Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Bei1 +XWiki.Xiaoling - Content
-
... ... @@ -182,6 +182,7 @@ 182 182 * Counting 183 183 184 184 185 + 185 185 == 1.4 Applications == 186 186 187 187 * Smart Buildings & Home Automation ... ... @@ -192,6 +192,7 @@ 192 192 * Smart Factory 193 193 194 194 196 + 195 195 == 1.5 Hardware Variants == 196 196 197 197 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -205,6 +205,7 @@ 205 205 * 1 x Counting Port 206 206 ))) 207 207 210 + 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -391,20 +391,24 @@ 391 391 392 392 ((( 393 393 **For LT22222-L:** 397 +))) 394 394 399 +(% class="box infomessage" %) 400 +((( 401 +((( 402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 395 395 396 - (% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger onlowlevel, valid signal is 100ms) **404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 397 397 398 - (% style="color:blue" %)**AT+TRIG1=1,100**(%%)**1port to trigger onhighlevel, valid signal is 100ms406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 399 399 400 - (% style="color:blue" %)**AT+TRIG2=0,100**(%%)**lowlevel, valid signal is 100ms) **408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 401 401 402 - (% style="color:blue" %)**AT+TRIG2=1,100**(%%)**setDI2port to trigger on high level, validsignalis 100ms)410 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 403 403 404 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 405 - 406 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 412 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 407 407 ))) 414 +))) 408 408 409 409 410 410 ... ... @@ -496,19 +496,22 @@ 496 496 497 497 498 498 **Plus below command for AVI1 Counting:** 506 +))) 499 499 508 +(% class="box infomessage" %) 509 +((( 510 +((( 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 500 500 501 -(% style="color:blue" %)**AT+ SETCNT=3,60**(%%)**(set AVICountto60)**513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 502 502 503 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** higher than VOLMAX (20000mV =20v), counter increase 1)**515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 504 504 505 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 506 - 507 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 508 508 ))) 519 +))) 509 509 510 510 511 - 512 512 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 513 513 514 514 ... ... @@ -725,19 +725,23 @@ 725 725 726 726 * (% style="color:#037691" %)**AT Command:** 727 727 738 +(% class="box infomessage" %) 739 +((( 728 728 **AT+TDC=N ** 741 +))) 729 729 730 - 731 731 **Example: **AT+TDC=30000. Means set interval to 30 seconds 732 732 733 733 734 734 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 735 735 748 +(% class="box infomessage" %) 749 +((( 736 736 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 751 +))) 737 737 738 738 739 739 740 - 741 741 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 742 742 743 743 Set work mode. ... ... @@ -744,29 +744,36 @@ 744 744 745 745 * (% style="color:#037691" %)**AT Command:** 746 746 761 +(% class="box infomessage" %) 762 +((( 747 747 **AT+MOD=N ** 764 +))) 748 748 749 - 750 750 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 751 751 752 752 753 753 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 754 754 755 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 771 +(% class="box infomessage" %) 772 +((( 773 +**0x0A aa ~/~/ Same as AT+MOD=aa** 774 +))) 756 756 757 757 758 758 759 - 760 760 ==== 3.4.2.3 Poll an uplink ==== 761 761 762 -* (% style="color:#037691" %) **AT Command:**780 +* (% style="color:#037691" %)AT Command: 763 763 764 764 There is no AT Command to poll uplink 765 765 766 766 767 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x08):**785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 768 768 769 -**0x08 FF **~/~/ Poll an uplink 787 +(% class="box infomessage" %) 788 +((( 789 +**0x08 FF ~/~/ Poll an uplink,** 790 +))) 770 770 771 771 **Example**: 0x08FF, ask device to send an Uplink 772 772 ... ... @@ -776,9 +776,12 @@ 776 776 777 777 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 778 778 779 -* (% style="color:#037691" %) **AT Command:**800 +* (% style="color:#037691" %)AT Command: 780 780 802 +(% class="box infomessage" %) 803 +((( 781 781 **AT+ADDMOD6=1 or 0** 805 +))) 782 782 783 783 1: Enable Trigger Mode 784 784 ... ... @@ -785,36 +785,43 @@ 785 785 0: Disable Trigger Mode 786 786 787 787 788 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x0A 06):**812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 789 789 790 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 814 +(% class="box infomessage" %) 815 +((( 816 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 817 +))) 791 791 792 792 793 793 794 - 795 795 ==== 3.4.2.5 Poll trigger settings ==== 796 796 797 797 Poll trigger settings, 798 798 799 -* (% style="color:#037691" %) **AT Command:**825 +* (% style="color:#037691" %)AT Command: 800 800 801 801 There is no AT Command for this feature. 802 802 803 803 804 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 805 805 806 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 832 +(% class="box infomessage" %) 833 +((( 834 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 835 +))) 807 807 808 808 809 809 810 - 811 811 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 812 812 813 813 Enable Disable DI1/DI2/DI2 as trigger, 814 814 815 -* (% style="color:#037691" %) **AT Command:**843 +* (% style="color:#037691" %)AT Command: 816 816 845 +(% class="box infomessage" %) 846 +((( 817 817 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 +))) 818 818 819 819 820 820 **Example:** ... ... @@ -821,20 +821,25 @@ 821 821 822 822 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 823 823 824 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 825 825 826 -**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 857 +(% class="box infomessage" %) 858 +((( 859 +**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 860 +))) 827 827 828 828 829 829 830 - 831 831 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 832 832 833 833 Set DI1 or DI3(for LT-33222-L) trigger. 