8 +283,11 @@ 283 283 284 284 285 285 313 + 314 + 286 286 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 287 287 317 + 288 288 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 289 289 290 290 [[image:image-20220523174024-3.png]] ... ... @@ -321,8 +321,6 @@ 321 321 * [1] RO1 relay channel is close and the RO1 LED is ON. 322 322 * [0] RO2 relay channel is open and RO2 LED is OFF; 323 323 324 - 325 - 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -340,6 +340,8 @@ 340 340 341 341 342 342 371 + 372 + 343 343 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 344 344 345 345 ... ... @@ -408,6 +408,7 @@ 408 408 409 409 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 410 410 441 + 411 411 **LT22222-L**: This mode the DI1 is used as a counting pin. 412 412 413 413 [[image:image-20220523181246-5.png]] ... ... @@ -569,7 +569,6 @@ 569 569 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 570 570 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 571 571 572 - 573 573 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 574 574 575 575 ... ... @@ -694,14 +694,14 @@ 694 694 ((( 695 695 696 696 697 -**Decoder for TTN/loraserver/ChirpStack**: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/Payload_decoder/]] 698 - 699 - 727 +**Decoder for TTN/loraserver/ChirpStack**: [[https:~~/~~/www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0>>https://www.dropbox.com/sh/wtrzu7avdtkmn3z/AACK5NwOMkU9jnvf1uCMuqrVa?dl=0]] 700 700 ))) 701 701 702 702 731 + 703 703 == 3.4 Configure LT via AT or Downlink == 704 704 734 + 705 705 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 706 706 707 707 ((( ... ... @@ -714,8 +714,10 @@ 714 714 715 715 716 716 747 + 717 717 === 3.4.1 Common Commands === 718 718 750 + 719 719 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 720 720 721 721 ... ... @@ -722,8 +722,10 @@ 722 722 723 723 === 3.4.2 Sensor related commands === 724 724 757 + 725 725 ==== 3.4.2.1 Set Transmit Interval ==== 726 726 760 + 727 727 Set device uplink interval. 728 728 729 729 * (% style="color:#037691" %)**AT Command:** ... ... @@ -743,6 +743,7 @@ 743 743 744 744 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 745 745 780 + 746 746 Set work mode. 747 747 748 748 * (% style="color:#037691" %)**AT Command:** ... ... @@ -762,6 +762,7 @@ 762 762 763 763 ==== 3.4.2.3 Poll an uplink ==== 764 764 800 + 765 765 * (% style="color:#037691" %)**AT Command:** 766 766 767 767 There is no AT Command to poll uplink ... ... @@ -775,8 +775,10 @@ 775 775 776 776 777 777 814 + 778 778 ==== 3.4.2.4 Enable Trigger Mode ==== 779 779 817 + 780 780 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 781 781 782 782 * (% style="color:#037691" %)**AT Command:** ... ... @@ -797,6 +797,7 @@ 797 797 798 798 ==== 3.4.2.5 Poll trigger settings ==== 799 799 838 + 800 800 Poll trigger settings, 801 801 802 802 * (% style="color:#037691" %)**AT Command:** ... ... @@ -813,6 +813,7 @@ 813 813 814 814 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 815 815 855 + 816 816 Enable Disable DI1/DI2/DI2 as trigger, 817 817 818 818 * (% style="color:#037691" %)**AT Command:** ... ... @@ -833,6 +833,7 @@ 833 833 834 834 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 835 835 876 + 836 836 Set DI1 or DI3(for LT-33222-L) trigger. 837 837 838 838 * (% style="color:#037691" %)**AT Command:** ... ... @@ -852,8 +852,13 @@ 852 852 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 853 853 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 854 854 896 + 897 + 898 + 899 + 855 855 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 856 856 902 + 857 857 Set DI2 trigger. 