From version < 83.1 >
edited by Bei Jinggeng
on 2022/06/28 13:36
To version < 82.11 >
edited by Xiaoling
on 2022/06/20 11:43
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bei
1 +XWiki.Xiaoling
Content
... ... @@ -182,6 +182,7 @@
182 182  * Counting
183 183  
184 184  
185 +
185 185  == 1.4  Applications ==
186 186  
187 187  * Smart Buildings & Home Automation
... ... @@ -192,6 +192,7 @@
192 192  * Smart Factory
193 193  
194 194  
196 +
195 195  == 1.5 Hardware Variants ==
196 196  
197 197  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -205,6 +205,7 @@
205 205  * 1 x Counting Port
206 206  )))
207 207  
210 +
208 208  = 2. Power ON Device =
209 209  
210 210  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -391,20 +391,24 @@
391 391  
392 392  (((
393 393  **For LT22222-L:**
397 +)))
394 394  
399 +(% class="box infomessage" %)
400 +(((
401 +(((
402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) **
395 395  
396 -(% style="color:blue" %)**AT+TRIG1=0,100**(%%)**  (set DI1 port to trigger on low level, valid signal is 100ms) **
404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) **
397 397  
398 -(% style="color:blue" %)**AT+TRIG1=1,100**(%%)**  (set DI1 port to trigger on high level, valid signal is 100ms ) **
406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) **
399 399  
400 -(% style="color:blue" %)**AT+TRIG2=0,100**(%%)**  (set DI2 port to trigger on low level, valid signal is 100ms) **
408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) **
401 401  
402 -(% style="color:blue" %)**AT+TRIG2=1,100**(%%)**  (set DI2 port to trigger on high level, valid signal is 100ms ) **
410 +**AT+SETCNT=1,6  (Set COUNT1 value to 60)**
403 403  
404 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)**   (Set COUNT1 value to 60)**
405 -
406 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)**   (Set COUNT2 value to 60)**
412 +**AT+SETCNT=2,60   (Set COUNT2 value to 60)**
407 407  )))
414 +)))
408 408  
409 409  
410 410  
... ... @@ -496,19 +496,22 @@
496 496  
497 497  
498 498  **Plus below command for AVI1 Counting:**
506 +)))
499 499  
508 +(% class="box infomessage" %)
509 +(((
510 +(((
511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**   (set AVI Count to 60)**
500 500  
501 -(% style="color:blue" %)**AT+SETCNT=3,60**(%%)**  (set AVI Count to 60)**
513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**   (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
502 502  
503 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)**  (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)**
515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**   (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
504 504  
505 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)**  (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)**
506 -
507 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**  (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)**   (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)**
508 508  )))
519 +)))
509 509  
510 510  
511 -
512 512  === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI ===
513 513  
514 514  
... ... @@ -725,19 +725,23 @@
725 725  
726 726  * (% style="color:#037691" %)**AT Command:**
727 727  
738 +(% class="box infomessage" %)
739 +(((
728 728  **AT+TDC=N **
741 +)))
729 729  
730 -
731 731  **Example: **AT+TDC=30000. Means set interval to 30 seconds
732 732  
733 733  
734 734  * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):**
735 735  
748 +(% class="box infomessage" %)
749 +(((
736 736  **0x01 aa bb cc     ~/~/ Same as AT+TDC=0x(aa bb cc)**
751 +)))
737 737  
738 738  
739 739  
740 -
741 741  ==== 3.4.2.2 Set Work Mode (AT+MOD) ====
742 742  
743 743  Set work mode.
... ... @@ -744,29 +744,36 @@
744 744  
745 745  * (% style="color:#037691" %)**AT Command:**
746 746  
761 +(% class="box infomessage" %)
762 +(((
747 747  **AT+MOD=N  **
764 +)))
748 748  
749 -
750 750  **Example**: AT+MOD=2. Set work mode to Double DI counting mode
751 751  
752 752  
753 753  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
754 754  
755 -**0x0A aa    ** ~/~/ Same as AT+MOD=aa
771 +(% class="box infomessage" %)
772 +(((
773 +**0x0A aa     ~/~/ Same as AT+MOD=aa**
774 +)))
756 756  
757 757  
758 758  
759 -
760 760  ==== 3.4.2.3 Poll an uplink ====
761 761  
762 -* (% style="color:#037691" %)**AT Command:**
780 +* (% style="color:#037691" %)AT Command:
763 763  
764 764  There is no AT Command to poll uplink
765 765  
766 766  
767 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x08):**
785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08):
768 768  
769 -**0x08 FF     **~/~/ Poll an uplink
787 +(% class="box infomessage" %)
788 +(((
789 +**0x08 FF     ~/~/ Poll an uplink,**
790 +)))
770 770  
771 771  **Example**: 0x08FF, ask device to send an Uplink
772 772  
... ... @@ -776,9 +776,12 @@
776 776  
777 777  Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
778 778  
779 -* (% style="color:#037691" %)**AT Command:**
800 +* (% style="color:#037691" %)AT Command:
780 780  
802 +(% class="box infomessage" %)
803 +(((
781 781  **AT+ADDMOD6=1 or 0**
805 +)))
782 782  
783 783  1: Enable Trigger Mode
784 784  
... ... @@ -785,36 +785,43 @@
785 785  0: Disable Trigger Mode
786 786  
787 787  
788 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A 06):**
812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06):
789 789  
790 -**0x0A 06 aa    ** ~/~/ Same as AT+ADDMOD6=aa
814 +(% class="box infomessage" %)
815 +(((
816 +**0x0A 06 aa     ~/~/ Same as AT+ADDMOD6=aa,**
817 +)))
791 791  
792 792  
793 793  
794 -
795 795  ==== 3.4.2.5 Poll trigger settings ====
796 796  
797 797  Poll trigger settings,
798 798  
799 -* (% style="color:#037691" %)**AT Command:**
825 +* (% style="color:#037691" %)AT Command:
800 800  
801 801  There is no AT Command for this feature.
802 802  
803 803  
804 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
805 805  
806 -**0xAB 06         **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
832 +(% class="box infomessage" %)
833 +(((
834 +**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
835 +)))
807 807  
808 808  
809 809  
810 -
811 811  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
812 812  
813 813  Enable Disable DI1/DI2/DI2 as trigger,
814 814  
815 -* (% style="color:#037691" %)**AT Command:**
843 +* (% style="color:#037691" %)AT Command:
816 816  
845 +(% class="box infomessage" %)
846 +(((
817 817  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
848 +)))
818 818  
819 819  
820 820  **Example:**
... ... @@ -821,20 +821,25 @@
821 821  
822 822  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
823 823  
824 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
825 825  
826 -**0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
857 +(% class="box infomessage" %)
858 +(((
859 +**0xAA 02 aa bb  ~/~/ Same as AT+DTRI=aa,bb**
860 +)))
827 827  
828 828  
829 829  
830 -
831 831  ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ====
832 832  
833 833  Set DI1 or DI3(for LT-33222-L) trigger.
834 834  
835 -* (% style="color:#037691" %)**AT Command:**
868 +* (% style="color:#037691" %)AT Command:
836 836  
870 +(% class="box infomessage" %)
871 +(((
837 837  **AT+TRIG1=a,b**
873 +)))
838 838  
839 839  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
840 840  
... ... @@ -846,18 +846,26 @@
846 846  AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms )
847 847  
848 848  
849 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
850 -* **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
885 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 01 ):
851 851  
887 +(% class="box infomessage" %)
888 +(((
889 +**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
890 +)))
891 +
892 +
893 +
852 852  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
853 853  
854 854  Set DI2 trigger.
855 855  
856 -* (% style="color:#037691" %)**AT Command:**
898 +* (% style="color:#037691" %)AT Command:
857 857  
900 +(% class="box infomessage" %)
901 +(((
858 858  **AT+TRIG2=a,b**
903 +)))
859 859  
860 -
861 861  a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1).
862 862  
863 863  b : delay timing.
... ... @@ -868,62 +868,74 @@
868 868  AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms )
869 869  
870 870  
871 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):**
915 +* (% style="color:#037691" %)Downlink Payload (prefix 0x09 02 ):
872 872  
873 -**0x09 02 aa bb cc           **~/~/ same as AT+TRIG1=aa,0x(bb cc)
917 +(% class="box infomessage" %)
918 +(((
919 +**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)**
920 +)))
874 874  
875 875  
876 876  
877 -
878 878  ==== 3.4.2.9 Trigger – Set AC (current) as trigger ====
879 879  
880 880  Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
881 881  
882 -* (% style="color:#037691" %)**AT Command**
928 +* (% style="color:#037691" %)AT Command:
883 883  
884 -**AT+ACLIM**
930 +(% class="box infomessage" %)
931 +(((
932 +**AT+ACLIM. **
933 +)))
885 885  
886 886  
887 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )**
936 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 01 ):
888 888  
889 -**0x AA 01 aa bb cc dd ee ff gg hh        ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
938 +(% class="box infomessage" %)
939 +(((
940 +**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
941 +)))
890 890  
891 891  
892 892  
893 -
894 894  ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ====
895 895  
896 896  Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
897 897  
898 -* (% style="color:#037691" %)**AT Command**
949 +* (% style="color:#037691" %)AT Command:
899 899  
900 -**AT+AVLIM  See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
951 +(% class="box infomessage" %)
952 +(((
953 +**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]**
954 +)))
901 901  
902 902  
903 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )**
957 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 00 ):
904 904  
905 -**0x AA 00 aa bb cc dd ee ff gg hh    ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]
959 +(% class="box infomessage" %)
960 +(((
961 +**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] **
962 +)))
906 906  
907 907  
908 908  
909 -
910 910  ==== 3.4.2.11 Trigger – Set minimum interval ====
911 911  
912 -Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger.
968 +Set AV and AC trigger minimum interval, system wont response to the second trigger within this set time after the first trigger.
913 913  
914 -* (% style="color:#037691" %)**AT Command**
970 +* (% style="color:#037691" %)AT Command:
915 915  
916 -**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
972 +(% class="box infomessage" %)
973 +(((
974 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.**
975 +)))
917 917  
918 918  
919 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
978 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAC ):
920 920  
921 -**0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
922 -
980 +(% class="box infomessage" %)
923 923  (((
924 -
925 -
926 -(% style="color:red" %)Note: ATDC setting must be more than 5min
982 +**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)**
927 927  )))
928 928  
929 929  
... ... @@ -930,15 +930,19 @@
930 930  
931 931  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
932 932  
933 -* (% style="color:#037691" %)**AT Command**
989 +* (% style="color:#037691" %)AT Command:
934 934  
935 935  There is no AT Command to control Digital Output
936 936  
937 937  
938 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)**
939 -* **0x02 aa bb cc     **~/~/ Set DO1/DO2/DO3 output
994 +* (% style="color:#037691" %)Downlink Payload (prefix 0x02):
940 940  
996 +(% class="box infomessage" %)
941 941  (((
998 +**0x02 aa bb cc     ~/~/ Set DO1/DO2/DO3 output**
999 +)))
1000 +
1001 +(((
942 942  If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low.
943 943  )))
944 944  
... ... @@ -958,19 +958,22 @@
958 958  
959 959  
960 960  
961 -
962 962  ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ====
963 963  
964 -* (% style="color:#037691" %)**AT Command**
1023 +* (% style="color:#037691" %)AT Command:
965 965  
966 966  There is no AT Command to control Digital Output
967 967  
968 968  
969 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)**
1028 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA9):
970 970  
971 -**0xA9 aa bb cc     **~/~/ Set DO1/DO2/DO3 output with time control
1030 +(% class="box infomessage" %)
1031 +(((
1032 +(((
1033 +**0xA9 aa bb cc     ~/~/ Set DO1/DO2/DO3 output with time control**
1034 +)))
1035 +)))
972 972  
973 -
974 974  This is to control the digital output time of DO pin. Include four bytes:
975 975  
976 976  (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9)
... ... @@ -1024,19 +1024,20 @@
1024 1024  
1025 1025  
1026 1026  
1027 -
1028 1028  ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ====
1029 1029  
1030 -* (% style="color:#037691" %)**AT Command:**
1092 +* (% style="color:#037691" %)AT Command:
1031 1031  
1032 1032  There is no AT Command to control Relay Output
1033 1033  
1034 1034  
1035 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):**
1097 +* (% style="color:#037691" %)Downlink Payload (prefix 0x03):
1036 1036  
1037 -**0x03 aa bb     **~/~/ Set RO1/RO2 output
1099 +(% class="box infomessage" %)
1100 +(((
1101 +**0x03 aa bb     ~/~/ Set RO1/RO2 output**
1102 +)))
1038 1038  
1039 -
1040 1040  (((
1041 1041  If payload = 0x030100, it means set RO1 to close and RO2 to open.
