From version < 83.1 >
edited by Bei Jinggeng
on 2022/06/28 13:36
To version < 82.19 >
edited by Xiaoling
on 2022/06/20 11:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -182,6 +182,7 @@
182 182  * Counting
183 183  
184 184  
185 +
185 185  == 1.4  Applications ==
186 186  
187 187  * Smart Buildings & Home Automation
... ... @@ -192,6 +192,7 @@
192 192  * Smart Factory
193 193  
194 194  
196 +
195 195  == 1.5 Hardware Variants ==
196 196  
197 197  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -205,6 +205,7 @@
205 205  * 1 x Counting Port
206 206  )))
207 207  
210 +
208 208  = 2. Power ON Device =
209 209  
210 210  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -391,20 +391,24 @@
391 391  
392 392  (((
393 393  **For LT22222-L:**
397 +)))
394 394  
399 +(% class="box infomessage" %)
400 +(((
401 +(((
402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
395 395  
396 -(% style="color:blue" %)**AT+TRIG1=0,100**(%%)**  (set DI1 port to trigger on low level, valid signal is 100ms) **
404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
397 397  
398 -(% style="color:blue" %)**AT+TRIG1=1,100**(%%)**  (set DI1 port to trigger on high level, valid signal is 100ms ) **
406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
399 399  
400 -(% style="color:blue" %)**AT+TRIG2=0,100**(%%)**  (set DI2 port to trigger on low level, valid signal is 100ms) **
408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
401 401  
402 -(% style="color:blue" %)**AT+TRIG2=1,100**(%%)**  (set DI2 port to trigger on high level, valid signal is 100ms ) **
410 +**AT+SETCNT=1,6  (Set COUNT1 value to 60)**
403 403  
404 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)**   (Set COUNT1 value to 60)**
405 -
406 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)**   (Set COUNT2 value to 60)**
412 +**AT+SETCNT=2,60   (Set COUNT2 value to 60)**
407 407  )))
414 +)))
408 408  
409 409  
410 410  
... ... @@ -496,19 +496,22 @@
496 496  
497 497  
498 498  **Plus below command for AVI1 Counting:**
506 +)))
499 499  
508 +(% class="box infomessage" %)
509 +(((
510 +(((
511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**   (set AVI Count to 60)**
500 500  
501 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**  (set AVI Count to 60)**
513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
502 502  
503 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**  (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
504 504  
505 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**  (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
506 -
507 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**  (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
508 508  )))
519 +)))
509 509  
510 510  
511 -
512 512  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
513 513  
514 514  
... ... @@ -725,19 +725,23 @@
725 725  
726 726  * (% style="color:#037691" %)**AT Command:**
727 727  
738 +(% class="box infomessage" %)
739 +(((
728 728  **AT+TDC=N **
741 +)))
729 729  
730 -
731 731  **Example: **AT+TDC=30000. Means set interval to 30 seconds
732 732  
733 733  
734 734  * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**
735 735  
748 +(% class="box infomessage" %)
749 +(((
736 736  **0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
751 +)))
737 737  
738 738  
739 739  
740 -
741 741  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
742 742  
743 743  Set work mode.
... ... @@ -744,29 +744,36 @@
744 744  
745 745  * (% style="color:#037691" %)**AT Command:**
746 746  
761 +(% class="box infomessage" %)
762 +(((
747 747  **AT+MOD=N  **
764 +)))
748 748  
749 -
750 750  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
751 751  
752 752  
753 753  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
754 754  
755 -**0x0A aa    ** ~/~/ Same as AT+MOD=aa
771 +(% class="box infomessage" %)
772 +(((
773 +**0x0A aa     ~/~/ Same as AT+MOD=aa**
774 +)))
756 756  
757 757  
758 758  
759 -
760 760  ==== 3.4.2.3 Poll an uplink ====
761 761  
762 -* (% style="color:#037691" %)**AT Command:**
780 +* (% style="color:#037691" %)AT Command:
763 763  
764 764  There is no AT Command to poll uplink
765 765  
766 766  
767 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**
785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08):
768 768  
769 -**0x08 FF     **~/~/ Poll an uplink
787 +(% class="box infomessage" %)
788 +(((
789 +**0x08 FF     ~/~/ Poll an uplink,**
790 +)))
770 770  
771 771  **Example**: 0x08FF, ask device to send an Uplink
772 772  
... ... @@ -776,9 +776,12 @@
776 776  
777 777  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
778 778  
779 -* (% style="color:#037691" %)**AT Command:**
800 +* (% style="color:#037691" %)AT Command:
780 780  
802 +(% class="box infomessage" %)
803 +(((
781 781  **AT+ADDMOD6=1 or 0**
805 +)))
782 782  
783 783  1: Enable Trigger Mode
784 784  
... ... @@ -785,36 +785,43 @@
785 785  0: Disable Trigger Mode
786 786  
787 787  
788 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**
812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06):
789 789  
790 -**0x0A 06 aa    ** ~/~/ Same as AT+ADDMOD6=aa
814 +(% class="box infomessage" %)
815 +(((
816 +**0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,**
817 +)))
791 791  
792 792  
793 793  
794 -
795 795  ==== 3.4.2.5 Poll trigger settings ====
796 796  
797 797  Poll trigger settings,
798 798  
799 -* (% style="color:#037691" %)**AT Command:**
825 +* (% style="color:#037691" %)AT Command:
800 800  
801 801  There is no AT Command for this feature.
802 802  
803 803  
804 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
805 805  
806 -**0xAB 06         **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
832 +(% class="box infomessage" %)
833 +(((
834 +**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
835 +)))
807 807  
808 808  
809 809  
810 -
811 811  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
812 812  
813 813  Enable Disable DI1/DI2/DI2 as trigger,
814 814  
815 -* (% style="color:#037691" %)**AT Command:**
843 +* (% style="color:#037691" %)AT Command:
816 816  
845 +(% class="box infomessage" %)
846 +(((
817 817  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
848 +)))
818 818  
819 819  
820 820  **Example:**
... ... @@ -821,18 +821,20 @@
821 821  
822 822  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
823 823  
824 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
825 825  
826 -**0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
857 +(% class="box infomessage" %)
858 +(((
859 +**0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb**
860 +)))
827 827  
828 828  
829 829  
830 -
831 831  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
832 832  
833 833  Set DI1 or DI3(for LT-33222-L) trigger.
834 834  
835 -* (% style="color:#037691" %)**AT Command:**
868 +* (% style="color:#037691" %)AT Command:
836 836  
837 837  **AT+TRIG1=a,b**
838 838  
... ... @@ -847,8 +847,11 @@
847 847  
848 848  
849 849  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
850 -* **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
883 +* **0x09 01 aa bb cc  ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
851 851  
885 +
886 +
887 +
852 852  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
853 853  
854 854  Set DI2 trigger.
... ... @@ -870,7 +870,7 @@
870 870  
871 871  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
872 872  
873 -**0x09 02 aa bb cc           **~/~/ same as AT+TRIG1=aa,0x(bb cc)
909 +**0x09 02 aa bb cc  **~/~/ same as AT+TRIG1=aa,0x(bb cc)
874 874  
875 875  
876 876  
... ... @@ -886,7 +886,7 @@
886 886  
887 887  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
888 888  
889 -**0x AA 01 aa bb cc dd ee ff gg hh        ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
925 +**0x AA 01 aa bb cc dd ee ff gg hh  ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
890 890  
891 891  
892 892  
... ... @@ -902,7 +902,7 @@
902 902  
903 903  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
904 904  
905 -**0x AA 00 aa bb cc dd ee ff gg hh    ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
941 +**0x AA 00 aa bb cc dd ee ff gg hh  ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
906 906  
907 907  
908 908  
... ... @@ -909,25 +909,20 @@
909 909  
910 910  ==== 3.4.2.11 Trigger – Set minimum interval ====
911 911  
912 -Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger.
948 +Set AV and AC trigger minimum interval, system wont response to the second trigger within this set time after the first trigger.
913 913  
914 914  * (% style="color:#037691" %)**AT Command**
915 915  
916 -**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
952 +**AT+ATDC=5. Device wont response the second trigger within 5 minute after the first trigger.**
917 917  
918 918  
919 919  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
920 920  
921 -**0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
957 +**0x AC aa bb  ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
922 922  
923 -(((
924 -
925 925  
926 -(% style="color:red" %)Note: ATDC setting must be more than 5min
927 -)))
928 928  
929 929  
930 -
931 931  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
932 932  
933 933  * (% style="color:#037691" %)**AT Command**
... ... @@ -938,6 +938,7 @@
938 938  * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
939 939  * **0x02 aa bb cc     **~/~/ Set DO1/DO2/DO3 output
940 940  
972 +
941 941  (((
942 942  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
943 943  )))
... ... @@ -1114,7 +1114,7 @@
1114 1114  
1115 1115  * (% style="color:#037691" %)**AT Command:**
1116 1116  
1117 -**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1149 +(% style="color:#037691" %)**​​​​​​​**(%%)**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1118 1118  
1119 1119  
1120 1120  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**
... ... @@ -1128,7 +1128,7 @@
1128 1128  
1129 1129  * (% style="color:#037691" %)**AT Command:**
1130 1130  
1131 -**AT+SETCNT=aa,(bb cc dd ee) **
1163 +(% style="color:#037691" %)**​​​​​​​​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1132 1132  
1133 1133  aa: 1: Set count1,
1134 1134  
... ... @@ -1152,7 +1152,7 @@
1152 1152  
1153 1153  * (% style="color:#037691" %)**AT Command:**
1154 1154  
1155 -**AT+CLRCOUNT ** ~/~/ clear all counting
1187 +(% style="color:#037691" %)​​​​​​​​​​​​​​(%%)**AT+CLRCOUNT ** ~/~/ clear all counting
1156 1156  
1157 1157  
1158 1158  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
... ... @@ -1410,7 +1410,6 @@
1410 1410  [[image:image-20220524100748-11.png]]
1411 1411  
1412 1412  
1413 -
1414 1414  = 4. Use AT Command =
1415 1415  
1416 1416  == 4.1 Access AT Command ==
... ... @@ -1613,6 +1613,8 @@
1613 1613  
1614 1614  (((
1615 1615  AT+CFG: Print all settings
1647 +
1648 +
1616 1616  )))
1617 1617  
1618 1618  
... ... @@ -1658,6 +1658,8 @@
1658 1658  
1659 1659  (((
1660 1660  (% style="background-color:#dcdcdc" %)ATZ
1694 +
1695 +
1661 1661  )))
1662 1662  
1663 1663  
... ... @@ -1864,8 +1864,6 @@
1864 1864  == 5.5 Can i use point to point communication for LT-22222-L? ==
1865 1865  
1866 1866  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1867 -
1868 -
1869 1869  )))
1870 1870  
1871 1871  (((
... ... @@ -1879,7 +1879,6 @@
1879 1879  
1880 1880  After restart, the status before power failure will be read from flash.
1881 1881  
1882 -
1883 1883  = 6. Trouble Shooting =
1884 1884  )))
1885 1885  
... ... @@ -1914,8 +1914,10 @@
1914 1914  )))
1915 1915  
1916 1916  
1949 +
1917 1917  = 7. Order Info =
1918 1918  
1952 +
1919 1919  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
1920 1920  
1921 1921  
... ... @@ -1955,10 +1955,6 @@
1955 1955  )))
1956 1956  * (((
1957 1957  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1958 -
1959 -
1960 -
1961 -
1962 1962  )))
1963 1963  
1964 1964  = 10. Reference​​​​​ =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0