858 858 859 859 * (% style="color:#037691" %)**AT Command:** ... ... @@ -880,6 +880,7 @@ 880 880 881 881 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 882 882 929 + 883 883 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 884 884 885 885 * (% style="color:#037691" %)**AT Command** ... ... @@ -896,6 +896,7 @@ 896 896 897 897 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 898 898 946 + 899 899 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 900 900 901 901 * (% style="color:#037691" %)**AT Command** ... ... @@ -912,6 +912,7 @@ 912 912 913 913 ==== 3.4.2.11 Trigger – Set minimum interval ==== 914 914 963 + 915 915 Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 916 916 917 917 * (% style="color:#037691" %)**AT Command** ... ... @@ -931,8 +931,10 @@ 931 931 932 932 933 933 983 + 934 934 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 935 935 986 + 936 936 * (% style="color:#037691" %)**AT Command** 937 937 938 938 There is no AT Command to control Digital Output ... ... @@ -964,6 +964,7 @@ 964 964 965 965 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 966 966 1018 + 967 967 * (% style="color:#037691" %)**AT Command** 968 968 969 969 There is no AT Command to control Digital Output ... ... @@ -1030,6 +1030,7 @@ 1030 1030 1031 1031 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1032 1032 1085 + 1033 1033 * (% style="color:#037691" %)**AT Command:** 1034 1034 1035 1035 There is no AT Command to control Relay Output ... ... @@ -1059,6 +1059,7 @@ 1059 1059 1060 1060 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1061 1061 1115 + 1062 1062 * (% style="color:#037691" %)**AT Command:** 1063 1063 1064 1064 There is no AT Command to control Relay Output ... ... @@ -1082,7 +1082,7 @@ 1082 1082 1083 1083 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1084 1084 1085 -[[image:image-20220 524093831-10.png]]1139 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1086 1086 1087 1087 1088 1088 (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms ... ... @@ -1092,21 +1092,21 @@ 1092 1092 1093 1093 **Example payload:** 1094 1094 1095 -**~1. 05 01 11 07 D 0**1149 +**~1. 05 01 11 07 D** 1096 1096 1097 -Relay1 and Relay 2 will be set to N O, last 2 seconds, then change back to original state.1151 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1098 1098 1099 1099 **2. 05 01 10 07 D0** 1100 1100 1101 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then both change back to original state.1155 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state. 1102 1102 1103 1103 **3. 05 00 01 07 D0** 1104 1104 1105 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then relay change to NO,C.1159 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO. 1106 1106 1107 1107 **4. 05 00 00 07 D0** 1108 1108 1109 -Relay 1 & relay2 will change to N C, last 2 seconds, then both change to NO.1163 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC. 1110 1110 1111 1111 1112 1112 ... ... @@ -1113,6 +1113,7 @@ 1113 1113 1114 1114 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1115 1115 1170 + 1116 1116 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1117 1117 1118 1118 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1129,6 +1129,7 @@ 1129 1129 1130 1130 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1131 1131 1187 + 1132 1132 * (% style="color:#037691" %)**AT Command:** 1133 1133 1134 1134 **AT+SETCNT=aa,(bb cc dd ee) ** ... ... @@ -1151,6 +1151,7 @@ 1151 1151 1152 1152 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1153 1153 1210 + 1154 1154 Clear counting for counting mode 1155 1155 1156 1156 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1167,6 +1167,7 @@ 1167 1167 1168 1168 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1169 1169 1227 + 1170 1170 * (% style="color:#037691" %)**AT Command:** 1171 1171 1172 1172 **AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) ... ... @@ -1186,6 +1186,7 @@ 1186 1186 1187 1187 == 3.5 Integrate with Mydevice == 1188 1188 1247 + 1189 1189 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: 1190 1190 1191 1191 ((( ... ... @@ -1194,14 +1194,15 @@ 1194 1194 1195 1195 ((( 1196 1196 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1256 + 1257 + 1197 1197 ))) 1198 1198 1199 -[[image:1 653356737703-362.png||height="232" width="732"]]1260 +[[image:image-20220719105525-1.png||height="377" width="677"]] 1200 1200 1201 -[[image:image-20220524094641-11.png||height="390" width="723"]] 1202 1202 1203 1203 1204 -[[image:image-20220 524094641-12.png||height="402" width="718"]]1264 +[[image:image-20220719110247-2.png||height="388" width="683"]] 1205 1205 1206 1206 1207 1207 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. ... ... @@ -1234,8 +1234,10 @@ 1234 1234 1235 1235 == 3.6 Interface Detail == 1236 1236 1297 + 1237 1237 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1238 1238 1300 + 1239 1239 Support NPN Type sensor 1240 1240 1241 1241 [[image:1653356991268-289.png]] ... ... @@ -1244,6 +1244,7 @@ 1244 1244 1245 1245 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1246 1246 1309 + 1247 1247 ((( 1248 1248 The DI port of LT-22222-L can support NPN or PNP output sensor. 