1042 1042  )))
... ... @@ -1053,19 +1053,20 @@
1053 1053  
1054 1054  
1055 1055  
1056 -
1057 1057  ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ====
1058 1058  
1059 -* (% style="color:#037691" %)**AT Command:**
1122 +* (% style="color:#037691" %)AT Command:
1060 1060  
1061 1061  There is no AT Command to control Relay Output
1062 1062  
1063 1063  
1064 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):**
1127 +* (% style="color:#037691" %)Downlink Payload (prefix 0x05):
1065 1065  
1066 -**0x05 aa bb cc dd     **~/~/ Set RO1/RO2 relay with time control
1129 +(% class="box infomessage" %)
1130 +(((
1131 +**0x05 aa bb cc dd     ~/~/ Set RO1/RO2 relay with time control:**
1132 +)))
1067 1067  
1068 -
1069 1069  This is to control the relay output time of relay. Include four bytes:
1070 1070  
1071 1071  (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05)
... ... @@ -1107,28 +1107,35 @@
1107 1107  
1108 1108  
1109 1109  
1110 -
1111 1111  ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ====
1112 1112  
1113 1113  When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1114 1114  
1115 -* (% style="color:#037691" %)**AT Command:**
1179 +* (% style="color:#037691" %)AT Command:
1116 1116  
1117 -**AT+VOLMAX   ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]
1181 +(% class="box infomessage" %)
1182 +(((
1183 +**AT+VOLMAX    ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]**
1184 +)))
1118 1118  
1119 1119  
1120 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):**
1187 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA5):
1121 1121  
1122 -**0xA5 aa bb cc   **~/~/ Same as AT+VOLMAX=(aa bb),cc
1189 +(% class="box infomessage" %)
1190 +(((
1191 +**0xA5 aa bb cc   ~/~/ Same as AT+VOLMAX=(aa bb),cc**
1192 +)))
1123 1123  
1124 1124  
1125 1125  
1126 -
1127 1127  ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ====
1128 1128  
1129 -* (% style="color:#037691" %)**AT Command:**
1198 +* (% style="color:#037691" %)AT Command:
1130 1130  
1200 +(% class="box infomessage" %)
1201 +(((
1131 1131  **AT+SETCNT=aa,(bb cc dd ee) **
1203 +)))
1132 1132  
1133 1133  aa: 1: Set count1,
1134 1134  
... ... @@ -1139,29 +1139,35 @@
1139 1139  Bb cc dd ee: number to be set
1140 1140  
1141 1141  
1142 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):**
1214 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA8):
1143 1143  
1144 -**0x A8 aa bb cc dd ee     **~/~/ same as AT+SETCNT=aa,(bb cc dd ee)
1216 +(% class="box infomessage" %)
1217 +(((
1218 +**0x A8 aa bb cc dd ee     ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)**
1219 +)))
1145 1145  
1146 1146  
1147 1147  
1148 -
1149 1149  ==== 3.4.2.18 Counting ~-~- Clear Counting ====
1150 1150  
1151 1151  Clear counting for counting mode
1152 1152  
1153 -* (% style="color:#037691" %)**AT Command:**
1227 +* (% style="color:#037691" %)AT Command:
1154 1154  
1155 -**AT+CLRCOUNT ** ~/~/ clear all counting
1229 +(% class="box infomessage" %)
1230 +(((
1231 +**AT+CLRCOUNT ~/~/ clear all counting**
1232 +)))
1156 1156  
1234 +* (% style="color:#037691" %)Downlink Payload (prefix 0xA6):
1157 1157  
1158 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
1236 +(% class="box infomessage" %)
1237 +(((
1238 +**0x A6 01     ~/~/ clear all counting,**
1239 +)))
1159 1159  
1160 -**0x A6 01    ** ~/~/ clear all counting
1161 1161  
1162 1162  
1163 -
1164 -
1165 1165  ==== 3.4.2.19 Counting ~-~- Change counting mode save time ====
1166 1166  
1167 1167  * (% style="color:#037691" %)**AT Command:**
... ... @@ -1180,7 +1180,6 @@
1180 1180  )))
1181 1181  
1182 1182  
1183 -
1184 1184  == 3.5 Integrate with Mydevice ==
1185 1185  
1186 1186  Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps:
... ... @@ -1410,7 +1410,6 @@
1410 1410  [[image:image-20220524100748-11.png]]
1411 1411  
1412 1412  
1413 -
1414 1414  = 4. Use AT Command =
1415 1415  
1416 1416  == 4.1 Access AT Command ==
... ... @@ -1613,6 +1613,8 @@
1613 1613  
1614 1614  (((
1615 1615  AT+CFG: Print all settings
1692 +
1693 +
1616 1616  )))
1617 1617  
1618 1618  
... ... @@ -1658,6 +1658,8 @@
1658 1658  
1659 1659  (((
1660 1660  (% style="background-color:#dcdcdc" %)ATZ
1739 +
1740 +
1661 1661  )))
1662 1662  
1663 1663  
... ... @@ -1864,8 +1864,6 @@
1864 1864  == 5.5 Can i use point to point communication for LT-22222-L? ==
1865 1865  
1866 1866  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1867 -
1868 -
1869 1869  )))
1870 1870  
1871 1871  (((
... ... @@ -1879,7 +1879,6 @@
1879 1879  
1880 1880  After restart, the status before power failure will be read from flash.
1881 1881  
1882 -
1883 1883  = 6. Trouble Shooting =
1884 1884  )))
1885 1885  
... ... @@ -1914,8 +1914,10 @@
1914 1914  )))
1915 1915  
1916 1916  
1994 +
1917 1917  = 7. Order Info =
1918 1918  
1997 +
1919 1919  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
1920 1920  
1921 1921  
... ... @@ -1955,10 +1955,6 @@
1955 1955  )))
1956 1956  * (((
1957 1957  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1958 -
1959 -
1960 -
1961 -
1962 1962  )))
1963 1963  
1964 1964  = 10. Reference​​​​​ =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0