Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -183,7 +183,6 @@ 183 183 184 184 185 185 186 - 187 187 == 1.4 Applications == 188 188 189 189 * Smart Buildings & Home Automation ... ... @@ -195,7 +195,6 @@ 195 195 196 196 197 197 198 - 199 199 == 1.5 Hardware Variants == 200 200 201 201 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -210,7 +210,6 @@ 210 210 ))) 211 211 212 212 213 - 214 214 = 2. Power ON Device = 215 215 216 216 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -293,7 +293,6 @@ 293 293 294 294 295 295 296 - 297 297 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 298 298 299 299 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -332,7 +332,6 @@ 332 332 * [1] RO1 relay channel is close and the RO1 LED is ON. 333 333 * [0] RO2 relay channel is open and RO2 LED is OFF; 334 334 335 - 336 336 **LT22222-L:** 337 337 338 338 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -350,7 +350,6 @@ 350 350 351 351 352 352 353 - 354 354 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 355 355 356 356 ... ... @@ -387,12 +387,7 @@ 387 387 ((( 388 388 ((( 389 389 **AT+MOD=2** 390 -))) 391 -))) 392 392 393 -(% class="box infomessage" %) 394 -((( 395 -((( 396 396 **ATZ** 397 397 ))) 398 398 ))) ... ... @@ -411,40 +411,15 @@ 411 411 ((( 412 412 ((( 413 413 **AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 414 -))) 415 -))) 416 416 417 -(% class="box infomessage" %) 418 -((( 419 -((( 420 420 **AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 421 -))) 422 -))) 423 423 424 -(% class="box infomessage" %) 425 -((( 426 -((( 427 427 **AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 428 -))) 429 -))) 430 430 431 -(% class="box infomessage" %) 432 -((( 433 -((( 434 434 **AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 435 -))) 436 -))) 437 437 438 -(% class="box infomessage" %) 439 -((( 440 -((( 441 441 **AT+SETCNT=1,60 (Set COUNT1 value to 60)** 442 -))) 443 -))) 444 444 445 -(% class="box infomessage" %) 446 -((( 447 -((( 448 448 **AT+SETCNT=2,60 (Set COUNT2 value to 60)** 449 449 ))) 450 450 ))) ... ... @@ -479,12 +479,7 @@ 479 479 ((( 480 480 ((( 481 481 **AT+MOD=3** 482 -))) 483 -))) 484 484 485 -(% class="box infomessage" %) 486 -((( 487 -((( 488 488 **ATZ** 489 489 ))) 490 490 ))) ... ... @@ -529,20 +529,13 @@ 529 529 ((( 530 530 ((( 531 531 **AT+MOD=4** 532 -))) 533 -))) 534 534 535 -(% class="box infomessage" %) 536 -((( 537 -((( 538 538 **ATZ** 539 539 ))) 540 540 ))) 541 541 542 -((( 543 - 544 -))) 545 545 497 + 546 546 ((( 547 547 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 548 548 ))) ... ... @@ -556,33 +556,17 @@ 556 556 (% class="box infomessage" %) 557 557 ((( 558 558 ((( 559 -**AT+SETCNT=3,60 (set AVI Count to 60)** 560 -))) 561 -))) 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 562 562 563 -(% class="box infomessage" %) 564 -((( 565 -((( 566 -**AT+VOLMAX=20000 (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 567 -))) 568 -))) 513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 569 569 570 -(% class="box infomessage" %) 571 -((( 572 -((( 573 -**AT+VOLMAX=20000,0 (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 574 -))) 575 -))) 515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 576 576 577 -(% class="box infomessage" %) 578 -((( 579 -((( 580 -**AT+VOLMAX=20000,1 (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 581 581 ))) 582 582 ))) 583 583 584 584 585 - 586 586 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 587 587 588 588 ... ... @@ -616,12 +616,7 @@ 616 616 ((( 617 617 ((( 618 618 **AT+MOD=5** 619 -))) 620 -))) 621 621 622 -(% class="box infomessage" %) 623 -((( 624 -((( 625 625 **ATZ** 626 626 ))) 627 627 ))) ... ... @@ -647,7 +647,7 @@ 647 647 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 648 648 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 649 649 650 -**AT Command to set Trigger Condition**: 581 +(% style="color:#037691" %)**AT Command to set Trigger Condition**: 651 651 652 652 (% style="color:#4f81bd" %)**Trigger base on voltage**: 653 653 ... ... @@ -683,7 +683,7 @@ 683 683 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 684 684 685 685 686 -**Downlink Command to set Trigger Condition:** 617 +(% style="color:#037691" %)**Downlink Command to set Trigger Condition:** 687 687 688 688 Type Code: 0xAA. Downlink command same as AT Command **AT+AVLIM, AT+ACLIM** 689 689 ... ... @@ -788,6 +788,8 @@ 788 788 789 789 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 790 790 722 + 723 + 791 791 === 3.4.1 Common Commands === 792 792 793 793 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -800,7 +800,7 @@ 800 800 801 801 Set device uplink interval. 