Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -19,8 +19,6 @@ 19 19 == 1.1 What is LT Series I/O Controller == 20 20 21 21 ((( 22 - 23 - 24 24 The Dragino (% style="color:blue" %)**LT series I/O Modules**(%%) are Long Range LoRaWAN I/O Controller. It contains different I/O Interfaces such as:** (% style="color:blue" %)analog current Input, analog voltage input(%%)**(% style="color:blue" %), **relay output**, **digital input**(%%) and (% style="color:blue" %)**digital output**(%%) etc. The LT I/O Modules are designed to simplify the installation of I/O monitoring. 25 25 ))) 26 26 ... ... @@ -50,7 +50,6 @@ 50 50 51 51 ))) 52 52 53 - 54 54 == 1.2 Specifications == 55 55 56 56 ((( ... ... @@ -79,8 +79,6 @@ 79 79 ))) 80 80 81 81 ((( 82 - 83 - 84 84 **Interface for Model: LT22222-L:** 85 85 ))) 86 86 ... ... @@ -104,8 +104,6 @@ 104 104 ))) 105 105 106 106 ((( 107 - 108 - 109 109 **LoRa Spec:** 110 110 ))) 111 111 ... ... @@ -166,8 +166,6 @@ 166 166 * ((( 167 167 Packet engine up to 256 bytes with CRC. 168 168 169 - 170 - 171 171 172 172 ))) 173 173 ... ... @@ -181,9 +181,6 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 - 185 - 186 - 187 187 == 1.4 Applications == 188 188 189 189 * Smart Buildings & Home Automation ... ... @@ -193,9 +193,6 @@ 193 193 * Smart Cities 194 194 * Smart Factory 195 195 196 - 197 - 198 - 199 199 == 1.5 Hardware Variants == 200 200 201 201 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -231,9 +231,12 @@ 231 231 232 232 ((( 233 233 In case user can’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 219 + 220 + 234 234 ))) 235 235 236 236 224 + 237 237 == 3.2 Example to join LoRaWAN network == 238 238 239 239 ((( ... ... @@ -242,13 +242,12 @@ 242 242 243 243 [[image:image-20220523172350-1.png||height="266" width="864"]] 244 244 245 - 246 246 ((( 247 247 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 248 248 ))) 249 249 250 250 ((( 251 - (% style="color:blue" %)**Step 1**(%%): Create a device in TTN with the OTAA keys from LT IO controller.238 +**Step 1**: Create a device in TTN with the OTAA keys from LT IO controller. 252 252 ))) 253 253 254 254 ((( ... ... @@ -257,7 +257,6 @@ 257 257 258 258 [[image:1653297924498-393.png]] 259 259 260 - 261 261 Input these keys in the LoRaWAN Server portal. Below is TTN screen shot: 262 262 263 263 Add APP EUI in the application. ... ... @@ -271,7 +271,7 @@ 271 271 272 272 273 273 ((( 274 - (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel.260 +**Step 2**: Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 275 275 ))) 276 276 277 277 [[image:1653298044601-602.png||height="405" width="709"]] ... ... @@ -289,6 +289,7 @@ 289 289 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 290 290 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 291 291 278 + 292 292 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 293 293 294 294 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -342,6 +342,7 @@ 342 342 ** DO1 is high in case there is load between DO1 and V+. 343 343 ** DO1 LED is off in both case 344 344 332 + 345 345 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 346 346 347 347 ... ... @@ -482,10 +482,11 @@ 482 482 483 483 ((( 484 484 Other AT Commands for counting are similar to [[MOD2 Counting Command>>||anchor="H3.3.2AT2BMOD3D22C28DoubleDICounting29"]]. 473 + 474 + 485 485 ))) 486 486 487 487 488 - 489 489 === 3.3.4 AT+MOD~=4, Single DI Counting + 1 x Voltage Counting === 490 490 491 491 ... ... @@ -633,11 +633,14 @@ 633 633 * **AT+MOD=1 ** **~-~->** The normal working mode 634 634 * **AT+ADDMOD6=1** **~-~->** Enable trigger 635 635 625 + 636 636 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 637 637 638 638 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 639 639 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 640 640 631 + 632 + 641 641 **AT Command to set Trigger Condition**: 642 642 643 643 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -717,6 +717,8 @@ 717 717 718 718 * Each bits shows if the corresponding trigger has been configured. 719 719 712 + 713 + 720 720 **Example:** 721 721 722 722 10100000: Means the system has configure to use the trigger: AC1_LOW and AV2_LOW ... ... @@ -728,6 +728,8 @@ 728 728 729 729 * Each bits shows which status has been trigger on this uplink. 730 730 725 + 726 + 731 731 **Example:** 732 732 733 733 10000000: Means this packet is trigger by AC1_LOW. Means voltage too low. ... ... @@ -739,6 +739,8 @@ 739 739 740 740 * Each bits shows which status has been trigger on this uplink. 741 741 738 + 739 + 742 742 **Example:** 743 743 744 744 00000111: Means both DI1 and DI2 trigger are enabled and this packet is trigger by DI1. ... ... @@ -767,6 +767,7 @@ 767 767 ))) 768 768 769 769 768 + 770 770 == 3.4 Configure LT via AT or Downlink == 771 771 772 772 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands ... ... @@ -779,6 +779,8 @@ 779 779 780 780 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 781 781 781 + 782 + 782 782 === 3.4.1 Common Commands === 783 783 784 784 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -2010,16 +2010,8 @@ 2010 2010 ))) 2011 2011 2012 2012 ((( 2013 - ==5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? ==2014 + 2014 2014 2015 -If the device is not shut down, but directly powered off. 2016 - 2017 -It will default that this is a power-off state. 2018 - 2019 -In modes 2 to 5, DO RO status and pulse count are saved in flash. 2020 - 2021 -After restart, the status before power failure will be read from flash. 2022 - 2023 2023 = 6. Trouble Shooting = 2024 2024 ))) 2025 2025