834 834 835 -* (% style="color:#037691" %) **AT Command:**868 +* (% style="color:#037691" %)AT Command: 836 836 870 +(% class="box infomessage" %) 871 +((( 837 837 **AT+TRIG1=a,b** 873 +))) 838 838 839 839 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 840 840 ... ... @@ -846,18 +846,26 @@ 846 846 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 847 847 848 848 849 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 850 -* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ): 851 851 887 +(% class="box infomessage" %) 888 +((( 889 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 890 +))) 891 + 892 + 893 + 852 852 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 853 853 854 854 Set DI2 trigger. 855 855 856 -* (% style="color:#037691" %) **AT Command:**898 +* (% style="color:#037691" %)AT Command: 857 857 900 +(% class="box infomessage" %) 901 +((( 858 858 **AT+TRIG2=a,b** 903 +))) 859 859 860 - 861 861 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 862 862 863 863 b : delay timing. ... ... @@ -868,62 +868,74 @@ 868 868 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 869 869 870 870 871 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x09 02 ):**915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ): 872 872 873 -**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 917 +(% class="box infomessage" %) 918 +((( 919 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 920 +))) 874 874 875 875 876 876 877 - 878 878 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 879 879 880 880 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 881 881 882 -* (% style="color:#037691" %) **AT Command**928 +* (% style="color:#037691" %)AT Command: 883 883 884 -**AT+ACLIM** 930 +(% class="box infomessage" %) 931 +((( 932 +**AT+ACLIM. ** 933 +))) 885 885 886 886 887 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 01 )**936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ): 888 888 889 -**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 938 +(% class="box infomessage" %) 939 +((( 940 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 941 +))) 890 890 891 891 892 892 893 - 894 894 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 895 895 896 896 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 897 897 898 -* (% style="color:#037691" %) **AT Command**949 +* (% style="color:#037691" %)AT Command: 899 899 900 -**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 951 +(% class="box infomessage" %) 952 +((( 953 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 954 +))) 901 901 902 902 903 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 00 )**957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ): 904 904 905 -**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 959 +(% class="box infomessage" %) 960 +((( 961 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 962 +))) 906 906 907 907 908 908 909 - 910 910 ==== 3.4.2.11 Trigger – Set minimum interval ==== 911 911 912 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.968 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 913 913 914 -* (% style="color:#037691" %) **AT Command**970 +* (% style="color:#037691" %)AT Command: 915 915 916 -**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 972 +(% class="box infomessage" %) 973 +((( 974 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 975 +))) 917 917 918 918 919 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAC )**978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ): 920 920 921 -**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 922 - 980 +(% class="box infomessage" %) 923 923 ((( 924 - 925 - 926 -(% style="color:red" %)Note: ATDC setting must be more than 5min 982 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 927 927 ))) 928 928 929 929 ... ... @@ -930,15 +930,19 @@ 930 930 931 931 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 932 932 933 -* (% style="color:#037691" %) **AT Command**989 +* (% style="color:#037691" %)AT Command: 934 934 935 935 There is no AT Command to control Digital Output 936 936 937 937 938 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 939 -* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02): 940 940 996 +(% class="box infomessage" %) 941 941 ((( 998 +**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 999 +))) 1000 + 1001 +((( 942 942 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 943 943 ))) 944 944 ... ... @@ -958,19 +958,22 @@ 958 958 959 959 960 960 961 - 962 962 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 963 963 964 -* (% style="color:#037691" %) **AT Command**1023 +* (% style="color:#037691" %)AT Command: 965 965 966 966 There is no AT Command to control Digital Output 967 967 968 968 969 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA9)**1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9): 970 970 971 -**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1030 +(% class="box infomessage" %) 1031 +((( 1032 +((( 1033 +**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1034 +))) 1035 +))) 972 972 973 - 974 974 This is to control the digital output time of DO pin. Include four bytes: 975 975 976 976 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1024,19 +1024,20 @@ 1024 1024 1025 1025 1026 1026 1027 - 1028 1028 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1029 1029 1030 -* (% style="color:#037691" %) **AT Command:**1092 +* (% style="color:#037691" %)AT Command: 1031 1031 1032 1032 There is no AT Command to control Relay Output 1033 1033 1034 1034 1035 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x03):**1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03): 1036 1036 1037 -**0x03 aa bb **~/~/ Set RO1/RO2 output 1099 +(% class="box infomessage" %) 1100 +((( 1101 +**0x03 aa bb ~/~/ Set RO1/RO2 output** 1102 +))) 1038 1038 1039 - 1040 1040 ((( 1041 1041 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1042 1042 ))) ... ... @@ -1053,19 +1053,20 @@ 1053 1053 1054 1054 1055 1055 1056 - 1057 1057 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1058 1058 1059 -* (% style="color:#037691" %) **AT Command:**1122 +* (% style="color:#037691" %)AT Command: 1060 1060 1061 1061 There is no AT Command to control Relay Output 1062 1062 1063 1063 1064 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x05):**1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05): 1065 1065 1066 -**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1129 +(% class="box infomessage" %) 1130 +((( 1131 +**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1132 +))) 1067 1067 1068 - 1069 1069 This is to control the relay output time of relay. Include four bytes: 1070 1070 1071 1071 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1107,28 +1107,35 @@ 1107 1107 1108 1108 1109 1109 1110 - 1111 1111 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1112 1112 1113 1113 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1114 1114 1115 -* (% style="color:#037691" %) **AT Command:**1179 +* (% style="color:#037691" %)AT Command: 1116 1116 1117 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1181 +(% class="box infomessage" %) 1182 +((( 1183 +**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1184 +))) 1118 1118 1119 1119 1120 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA5):**1187 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA5): 1121 1121 1122 -**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1189 +(% class="box infomessage" %) 1190 +((( 1191 +**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1192 +))) 1123 1123 1124 1124 1125 1125 1126 - 1127 1127 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1128 1128 1129 -* (% style="color:#037691" %) **AT Command:**1198 +* (% style="color:#037691" %)AT Command: 1130 1130 1200 +(% class="box infomessage" %) 1201 +((( 1131 1131 **AT+SETCNT=aa,(bb cc dd ee) ** 1203 +))) 1132 1132 1133 1133 aa: 1: Set count1, 1134 1134 ... ... @@ -1139,29 +1139,35 @@ 1139 1139 Bb cc dd ee: number to be set 1140 1140 1141 1141 1142 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xA8):**1214 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA8): 1143 1143 1144 -**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1216 +(% class="box infomessage" %) 1217 +((( 1218 +**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1219 +))) 1145 1145 1146 1146 1147 1147 1148 - 1149 1149 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1150 1150 1151 1151 Clear counting for counting mode 1152 1152 1153 -* (% style="color:#037691" %) **AT Command:**1227 +* (% style="color:#037691" %)AT Command: 1154 1154 1155 -**AT+CLRCOUNT ** ~/~/ clear all counting 1229 +(% class="box infomessage" %) 1230 +((( 1231 +**AT+CLRCOUNT ~/~/ clear all counting** 1232 +))) 1156 1156 1234 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA6): 1157 1157 1158 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1236 +(% class="box infomessage" %) 1237 +((( 1238 +**0x A6 01 ~/~/ clear all counting,** 1239 +))) 1159 1159 1160 -**0x A6 01 ** ~/~/ clear all counting 1161 1161 1162 1162 1163 - 1164 - 1165 1165 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1166 1166 1167 1167 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1180,7 +1180,6 @@ 1180 1180 ))) 1181 1181 1182 1182 1183 - 1184 1184 == 3.5 Integrate with Mydevice == 1185 1185 1186 1186 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: ... ... @@ -1410,7 +1410,6 @@ 1410 1410 [[image:image-20220524100748-11.png]] 1411 1411 1412 1412 1413 - 1414 1414 = 4. Use AT Command = 1415 1415 1416 1416 == 4.1 Access AT Command == ... ... @@ -1613,6 +1613,8 @@ 1613 1613 1614 1614 ((( 1615 1615 AT+CFG: Print all settings 1692 + 1693 + 1616 1616 ))) 1617 1617 1618 1618 ... ... @@ -1658,6 +1658,8 @@ 1658 1658 1659 1659 ((( 1660 1660 (% style="background-color:#dcdcdc" %)ATZ 1739 + 1740 + 1661 1661 ))) 1662 1662 1663 1663 ... ... @@ -1864,8 +1864,6 @@ 1864 1864 == 5.5 Can i use point to point communication for LT-22222-L? == 1865 1865 1866 1866 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1867 - 1868 - 1869 1869 ))) 1870 1870 1871 1871 ((( ... ... @@ -1879,7 +1879,6 @@ 1879 1879 1880 1880 After restart, the status before power failure will be read from flash. 1881 1881 1882 - 1883 1883 = 6. Trouble Shooting = 1884 1884 ))) 1885 1885 ... ... @@ -1914,8 +1914,10 @@ 1914 1914 ))) 1915 1915 1916 1916 1994 + 1917 1917 = 7. Order Info = 1918 1918 1997 + 1919 1919 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1920 1920 1921 1921 ... ... @@ -1955,10 +1955,6 @@ 1955 1955 ))) 1956 1956 * ((( 1957 1957 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1958 - 1959 - 1960 - 1961 - 1962 1962 ))) 1963 1963 1964 1964 = 10. Reference =