... ... @@ -19,8 +19,6 @@
19 19  == 1.1 What is LT Series I/O Controller ==
20 20  
21 21  (((
22 -
23 -
24 24  The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring.
25 25  )))
26 26  
... ... @@ -50,7 +50,6 @@
50 50  
51 51  )))
52 52  
53 -
54 54  == 1.2  Specifications ==
55 55  
56 56  (((
... ... @@ -165,12 +165,10 @@
165 165  )))
166 166  * (((
167 167  Packet engine up to 256 bytes with CRC.
165 +)))
168 168  
169 169  
170 170  
171 -
172 -)))
173 -
174 174  == 1.3 Features ==
175 175  
176 176  * LoRaWAN Class A & Class C protocol
... ... @@ -183,7 +183,6 @@
183 183  
184 184  
185 185  
186 -
187 187  == 1.4  Applications ==
188 188  
189 189  * Smart Buildings & Home Automation
... ... @@ -195,7 +195,6 @@
195 195  
196 196  
197 197  
198 -
199 199  == 1.5 Hardware Variants ==
200 200  
201 201  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -292,8 +292,6 @@
292 292  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
293 293  
294 294  
295 -
296 -
297 297  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
298 298  
299 299  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -332,7 +332,6 @@
332 332  * [1] RO1 relay channel is close and the RO1 LED is ON.
333 333  * [0] RO2 relay channel is open and RO2 LED is OFF;
334 334  
335 -
336 336  **LT22222-L:**
337 337  
338 338  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -349,8 +349,6 @@
349 349  ** DO1 LED is off in both case
350 350  
351 351  
352 -
353 -
354 354  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
355 355  
356 356  
... ... @@ -491,10 +491,11 @@
491 491  
492 492  (((
493 493  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
482 +
483 +
494 494  )))
495 495  
496 496  
497 -
498 498  === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting ===
499 499  
500 500  
... ... @@ -776,6 +776,7 @@
776 776  )))
777 777  
778 778  
768 +
779 779  == 3.4 ​Configure LT via AT or Downlink ==
780 780  
781 781  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -2019,16 +2019,8 @@
2019 2019  )))
2020 2020  
2021 2021  (((
2022 -== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2012 +
2023 2023  
2024 -If the device is not shut down, but directly powered off.
2025 -
2026 -It will default that this is a power-off state.
2027 -
2028 -In modes 2 to 5, DO RO status and pulse count are saved in flash.
2029 -
2030 -After restart, the status before power failure will be read from flash.
2031 -
2032 2032  = 6. Trouble Shooting =