802 802 803 -* AT Command: 736 +* (% style="color:#037691" %)**AT Command:** 804 804 805 805 (% class="box infomessage" %) 806 806 ((( ... ... @@ -810,7 +810,7 @@ 810 810 **Example: **AT+TDC=30000. Means set interval to 30 seconds 811 811 812 812 813 -* Downlink Payload (prefix 0x01): 746 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 814 814 815 815 (% class="box infomessage" %) 816 816 ((( ... ... @@ -823,7 +823,7 @@ 823 823 824 824 Set work mode. 825 825 826 -* AT Command: 759 +* (% style="color:#037691" %)**AT Command:** 827 827 828 828 (% class="box infomessage" %) 829 829 ((( ... ... @@ -833,7 +833,7 @@ 833 833 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 834 834 835 835 836 -* Downlink Payload (prefix 0x0A): 769 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 837 837 838 838 (% class="box infomessage" %) 839 839 ((( ... ... @@ -844,12 +844,12 @@ 844 844 845 845 ==== 3.4.2.3 Poll an uplink ==== 846 846 847 -* AT Command: 780 +* (% style="color:#037691" %)AT Command: 848 848 849 849 There is no AT Command to poll uplink 850 850 851 851 852 -* Downlink Payload (prefix 0x08): 785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 853 853 854 854 (% class="box infomessage" %) 855 855 ((( ... ... @@ -864,7 +864,7 @@ 864 864 865 865 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 866 866 867 -* AT Command: 800 +* (% style="color:#037691" %)AT Command: 868 868 869 869 (% class="box infomessage" %) 870 870 ((( ... ... @@ -876,7 +876,7 @@ 876 876 0: Disable Trigger Mode 877 877 878 878 879 -* Downlink Payload (prefix 0x0A 06): 812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 880 880 881 881 (% class="box infomessage" %) 882 882 ((( ... ... @@ -889,12 +889,12 @@ 889 889 890 890 Poll trigger settings, 891 891 892 -* AT Command: 825 +* (% style="color:#037691" %)AT Command: 893 893 894 894 There is no AT Command for this feature. 895 895 896 896 897 -* Downlink Payload (prefix 0x AB 06): 830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 898 898 899 899 (% class="box infomessage" %) 900 900 ((( ... ... @@ -907,7 +907,7 @@ 907 907 908 908 Enable Disable DI1/DI2/DI2 as trigger, 909 909 910 -* AT Command: 843 +* (% style="color:#037691" %)AT Command: 911 911 912 912 (% class="box infomessage" %) 913 913 ((( ... ... @@ -919,25 +919,20 @@ 919 919 920 920 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 921 921 922 -* Downlink Payload (prefix 0xAA 02): 855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 923 923 924 -(% class="box infomessage" %) 925 -((( 926 -**0xAA 02 aa bb ~/~/ Same as AT+DTRI=aa,bb** 927 -))) 857 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 928 928 929 929 930 930 861 + 931 931 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 932 932 933 933 Set DI1 or DI3(for LT-33222-L) trigger. 934 934 935 -* AT Command: 866 +* (% style="color:#037691" %)AT Command: 936 936 937 -(% class="box infomessage" %) 938 -((( 939 939 **AT+TRIG1=a,b** 940 -))) 941 941 942 942 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 943 943 ... ... @@ -949,12 +949,9 @@ 949 949 AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) 950 950 951 951 952 -* Downlink Payload (prefix 0x09 01 ): 880 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 881 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 953 953 954 -(% class="box infomessage" %) 955 -((( 956 -**0x09 01 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 957 -))) 958 958 959 959 960 960 ... ... @@ -962,13 +962,11 @@ 962 962 963 963 Set DI2 trigger. 964 964 965 -* AT Command: 890 +* (% style="color:#037691" %)**AT Command:** 966 966 967 -(% class="box infomessage" %) 968 -((( 969 969 **AT+TRIG2=a,b** 970 -))) 971 971 894 + 972 972 a : Interrupt mode. 0: falling edge; 1: rising edge, 2: falling and raising edge(for MOD=1). 