... ... @@ -413,8 +413,6 @@
413 413  [[image:image-20220523181246-5.png]]
414 414  
415 415  (((
416 -
417 -
418 418  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
419 419  )))
420 420  
... ... @@ -428,7 +428,6 @@
428 428  (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
429 429  )))
430 430  
431 -
432 432  (((
433 433  **To use counting mode, please run:**
434 434  )))
... ... @@ -561,8 +561,8 @@
561 561  
562 562  For example, if user has configured below commands:
563 563  
564 -* **AT+MOD=1 ** **~-~->**  The normal working mode
565 -* **AT+ADDMOD6=1**   **~-~->**  Enable trigger
561 +* **AT+MOD=1 ** **~-~->** The normal working mode
562 +* **AT+ADDMOD6=1**   **~-~->** Enable trigger
566 566  
567 567  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
568 568  
... ... @@ -569,10 +569,8 @@
569 569  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
570 570  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
571 571  
572 -
573 573  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
574 574  
575 -
576 576  (% style="color:#4f81bd" %)**Trigger base on voltage**:
577 577  
578 578  Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH>
... ... @@ -712,8 +712,6 @@
712 712  
713 713  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below: