From version < 82.8 >
edited by Xiaoling
on 2022/06/20 11:18
To version < 79.3 >
edited by Xiaoling
on 2022/06/10 09:41
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,8 +19,6 @@
19 19  == 1.1 What is LT Series I/O Controller ==
20 20  
21 21  (((
22 -
23 -
24 24  The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring.
25 25  )))
26 26  
... ... @@ -50,7 +50,6 @@
50 50  
51 51  )))
52 52  
53 -
54 54  == 1.2  Specifications ==
55 55  
56 56  (((
... ... @@ -165,10 +165,6 @@
165 165  )))
166 166  * (((
167 167  Packet engine up to 256 bytes with CRC.
168 -
169 -
170 -
171 -
172 172  )))
173 173  
174 174  == 1.3 Features ==
... ... @@ -181,9 +181,6 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 -
185 -
186 -
187 187  == 1.4  Applications ==
188 188  
189 189  * Smart Buildings & Home Automation
... ... @@ -193,9 +193,6 @@
193 193  * Smart Cities
194 194  * Smart Factory
195 195  
196 -
197 -
198 -
199 199  == 1.5 Hardware Variants ==
200 200  
201 201  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -209,8 +209,6 @@
209 209  * 1 x Counting Port
210 210  )))
211 211  
212 -
213 -
214 214  = 2. Power ON Device =
215 215  
216 216  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -292,8 +292,6 @@
292 292  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
293 293  
294 294  
295 -
296 -
297 297  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
298 298  
299 299  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -332,6 +332,8 @@
332 332  * [1] RO1 relay channel is close and the RO1 LED is ON.
333 333  * [0] RO2 relay channel is open and RO2 LED is OFF;
334 334  
318 +
319 +
335 335  **LT22222-L:**
336 336  
337 337  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -347,6 +347,7 @@
347 347  ** DO1 is high in case there is load between DO1 and V+.
348 348  ** DO1 LED is off in both case
349 349  
335 +
350 350  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
351 351  
352 352  
... ... @@ -2015,16 +2015,8 @@
2015 2015  )))
2016 2016  
2017 2017  (((
2018 -== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2004 +
2019 2019  
2020 -If the device is not shut down, but directly powered off.
2021 -
2022 -It will default that this is a power-off state.
2023 -
2024 -In modes 2 to 5, DO RO status and pulse count are saved in flash.
2025 -
2026 -After restart, the status before power failure will be read from flash.
2027 -
2028 2028  = 6. Trouble Shooting =
2029 2029  )))
2030 2030  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved