Summary

Details

Page properties
Content
... ... @@ -179,6 +179,7 @@
179 179  * Firmware upgradable via program port
180 180  * Counting
181 181  
182 +
182 182  == 1.4  Applications ==
183 183  
184 184  * Smart Buildings & Home Automation
... ... @@ -188,6 +188,7 @@
188 188  * Smart Cities
189 189  * Smart Factory
190 190  
192 +
191 191  == 1.5 Hardware Variants ==
192 192  
193 193  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -201,6 +201,7 @@
201 201  * 1 x Counting Port
202 202  )))
203 203  
206 +
204 204  = 2. Power ON Device =
205 205  
206 206  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -274,12 +274,12 @@
274 274  
275 275  There are five working modes + one interrupt mode on LT for different type application:
276 276  
277 -* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
278 -* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO
279 -* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
280 -* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
281 -* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
282 -* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
280 +* **(% style="color:blue" %)MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
281 +* **(% style="color:blue" %)MOD2**(%%): Double DI Counting + DO + RO
282 +* **(% style="color:blue" %)MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
283 +* **(% style="color:blue" %)MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
284 +* **(% style="color:blue" %)MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
285 +* **(% style="color:blue" %)ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
283 283  
284 284  
285 285  
... ... @@ -321,8 +321,6 @@
321 321  * [1] RO1 relay channel is close and the RO1 LED is ON.
322 322  * [0] RO2 relay channel is open and RO2 LED is OFF;
323 323  
324 -
325 -
326 326  **LT22222-L:**
327 327  
328 328  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -338,8 +338,6 @@
338 338  ** DO1 is high in case there is load between DO1 and V+.
339 339  ** DO1 LED is off in both case
340 340  
341 -
342 -
343 343  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
344 344  
345 345  
... ... @@ -413,8 +413,6 @@
413 413  [[image:image-20220523181246-5.png]]
414 414  
415 415  (((
416 -
417 -
418 418  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
419 419  )))
420 420  
... ... @@ -428,7 +428,6 @@
428 428  (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
429 429  )))
430 430  
431 -
432 432  (((
433 433  **To use counting mode, please run:**
434 434  )))
... ... @@ -561,8 +561,8 @@
561 561  
562 562  For example, if user has configured below commands:
563 563  
564 -* **AT+MOD=1 ** **~-~->**  The normal working mode
565 -* **AT+ADDMOD6=1**   **~-~->**  Enable trigger
560 +* **AT+MOD=1 ** **~-~->** The normal working mode
561 +* **AT+ADDMOD6=1**   **~-~->** Enable trigger
566 566  
567 567  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
568 568  
... ... @@ -569,10 +569,8 @@
569 569  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
570 570  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
571 571  
572 -
573 573  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
574 574  
575 -
576 576  (% style="color:#4f81bd" %)**Trigger base on voltage**:
577 577  
578 578  Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH>
... ... @@ -712,8 +712,6 @@
712 712  
713 713  * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L.  User can see these commands below:
714 714  
715 -
716 -
717 717  === 3.4.1 Common Commands ===
718 718  
719 719  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]