973 973 974 974 b : delay timing. ... ... @@ -979,91 +979,71 @@ 979 979 AT+TRIG2=0,100(set DI1 port to trigger on low level, valid signal is 100ms ) 980 980 981 981 982 -* Downlink Payload (prefix 0x09 02 ): 905 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 983 983 984 -(% class="box infomessage" %) 985 -((( 986 -**0x09 02 aa bb cc ~/~/ same as AT+TRIG1=aa,0x(bb cc)** 987 -))) 907 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 988 988 989 989 990 990 911 + 991 991 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 992 992 993 993 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 994 994 995 -* AT Command :916 +* (% style="color:#037691" %)**AT Command** 996 996 997 -(% class="box infomessage" %) 998 -((( 999 -**AT+ACLIM. ** 1000 -))) 918 +**AT+ACLIM** 1001 1001 1002 1002 1003 -* Downlink Payload (prefix 0xAA 01 ) :921 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 1004 1004 1005 -(% class="box infomessage" %) 1006 -((( 1007 -**0x AA 01 aa bb cc dd ee ff gg hh ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1008 -))) 923 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1009 1009 1010 1010 1011 1011 927 + 1012 1012 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 1013 1013 1014 1014 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1015 1015 1016 -* AT Command :932 +* (% style="color:#037691" %)**AT Command** 1017 1017 1018 -(% class="box infomessage" %) 1019 -((( 1020 -**AT+AVLIM. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1021 -))) 934 +**AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]]** 1022 1022 1023 1023 1024 -* Downlink Payload (prefix 0xAA 00 ) :937 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 1025 1025 1026 -(% class="box infomessage" %) 1027 -((( 1028 -**0x AA 00 aa bb cc dd ee ff gg hh ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] ** 1029 -))) 939 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 1030 1030 1031 1031 1032 1032 943 + 1033 1033 ==== 3.4.2.11 Trigger – Set minimum interval ==== 1034 1034 1035 1035 Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 1036 1036 1037 -* AT Command :948 +* (% style="color:#037691" %)**AT Command** 1038 1038 1039 -(% class="box infomessage" %) 1040 -((( 1041 1041 **AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 1042 -))) 1043 1043 1044 1044 1045 -* Downlink Payload (prefix 0xAC ) :953 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 1046 1046 1047 -(% class="box infomessage" %) 1048 -((( 1049 -**0x AC aa bb ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min)** 1050 -))) 955 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 1051 1051 1052 1052 1053 1053 959 + 1054 1054 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 1055 1055 1056 -* AT Command :962 +* (% style="color:#037691" %)**AT Command** 1057 1057 1058 1058 There is no AT Command to control Digital Output 1059 1059 1060 1060 1061 -* Downlink Payload (prefix 0x02): 967 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 968 +* **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 1062 1062 1063 -(% class="box infomessage" %) 1064 -((( 1065 -**0x02 aa bb cc ~/~/ Set DO1/DO2/DO3 output** 1066 -))) 1067 1067 1068 1068 ((( 1069 1069 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. ... ... @@ -1085,22 +1085,19 @@ 1085 1085 1086 1086 1087 1087 991 + 1088 1088 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 1089 1089 1090 -* AT Command :994 +* (% style="color:#037691" %)**AT Command** 1091 1091 1092 1092 There is no AT Command to control Digital Output 1093 1093 1094 1094 1095 -* Downlink Payload (prefix 0xA9) :999 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA9)** 1096 1096 1097 -(% class="box infomessage" %) 1098 -((( 1099 -((( 1100 -**0xA9 aa bb cc ~/~/ Set DO1/DO2/DO3 output with time control** 1101 -))) 1102 -))) 1001 +**0xA9 aa bb cc **~/~/ Set DO1/DO2/DO3 output with time control 1103 1103 1003 + 1104 1104 This is to control the digital output time of DO pin. Include four bytes: 1105 1105 1106 1106 (% style="color:#4f81bd" %)**First Byte**(%%)**:** Type code (0xA9) ... ... @@ -1154,20 +1154,19 @@ 1154 1154 1155 1155 1156 1156 1057 + 1157 1157 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1158 1158 1159 -* AT Command: 1060 +* (% style="color:#037691" %)**AT Command:** 1160 1160 1161 1161 There is no AT Command to control Relay Output 1162 1162 1163 1163 1164 -* Downlink Payload (prefix 0x03): 1065 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x03):** 