Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -181,7 +181,6 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 - 185 185 == 1.4 Applications == 186 186 187 187 * Smart Buildings & Home Automation ... ... @@ -191,7 +191,6 @@ 191 191 * Smart Cities 192 192 * Smart Factory 193 193 194 - 195 195 == 1.5 Hardware Variants == 196 196 197 197 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -205,6 +205,8 @@ 205 205 * 1 x Counting Port 206 206 ))) 207 207 206 + 207 + 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -285,8 +285,6 @@ 285 285 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 286 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 288 - 289 - 290 290 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 291 291 292 292 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -340,8 +340,6 @@ 340 340 ** DO1 is high in case there is load between DO1 and V+. 341 341 ** DO1 LED is off in both case 342 342 343 - 344 - 345 345 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 346 346 347 347 ... ... @@ -568,6 +568,7 @@ 568 568 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 569 569 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 570 570 567 + 571 571 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 572 572 573 573 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -709,8 +709,6 @@ 709 709 710 710 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 711 711 712 - 713 - 714 714 === 3.4.1 Common Commands === 715 715 716 716 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -796,23 +796,25 @@ 796 796 797 797 Poll trigger settings, 798 798 799 -* (% style="color:#037691" %) **AT Command:**794 +* (% style="color:#037691" %)AT Command: 800 800 801 801 There is no AT Command for this feature. 802 802 803 803 804 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**799 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 805 805 806 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 801 +(% class="box infomessage" %) 802 +((( 803 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 804 +))) 807 807 808 808 809 809 810 - 811 811 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 812 812 813 813 Enable Disable DI1/DI2/DI2 as trigger, 814 814 815 -* (% style="color:#037691" %) **AT Command:**812 +* (% style="color:#037691" %)AT Command: 816 816 817 817 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 818 818 ... ... @@ -821,7 +821,7 @@ 821 821 822 822 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 823 823 824 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**821 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 825 825 826 826 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 827 827 ... ... @@ -832,7 +832,7 @@ 832 832 833 833 Set DI1 or DI3(for LT-33222-L) trigger. 834 834 835 -* (% style="color:#037691" %) **AT Command:**832 +* (% style="color:#037691" %)AT Command: 836 836 837 837 **AT+TRIG1=a,b** 838 838 ... ... @@ -849,6 +849,7 @@ 849 849 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 850 850 * **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 851 851 849 + 852 852 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 853 853 854 854 Set DI2 trigger. ... ... @@ -909,11 +909,11 @@ 909 909 910 910 ==== 3.4.2.11 Trigger – Set minimum interval ==== 911 911 912 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.910 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 913 913 914 914 * (% style="color:#037691" %)**AT Command** 915 915 916 -**AT+ATDC=5 **Device won't response the second trigger within 5 minute after the first trigger.914 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 917 917 918 918 919 919 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -920,14 +920,9 @@ 920 920 921 921 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 922 922 923 -((( 924 - 925 925 926 -(% style="color:red" %)Note: ATDC setting must be more than 5min 927 -))) 928 928 929 929 930 - 931 931 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 932 932 933 933 * (% style="color:#037691" %)**AT Command** ... ... @@ -1128,7 +1128,7 @@ 1128 1128 1129 1129 * (% style="color:#037691" %)**AT Command:** 1130 1130 1131 -**AT+SETCNT=aa,(bb cc dd ee) ** 1124 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1132 1132 1133 1133 aa: 1: Set count1, 1134 1134 ... ... @@ -1152,7 +1152,7 @@ 1152 1152 1153 1153 * (% style="color:#037691" %)**AT Command:** 1154 1154 1155 -**AT+CLRCOUNT ** ~/~/ clear all counting 1148 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1156 1156 1157 1157 1158 1158 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1410,7 +1410,6 @@ 1410 1410 [[image:image-20220524100748-11.png]] 1411 1411 1412 1412 1413 - 1414 1414 = 4. Use AT Command = 1415 1415 1416 1416 == 4.1 Access AT Command == ... ... @@ -1613,6 +1613,8 @@ 1613 1613 1614 1614 ((( 1615 1615 AT+CFG: Print all settings 1608 + 1609 + 1616 1616 ))) 1617 1617 1618 1618 ... ... @@ -1658,6 +1658,8 @@ 1658 1658 1659 1659 ((( 1660 1660 (% style="background-color:#dcdcdc" %)ATZ 1655 + 1656 + 1661 1661 ))) 1662 1662 1663 1663 ... ... @@ -1864,8 +1864,6 @@ 1864 1864 == 5.5 Can i use point to point communication for LT-22222-L? == 1865 1865 1866 1866 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1867 - 1868 - 1869 1869 ))) 1870 1870 1871 1871 ((( ... ... @@ -1879,7 +1879,6 @@ 1879 1879 1880 1880 After restart, the status before power failure will be read from flash. 1881 1881 1882 - 1883 1883 = 6. Trouble Shooting = 1884 1884 ))) 1885 1885 ... ... @@ -1914,8 +1914,10 @@ 1914 1914 ))) 1915 1915 1916 1916 1910 + 1917 1917 = 7. Order Info = 1918 1918 1913 + 1919 1919 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1920 1920 1921 1921 ... ... @@ -1955,10 +1955,6 @@ 1955 1955 ))) 1956 1956 * ((( 1957 1957 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1958 - 1959 - 1960 - 1961 - 1962 1962 ))) 1963 1963 1964 1964 = 10. Reference =