1249 1249 ))) ... ... @@ -1250,7 +1250,9 @@ 1250 1250 1251 1251 ((( 1252 1252 ((( 1253 -Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high 1316 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high. 1317 + 1318 + 1254 1254 ))) 1255 1255 ))) 1256 1256 ... ... @@ -1295,6 +1295,8 @@ 1295 1295 1296 1296 ((( 1297 1297 1363 + 1364 + 1298 1298 ))) 1299 1299 1300 1300 ((( ... ... @@ -1326,6 +1326,8 @@ 1326 1326 1327 1327 ((( 1328 1328 1396 + 1397 + 1329 1329 ))) 1330 1330 1331 1331 ((( ... ... @@ -1359,6 +1359,7 @@ 1359 1359 1360 1360 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1361 1361 1431 + 1362 1362 NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1363 1363 1364 1364 [[image:1653357531600-905.png]] ... ... @@ -1367,6 +1367,7 @@ 1367 1367 1368 1368 === 3.6.4 Analog Input Interface === 1369 1369 1440 + 1370 1370 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: 1371 1371 1372 1372 ... ... @@ -1398,6 +1398,7 @@ 1398 1398 1399 1399 === 3.6.5 Relay Output === 1400 1400 1472 + 1401 1401 ((( 1402 1402 The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1403 1403 ))) ... ... @@ -1410,6 +1410,7 @@ 1410 1410 1411 1411 == 3.7 LEDs Indicators == 1412 1412 1485 + 1413 1413 [[image:image-20220524100748-11.png]] 1414 1414 1415 1415 ... ... @@ -1416,8 +1416,10 @@ 1416 1416 1417 1417 = 4. Use AT Command = 1418 1418 1492 + 1419 1419 == 4.1 Access AT Command == 1420 1420 1495 + 1421 1421 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1422 1422 1423 1423 [[image:1653358238933-385.png]] ... ... @@ -1622,6 +1622,7 @@ 1622 1622 1623 1623 == 4.2 Common AT Command Sequence == 1624 1624 1700 + 1625 1625 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1626 1626 1627 1627 ((( ... ... @@ -1732,6 +1732,8 @@ 1732 1732 2. Make sure the LG01/02 gateway RX frequency is exactly the same as AT+CHS setting. 1733 1733 3. Make sure SF / bandwidth setting in LG01/LG02 match the settings of AT+DR. refer [[this link>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_Gateway/&file=LoRaWAN%201.0.3%20Regional%20Parameters.xlsx]] to see what DR means. 1734 1734 4. The command AT+RX2FQ and AT+RX2DR is to let downlink work. to set the correct parameters, user can check the actually downlink parameters to be used. As below. Which shows the RX2FQ should use 868400000 and RX2DR should be 5 1811 + 1812 + 1735 1735 ))) 1736 1736 1737 1737 ((( ... ... @@ -1745,13 +1745,16 @@ 1745 1745 1746 1746 === 4.2.3 Change to Class A === 1747 1747 1826 + 1748 1748 If sensor JOINED 1749 1749 (% style="background-color:#dcdcdc" %)AT+CLASS=A 1750 1750 ATZ 1751 1751 1752 1752 1832 + 1753 1753 = 5. FAQ = 1754 1754 1835 + 1755 1755 == 5.1 How to upgrade the image? == 1756 1756 1757 1757 ... ... @@ -1773,7 +1773,9 @@ 1773 1773 1774 1774 1775 1775 (% style="color:blue" %)**For LT-22222-L**(%%): 1776 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1857 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1858 + 1859 + 1777 1777 ))) 1778 1778 1779 1779 [[image:image-20220524103407-12.png]] ... ... @@ -1785,6 +1785,7 @@ 1785 1785 1786 1786 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1787 1787 1871 + 1788 1788 [[image:1653360054704-518.png||height="186" width="745"]] 1789 1789 1790 1790 ... ... @@ -1793,6 +1793,8 @@ 1793 1793 1794 1794 1795 1795 == 5.2 How to change the LoRa Frequency Bands/Region? == 1880 + 1881 + 1796 1796 ))) 1797 1797 ))) 1798 1798 ... ... @@ -1803,7 +1803,10 @@ 1803 1803 ((( 1804 1804 1805 1805 1892 + 1806 1806 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 1894 + 1895 + 1807 1807 ))) 1808 1808 1809 1809 ((( ... ... @@ -1821,7 +1821,7 @@ 1821 1821 ))) 1822 1822 1823 1823 ((( 1824 -(% style="color: #4f81bd" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.1913 +(% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 1825 1825 ))) 1826 1826 1827 1827 ((( ... ... @@ -1829,12 +1829,12 @@ 1829 1829 ))) 1830 1830 1831 1831 ((( 1832 -(% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 1921 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.** 1833 1833 ))) 1834 1834 1835 1835 1836 1836 ((( 1837 -(% style="color: #4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:1926 +(% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 1838 1838 ))) 1839 1839 1840 1840 ((( ... ... @@ -1858,16 +1858,21 @@ 1858 1858 [[image:1653360498588-932.png||height="485" width="726"]] 1859 1859 1860 1860 1950 + 1861 1861 == 5.4 Can I see counting event in Serial? == 1862 1862 1953 + 1863 1863 ((( 1864 -User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn ’t support AT+DEBUG. User can update to latest firmware first.1955 +User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 1865 1865 1866 1866 1958 + 1867 1867 == 5.5 Can i use point to point communication for LT-22222-L? == 1868 1868 1961 + 1869 1869 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1870 1870 1964 + 1871 1871 1872 1872 ))) 1873 1873 ... ... @@ -1874,6 +1874,7 @@ 1874 1874 ((( 1875 1875 == 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1876 1876 1971 + 1877 1877 If the device is not shut down, but directly powered off. 1878 1878 1879 1879 It will default that this is a power-off state. ... ... @@ -1883,12 +1883,15 @@ 1883 1883 After restart, the status before power failure will be read from flash. 1884 1884 1885 1885 1981 + 1886 1886 = 6. Trouble Shooting = 1887 1887 ))) 1888 1888 1889 1889 ((( 1890 1890 ((( 1891 -== 6.1 Downlink doesn’t work, how to solve it? == 1987 +== 6.1 Downlink doesn't work, how to solve it? == 1988 + 1989 + 1892 1892 ))) 1893 1893 ))) 1894 1894 ... ... @@ -1899,7 +1899,10 @@ 1899 1899 ((( 1900 1900 1901 1901 2000 + 1902 1902 == 6.2 Have trouble to upload image. == 2002 + 2003 + 1903 1903 ))) 1904 1904 1905 1905 ((( ... ... @@ -1909,7 +1909,10 @@ 1909 1909 ((( 1910 1910 1911 1911 1912 -== 6.3 Why I can’t join TTN in US915 /AU915 bands? == 2013 + 2014 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 2015 + 2016 + 1913 1913 ))) 1914 1914 1915 1915 ((( ... ... @@ -1917,23 +1917,26 @@ 1917 1917 ))) 1918 1918 1919 1919 2024 + 1920 1920 = 7. Order Info = 1921 1921 2027 + 1922 1922 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1923 1923 1924 - 1925 1925 (% style="color:#4f81bd" %)**XXX:** 1926 1926 1927 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331928 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681929 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201930 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701931 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231932 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151933 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151934 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651935 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7792032 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 2033 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 2034 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 2035 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 2036 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 2037 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 2038 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 2039 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2040 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1936 1936 2042 + 2043 + 1937 1937 = 8. Packing Info = 1938 1938 1939 1939 ... ... @@ -1951,8 +1951,11 @@ 1951 1951 * Package Size / pcs : 14.5 x 8 x 5 cm 1952 1952 * Weight / pcs : 170g 1953 1953 2061 + 2062 + 1954 1954 = 9. Support = 1955 1955 2065 + 1956 1956 * ((( 1957 1957 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1958 1958 ))) ... ... @@ -1966,7 +1966,9 @@ 1966 1966 1967 1967 = 10. Reference = 1968 1968 2079 + 1969 1969 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 1970 -* [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 1971 -* [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2081 +* [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 1972 1972 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2083 + 2084 +
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.9 KB - Content