From version < 82.8 >
edited by Xiaoling
on 2022/06/20 11:18
To version < 78.3 >
edited by Xiaoling
on 2022/06/10 09:39
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -19,8 +19,6 @@
19 19  == 1.1 What is LT Series I/O Controller ==
20 20  
21 21  (((
22 -
23 -
24 24  The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring.
25 25  )))
26 26  
... ... @@ -50,7 +50,6 @@
50 50  
51 51  )))
52 52  
53 -
54 54  == 1.2  Specifications ==
55 55  
56 56  (((
... ... @@ -165,12 +165,9 @@
165 165  )))
166 166  * (((
167 167  Packet engine up to 256 bytes with CRC.
168 -
169 -
170 -
171 -
172 172  )))
173 173  
167 +
174 174  == 1.3 Features ==
175 175  
176 176  * LoRaWAN Class A & Class C protocol
... ... @@ -182,8 +182,6 @@
182 182  * Counting
183 183  
184 184  
185 -
186 -
187 187  == 1.4  Applications ==
188 188  
189 189  * Smart Buildings & Home Automation
... ... @@ -194,8 +194,6 @@
194 194  * Smart Factory
195 195  
196 196  
197 -
198 -
199 199  == 1.5 Hardware Variants ==
200 200  
201 201  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -210,7 +210,6 @@
210 210  )))
211 211  
212 212  
213 -
214 214  = 2. Power ON Device =
215 215  
216 216  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -347,6 +347,9 @@
347 347  ** DO1 is high in case there is load between DO1 and V+.
348 348  ** DO1 LED is off in both case
349 349  
339 +
340 +
341 +
350 350  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
351 351  
352 352  
... ... @@ -487,6 +487,8 @@
487 487  
488 488  (((
489 489  Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]].
482 +
483 +
490 490  )))
491 491  
492 492  
... ... @@ -772,6 +772,7 @@
772 772  )))
773 773  
774 774  
769 +
775 775  == 3.4 ​Configure LT via AT or Downlink ==
776 776  
777 777  User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands
... ... @@ -2015,16 +2015,8 @@
2015 2015  )))
2016 2016  
2017 2017  (((
2018 -== 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==
2013 +
2019 2019  
2020 -If the device is not shut down, but directly powered off.
2021 -
2022 -It will default that this is a power-off state.
2023 -
2024 -In modes 2 to 5, DO RO status and pulse count are saved in flash.
2025 -
2026 -After restart, the status before power failure will be read from flash.
2027 -
2028 2028  = 6. Trouble Shooting =
2029 2029  )))
2030 2030  
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0