Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,6 +1,7 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 +**LT-22222-L LoRa IO Controller User Manual ** 4 4 5 5 6 6 **Table of Contents:** ... ... @@ -166,6 +166,7 @@ 166 166 Packet engine up to 256 bytes with CRC. 167 167 168 168 170 + 169 169 170 170 ))) 171 171 ... ... @@ -201,6 +201,8 @@ 201 201 * 1 x Counting Port 202 202 ))) 203 203 206 + 207 + 204 204 = 2. Power ON Device = 205 205 206 206 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -218,11 +218,11 @@ 218 218 == 3.1 How it works? == 219 219 220 220 ((( 221 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%)will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network.(% style="color:green" %)**TX LED**(%%)will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second.225 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 222 222 ))) 223 223 224 224 ((( 225 -In case user can 't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.229 +In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 226 226 ))) 227 227 228 228 ... ... @@ -274,15 +274,13 @@ 274 274 275 275 There are five working modes + one interrupt mode on LT for different type application: 276 276 277 -* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO278 -* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO279 -* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO280 -* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO281 -* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO282 -* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5281 +* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 282 +* **MOD2**: Double DI Counting + DO + RO 283 +* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 284 +* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 285 +* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 +* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 283 283 284 - 285 - 286 286 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 287 287 288 288 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -321,8 +321,6 @@ 321 321 * [1] RO1 relay channel is close and the RO1 LED is ON. 322 322 * [0] RO2 relay channel is open and RO2 LED is OFF; 323 323 324 - 325 - 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -338,8 +338,6 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 341 - 342 - 343 343 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 344 344 345 345 ... ... @@ -413,8 +413,6 @@ 413 413 [[image:image-20220523181246-5.png]] 414 414 415 415 ((( 416 - 417 - 418 418 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 419 419 ))) 420 420 ... ... @@ -428,7 +428,6 @@ 428 428 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 429 429 ))) 430 430 431 - 432 432 ((( 433 433 **To use counting mode, please run:** 434 434 ))) ... ... @@ -561,8 +561,8 @@ 561 561 562 562 For example, if user has configured below commands: 563 563 564 -* **AT+MOD=1 ** 565 -* **AT+ADDMOD6=1** **~-~->** 559 +* **AT+MOD=1 ** **~-~->** The normal working mode 560 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 566 566 567 567 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 568 568 ... ... @@ -572,7 +572,6 @@ 572 572 573 573 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 574 574 575 - 576 576 (% style="color:#4f81bd" %)**Trigger base on voltage**: 577 577 578 578 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -712,8 +712,6 @@ 712 712 713 713 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 714 714 715 - 716 - 717 717 === 3.4.1 Common Commands === 718 718 719 719 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -799,23 +799,25 @@ 799 799 800 800 Poll trigger settings, 801 801 802 -* (% style="color:#037691" %) **AT Command:**794 +* (% style="color:#037691" %)AT Command: 803 803 804 804 There is no AT Command for this feature. 805 805 806 806 807 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**799 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 808 808 809 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 801 +(% class="box infomessage" %) 802 +((( 803 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 804 +))) 810 810 811 811 812 812 813 - 814 814 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 815 815 816 816 Enable Disable DI1/DI2/DI2 as trigger, 817 817 818 -* (% style="color:#037691" %) **AT Command:**812 +* (% style="color:#037691" %)AT Command: 819 819 820 820 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 821 821 ... ... @@ -824,7 +824,7 @@ 824 824 825 825 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 826 826 827 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**821 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 828 828 829 829 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 830 830 ... ... @@ -835,7 +835,7 @@ 835 835 836 836 Set DI1 or DI3(for LT-33222-L) trigger. 837 837 838 -* (% style="color:#037691" %) **AT Command:**832 +* (% style="color:#037691" %)AT Command: 839 839 840 840 **AT+TRIG1=a,b** 841 841 ... ... @@ -852,6 +852,7 @@ 852 852 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 853 853 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 854 854 849 + 855 855 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 856 856 857 857 Set DI2 trigger. ... ... @@ -912,11 +912,11 @@ 912 912 913 913 ==== 3.4.2.11 Trigger – Set minimum interval ==== 914 914 915 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.910 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 916 916 917 917 * (% style="color:#037691" %)**AT Command** 918 918 919 -**AT+ATDC=5 **Device won't response the second trigger within 5 minute after the first trigger.914 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 920 920 921 921 922 922 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -923,14 +923,9 @@ 923 923 924 924 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 925 925 926 -((( 927 - 928 928 929 -(% style="color:red" %)Note: ATDC setting must be more than 5min 930 -))) 931 931 932 932 933 - 934 934 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 935 935 936 936 * (% style="color:#037691" %)**AT Command** ... ... @@ -1131,7 +1131,7 @@ 1131 1131 1132 1132 * (% style="color:#037691" %)**AT Command:** 1133 1133 1134 -**AT+SETCNT=aa,(bb cc dd ee) ** 1124 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1135 1135 1136 1136 aa: 1: Set count1, 1137 1137 ... ... @@ -1155,7 +1155,7 @@ 1155 1155 1156 1156 * (% style="color:#037691" %)**AT Command:** 1157 1157 1158 -**AT+CLRCOUNT ** ~/~/ clear all counting 1148 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1159 1159 1160 1160 1161 1161 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1413,7 +1413,6 @@ 1413 1413 [[image:image-20220524100748-11.png]] 1414 1414 1415 1415 1416 - 1417 1417 = 4. Use AT Command = 1418 1418 1419 1419 == 4.1 Access AT Command == ... ... @@ -1616,6 +1616,8 @@ 1616 1616 1617 1617 ((( 1618 1618 AT+CFG: Print all settings 1608 + 1609 + 1619 1619 ))) 1620 1620 1621 1621 ... ... @@ -1661,6 +1661,8 @@ 1661 1661 1662 1662 ((( 1663 1663 (% style="background-color:#dcdcdc" %)ATZ 1655 + 1656 + 1664 1664 ))) 1665 1665 1666 1666 ... ... @@ -1867,8 +1867,6 @@ 1867 1867 == 5.5 Can i use point to point communication for LT-22222-L? == 1868 1868 1869 1869 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1870 - 1871 - 1872 1872 ))) 1873 1873 1874 1874 ((( ... ... @@ -1882,7 +1882,6 @@ 1882 1882 1883 1883 After restart, the status before power failure will be read from flash. 1884 1884 1885 - 1886 1886 = 6. Trouble Shooting = 1887 1887 ))) 1888 1888 ... ... @@ -1917,8 +1917,10 @@ 1917 1917 ))) 1918 1918 1919 1919 1910 + 1920 1920 = 7. Order Info = 1921 1921 1913 + 1922 1922 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1923 1923 1924 1924 ... ... @@ -1958,10 +1958,6 @@ 1958 1958 ))) 1959 1959 * ((( 1960 1960 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1961 - 1962 - 1963 - 1964 - 1965 1965 ))) 1966 1966 1967 1967 = 10. Reference =