Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -181,7 +181,6 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 - 185 185 == 1.4 Applications == 186 186 187 187 * Smart Buildings & Home Automation ... ... @@ -191,7 +191,6 @@ 191 191 * Smart Cities 192 192 * Smart Factory 193 193 194 - 195 195 == 1.5 Hardware Variants == 196 196 197 197 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -205,6 +205,8 @@ 205 205 * 1 x Counting Port 206 206 ))) 207 207 206 + 207 + 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -285,8 +285,6 @@ 285 285 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 286 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 288 - 289 - 290 290 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 291 291 292 292 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -340,8 +340,6 @@ 340 340 ** DO1 is high in case there is load between DO1 and V+. 341 341 ** DO1 LED is off in both case 342 342 343 - 344 - 345 345 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 346 346 347 347 ... ... @@ -568,6 +568,7 @@ 568 568 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 569 569 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 570 570 567 + 571 571 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 572 572 573 573 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -709,8 +709,6 @@ 709 709 710 710 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 711 711 712 - 713 - 714 714 === 3.4.1 Common Commands === 715 715 716 716 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -803,7 +803,7 @@ 803 803 804 804 * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 805 805 806 -**0xAB 06 801 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 807 807 808 808 809 809 ... ... @@ -849,6 +849,9 @@ 849 849 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 850 850 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 851 851 847 + 848 + 849 + 852 852 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 853 853 854 854 Set DI2 trigger. ... ... @@ -913,7 +913,7 @@ 913 913 914 914 * (% style="color:#037691" %)**AT Command** 915 915 916 -**AT+ATDC=5 914 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 917 917 918 918 919 919 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -920,14 +920,9 @@ 920 920 921 921 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 922 922 923 -((( 924 - 925 925 926 -(% style="color:red" %)Note: ATDC setting must be more than 5min 927 -))) 928 928 929 929 930 - 931 931 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 932 932 933 933 * (% style="color:#037691" %)**AT Command** ... ... @@ -1152,7 +1152,7 @@ 1152 1152 1153 1153 * (% style="color:#037691" %)**AT Command:** 1154 1154 1155 -**AT+CLRCOUNT ** ~/~/ clear all counting 1148 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1156 1156 1157 1157 1158 1158 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1914,8 +1914,10 @@ 1914 1914 ))) 1915 1915 1916 1916 1910 + 1917 1917 = 7. Order Info = 1918 1918 1913 + 1919 1919 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1920 1920 1921 1921 ... ... @@ -1931,6 +1931,9 @@ 1931 1931 * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1932 1932 * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1933 1933 1929 + 1930 + 1931 + 1934 1934 = 8. Packing Info = 1935 1935 1936 1936 ... ... @@ -1948,6 +1948,9 @@ 1948 1948 * Package Size / pcs : 14.5 x 8 x 5 cm 1949 1949 * Weight / pcs : 170g 1950 1950 1949 + 1950 + 1951 + 1951 1951 = 9. Support = 1952 1952 1953 1953 * (((