1165 1165 1166 -(% class="box infomessage" %) 1167 -((( 1168 -**0x03 aa bb ~/~/ Set RO1/RO2 output** 1169 -))) 1067 +**0x03 aa bb **~/~/ Set RO1/RO2 output 1170 1170 1069 + 1171 1171 ((( 1172 1172 If payload = 0x030100, it means set RO1 to close and RO2 to open. 1173 1173 ))) ... ... @@ -1184,20 +1184,19 @@ 1184 1184 1185 1185 1186 1186 1086 + 1187 1187 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1188 1188 1189 -* AT Command: 1089 +* (% style="color:#037691" %)**AT Command:** 1190 1190 1191 1191 There is no AT Command to control Relay Output 1192 1192 1193 1193 1194 -* Downlink Payload (prefix 0x05): 1094 +* (% style="color:#037691" %)**Downlink Payload (prefix 0x05):** 1195 1195 1196 -(% class="box infomessage" %) 1197 -((( 1198 -**0x05 aa bb cc dd ~/~/ Set RO1/RO2 relay with time control:** 1199 -))) 1096 +**0x05 aa bb cc dd **~/~/ Set RO1/RO2 relay with time control 1200 1200 1098 + 1201 1201 This is to control the relay output time of relay. Include four bytes: 1202 1202 1203 1203 (% style="color:#4f81bd" %)**First Byte **(%%)**:** Type code (0x05) ... ... @@ -1239,35 +1239,28 @@ 1239 1239 1240 1240 1241 1241 1140 + 1242 1242 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1243 1243 1244 1244 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1245 1245 1246 -* AT Command: 1145 +* (% style="color:#037691" %)**AT Command:** 1247 1247 1248 -(% class="box infomessage" %) 1249 -((( 1250 -**AT+VOLMAX ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]]** 1251 -))) 1147 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1252 1252 1253 1253 1254 -* Downlink Payload (prefix 0xA5): 1150 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** 1255 1255 1256 -(% class="box infomessage" %) 1257 -((( 1258 -**0xA5 aa bb cc ~/~/ Same as AT+VOLMAX=(aa bb),cc** 1259 -))) 1152 +**0xA5 aa bb cc **~/~/ Same as AT+VOLMAX=(aa bb),cc 1260 1260 1261 1261 1262 1262 1156 + 1263 1263 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1264 1264 1265 -* AT Command: 1159 +* (% style="color:#037691" %)**AT Command:** 1266 1266 1267 -(% class="box infomessage" %) 1268 -((( 1269 -**AT+SETCNT=aa,(bb cc dd ee) ** 1270 -))) 1161 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1271 1271 1272 1272 aa: 1: Set count1, 1273 1273 ... ... @@ -1278,51 +1278,40 @@ 1278 1278 Bb cc dd ee: number to be set 1279 1279 1280 1280 1281 -* Downlink Payload (prefix 0xA8): 1172 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA8):** 1282 1282 1283 -(% class="box infomessage" %) 1284 -((( 1285 -**0x A8 aa bb cc dd ee ~/~/ same as AT+SETCNT=aa,(bb cc dd ee)** 1286 -))) 1174 +**0x A8 aa bb cc dd ee **~/~/ same as AT+SETCNT=aa,(bb cc dd ee) 1287 1287 1288 1288 1289 1289 1178 + 1290 1290 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1291 1291 1292 1292 Clear counting for counting mode 1293 1293 1294 -* AT Command: 1183 +* (% style="color:#037691" %)**AT Command:** 1295 1295 1296 -(% class="box infomessage" %) 1297 -((( 1298 -**AT+CLRCOUNT ~/~/ clear all counting** 1299 -))) 1185 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1300 1300 1301 -* Downlink Payload (prefix 0xA6): 1302 1302 1303 -(% class="box infomessage" %) 1304 -((( 1305 -**0x A6 01 ~/~/ clear all counting,** 1306 -))) 1188 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** 1307 1307 1190 +**0x A6 01 ** ~/~/ clear all counting 1308 1308 1309 1309 1193 + 1194 + 1310 1310 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1311 1311 1312 -* AT Command: 1197 +* (% style="color:#037691" %)**AT Command:** 1313 1313 1314 -(% class="box infomessage" %) 1315 -((( 1316 -**AT+COUTIME=60 ~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30)** 1317 -))) 1199 +**AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) 1318 1318 1319 -* Downlink Payload (prefix 0xA7): 1320 1320 1321 -(% class="box infomessage" %) 1322 -((( 1323 -**0x A7 aa bb cc ~/~/ same as AT+COUTIME =aa bb cc,** 1324 -))) 1202 +* (% style="color:#037691" %)**Downlink Payload (prefix 0xA7):** 1325 1325 1204 +**0x A7 aa bb cc **~/~/ same as AT+COUTIME =aa bb cc, 1205 + 1326 1326 ((( 1327 1327 range: aa bb cc:0 to 16777215, (unit:second) 1328 1328 ... ... @@ -1330,6 +1330,7 @@ 1330 1330 ))) 1331 1331 1332 1332 1213 + 1333 1333 == 3.5 Integrate with Mydevice == 1334 1334 1335 1335 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: