Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -182,6 +182,7 @@ 182 182 * Counting 183 183 184 184 185 + 185 185 == 1.4 Applications == 186 186 187 187 * Smart Buildings & Home Automation ... ... @@ -192,6 +192,7 @@ 192 192 * Smart Factory 193 193 194 194 196 + 195 195 == 1.5 Hardware Variants == 196 196 197 197 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -205,6 +205,7 @@ 205 205 * 1 x Counting Port 206 206 ))) 207 207 210 + 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -391,20 +391,24 @@ 391 391 392 392 ((( 393 393 **For LT22222-L:** 397 +))) 394 394 399 +(% class="box infomessage" %) 400 +((( 401 +((( 402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 395 395 396 - (% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger onlowlevel, valid signal is 100ms) **404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 397 397 398 - (% style="color:blue" %)**AT+TRIG1=1,100**(%%)**1port to trigger onhighlevel, valid signal is 100ms406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 399 399 400 - (% style="color:blue" %)**AT+TRIG2=0,100**(%%)**lowlevel, valid signal is 100ms) **408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 401 401 402 - (% style="color:blue" %)**AT+TRIG2=1,100**(%%)**setDI2port to trigger on high level, validsignalis 100ms)410 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 403 403 404 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 405 - 406 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 412 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 407 407 ))) 414 +))) 408 408 409 409 410 410 ... ... @@ -496,19 +496,22 @@ 496 496 497 497 498 498 **Plus below command for AVI1 Counting:** 506 +))) 499 499 508 +(% class="box infomessage" %) 509 +((( 510 +((( 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 500 500 501 -(% style="color:blue" %)**AT+ SETCNT=3,60**(%%)**(set AVICountto60)**513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 502 502 503 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** higher than VOLMAX (20000mV =20v), counter increase 1)**515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 504 504 505 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 506 - 507 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 508 508 ))) 519 +))) 509 509 510 510 511 - 512 512 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 513 513 514 514 ... ... @@ -725,19 +725,23 @@ 725 725 726 726 * (% style="color:#037691" %)**AT Command:** 727 727 738 +(% class="box infomessage" %) 739 +((( 728 728 **AT+TDC=N ** 741 +))) 729 729 730 - 731 731 **Example: **AT+TDC=30000. Means set interval to 30 seconds 732 732 733 733 734 734 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 735 735 748 +(% class="box infomessage" %) 749 +((( 736 736 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 751 +))) 737 737 738 738 739 739 740 - 741 741 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 742 742 743 743 Set work mode. ... ... @@ -744,29 +744,36 @@ 744 744 745 745 * (% style="color:#037691" %)**AT Command:** 746 746 761 +(% class="box infomessage" %) 762 +((( 747 747 **AT+MOD=N ** 764 +))) 748 748 749 - 750 750 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 751 751 752 752 753 753 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 754 754 755 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 771 +(% class="box infomessage" %) 772 +((( 773 +**0x0A aa ~/~/ Same as AT+MOD=aa** 774 +))) 756 756 757 757 758 758 759 - 760 760 ==== 3.4.2.3 Poll an uplink ==== 761 761 762 -* (% style="color:#037691" %) **AT Command:**780 +* (% style="color:#037691" %)AT Command: 763 763 764 764 There is no AT Command to poll uplink 765 765 766 766 767 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x08):**785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 768 768 769 -**0x08 FF **~/~/ Poll an uplink 787 +(% class="box infomessage" %) 788 +((( 789 +**0x08 FF ~/~/ Poll an uplink,** 790 +))) 770 770 771 771 **Example**: 0x08FF, ask device to send an Uplink 772 772 ... ... @@ -776,9 +776,12 @@ 776 776 777 777 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 778 778 779 -* (% style="color:#037691" %) **AT Command:**800 +* (% style="color:#037691" %)AT Command: 780 780 802 +(% class="box infomessage" %) 803 +((( 781 781 **AT+ADDMOD6=1 or 0** 805 +))) 782 782 783 783 1: Enable Trigger Mode 784 784 ... ... @@ -785,36 +785,43 @@ 785 785 0: Disable Trigger Mode 786 786 787 787 788 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x0A 06):**812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 789 789 790 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 814 +(% class="box infomessage" %) 815 +((( 816 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 817 +))) 791 791 792 792 793 793 794 - 795 795 ==== 3.4.2.5 Poll trigger settings ==== 796 796 797 797 Poll trigger settings, 798 798 799 -* (% style="color:#037691" %) **AT Command:**825 +* (% style="color:#037691" %)AT Command: 800 800 801 801 There is no AT Command for this feature. 802 802 803 803 804 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 805 805 806 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 832 +(% class="box infomessage" %) 833 +((( 834 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 835 +))) 807 807 808 808 809 809 810 - 811 811 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 812 812 813 813 Enable Disable DI1/DI2/DI2 as trigger, 814 814 815 -* (% style="color:#037691" %) **AT Command:**843 +* (% style="color:#037691" %)AT Command: 816 816 845 +(% class="box infomessage" %) 846 +((( 817 817 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 +))) 818 818 819 819 820 820 **Example:** ... ... @@ -821,20 +821,25 @@ 821 821 822 822 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 823 823 824 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 825 825 826 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 857 +(% class="box infomessage" %) 858 +((( 859 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 +))) 827 827 828 828 829 829 830 - 831 831 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 832 832 833 833 Set DI1 or DI3(for LT-33222-L) trigger. 834 834 835 -* (% style="color:#037691" %) **AT Command:**868 +* (% style="color:#037691" %)AT Command: 836 836 870 +(% class="box infomessage" %) 871 +((( 837 837 **AT+TRIG1=a,b** 873 +))) 838 838 839 839 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 840 840 ... ... @@ -846,9 +846,15 @@ 846 846 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 847 847 848 848 849 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 850 -* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 851 851 887 +(% class="box infomessage" %) 888 +((( 889 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 +))) 891 + 892 + 893 + 852 852 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 853 853 854 854 Set DI2 trigger. ... ... @@ -870,7 +870,7 @@ 870 870 871 871 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 872 872 873 -**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc)915 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 874 874 875 875 876 876 ... ... @@ -886,7 +886,7 @@ 886 886 887 887 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 888 888 889 -**0x AA 01 aa bb cc dd ee ff gg hh 931 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 890 890 891 891 892 892 ... ... @@ -902,7 +902,7 @@ 902 902 903 903 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 904 904 905 -**0x AA 00 aa bb cc dd ee ff gg hh 947 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 906 906 907 907 908 908 ... ... @@ -909,25 +909,20 @@ 909 909 910 910 ==== 3.4.2.11 Trigger – Set minimum interval ==== 911 911 912 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.954 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 913 913 914 914 * (% style="color:#037691" %)**AT Command** 915 915 916 -**AT+ATDC=5 **Device won't response the second trigger within 5 minute after the first trigger.958 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 917 917 918 918 919 919 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 920 920 921 -**0x AC aa bb 963 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 922 922 923 -((( 924 - 925 925 926 -(% style="color:red" %)Note: ATDC setting must be more than 5min 927 -))) 928 928 929 929 930 - 931 931 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 932 932 933 933 * (% style="color:#037691" %)**AT Command** ... ... @@ -938,6 +938,7 @@ 938 938 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 939 939 * **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 940 940 978 + 941 941 ((( 942 942 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 943 943 ))) ... ... @@ -1114,7 +1114,7 @@ 1114 1114 1115 1115 * (% style="color:#037691" %)**AT Command:** 1116 1116 1117 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1155 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1118 1118 1119 1119 1120 1120 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1128,7 +1128,7 @@ 1128 1128 1129 1129 * (% style="color:#037691" %)**AT Command:** 1130 1130 1131 -**AT+SETCNT=aa,(bb cc dd ee) ** 1169 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1132 1132 1133 1133 aa: 1: Set count1, 1134 1134 ... ... @@ -1152,7 +1152,7 @@ 1152 1152 1153 1153 * (% style="color:#037691" %)**AT Command:** 1154 1154 1155 -**AT+CLRCOUNT ** ~/~/ clear all counting 1193 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1156 1156 1157 1157 1158 1158 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1410,7 +1410,6 @@ 1410 1410 [[image:image-20220524100748-11.png]] 1411 1411 1412 1412 1413 - 1414 1414 = 4. Use AT Command = 1415 1415 1416 1416 == 4.1 Access AT Command == ... ... @@ -1613,6 +1613,8 @@ 1613 1613 1614 1614 ((( 1615 1615 AT+CFG: Print all settings 1653 + 1654 + 1616 1616 ))) 1617 1617 1618 1618 ... ... @@ -1658,6 +1658,8 @@ 1658 1658 1659 1659 ((( 1660 1660 (% style="background-color:#dcdcdc" %)ATZ 1700 + 1701 + 1661 1661 ))) 1662 1662 1663 1663 ... ... @@ -1864,8 +1864,6 @@ 1864 1864 == 5.5 Can i use point to point communication for LT-22222-L? == 1865 1865 1866 1866 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1867 - 1868 - 1869 1869 ))) 1870 1870 1871 1871 ((( ... ... @@ -1879,7 +1879,6 @@ 1879 1879 1880 1880 After restart, the status before power failure will be read from flash. 1881 1881 1882 - 1883 1883 = 6. Trouble Shooting = 1884 1884 ))) 1885 1885 ... ... @@ -1914,8 +1914,10 @@ 1914 1914 ))) 1915 1915 1916 1916 1955 + 1917 1917 = 7. Order Info = 1918 1918 1958 + 1919 1919 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1920 1920 1921 1921 ... ... @@ -1955,10 +1955,6 @@ 1955 1955 ))) 1956 1956 * ((( 1957 1957 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1958 - 1959 - 1960 - 1961 - 1962 1962 ))) 1963 1963 1964 1964 = 10. Reference =