From version < 82.41 >
edited by Xiaoling
on 2022/06/25 15:18
To version < 83.10 >
edited by Xiaoling
on 2022/06/29 17:30
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,7 +1,6 @@
1 1  (% style="text-align:center" %)
2 2  [[image:image-20220523163353-1.jpeg||height="604" width="500"]]
3 3  
4 -**LT-22222-L LoRa IO Controller User Manual **
5 5  
6 6  
7 7  **Table of Contents:**
... ... @@ -167,7 +167,6 @@
167 167  Packet engine up to 256 bytes with CRC.
168 168  
169 169  
170 -
171 171  
172 172  )))
173 173  
... ... @@ -181,10 +181,6 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 -
185 -
186 -
187 -
188 188  == 1.4  Applications ==
189 189  
190 190  * Smart Buildings & Home Automation
... ... @@ -194,10 +194,6 @@
194 194  * Smart Cities
195 195  * Smart Factory
196 196  
197 -
198 -
199 -
200 -
201 201  == 1.5 Hardware Variants ==
202 202  
203 203  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -211,8 +211,6 @@
211 211  * 1 x Counting Port
212 212  )))
213 213  
214 -
215 -
216 216  = 2. Power ON Device =
217 217  
218 218  The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller.
... ... @@ -230,11 +230,11 @@
230 230  == 3.1 How it works? ==
231 231  
232 232  (((
233 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED** will be on for 1 second. 
221 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 
234 234  )))
235 235  
236 236  (((
237 -In case user cant set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
225 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.
238 238  )))
239 239  
240 240  
... ... @@ -286,18 +286,15 @@
286 286  
287 287  There are five working modes + one interrupt mode on LT for different type application:
288 288  
289 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO
290 -* **MOD2**: Double DI Counting + DO + RO
291 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO
292 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO
293 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
294 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
277 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO
278 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO
279 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO
280 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO
281 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
282 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5
295 295  
296 296  
297 297  
298 -
299 -
300 -
301 301  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
302 302  
303 303  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -337,6 +337,7 @@
337 337  * [0] RO2 relay channel is open and RO2 LED is OFF;
338 338  
339 339  
325 +
340 340  **LT22222-L:**
341 341  
342 342  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -354,9 +354,6 @@
354 354  
355 355  
356 356  
357 -
358 -
359 -
360 360  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
361 361  
362 362  
... ... @@ -430,6 +430,8 @@
430 430  [[image:image-20220523181246-5.png]]
431 431  
432 432  (((
416 +
417 +
433 433  (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below
434 434  )))
435 435  
... ... @@ -443,6 +443,7 @@
443 443  (% style="color:red" %)Note: DO3 is not valid for LT-22222-L.
444 444  )))
445 445  
431 +
446 446  (((
447 447  **To use counting mode, please run:**
448 448  )))
... ... @@ -575,8 +575,8 @@
575 575  
576 576  For example, if user has configured below commands:
577 577  
578 -* **AT+MOD=1 ** **~-~->** The normal working mode
579 -* **AT+ADDMOD6=1**   **~-~->** Enable trigger
564 +* **AT+MOD=1 ** **~-~->**  The normal working mode
565 +* **AT+ADDMOD6=1**   **~-~->**  Enable trigger
580 580  
581 581  LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases:
582 582  
... ... @@ -583,8 +583,10 @@
583 583  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
584 584  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
585 585  
572 +
586 586  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
587 587  
575 +
588 588  (% style="color:#4f81bd" %)**Trigger base on voltage**:
589 589  
590 590  Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH>
... ... @@ -726,9 +726,6 @@
726 726  
727 727  
728 728  
729 -
730 -
731 -
732 732  === 3.4.1 Common Commands ===
733 733  
734 734  They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]]
... ... @@ -867,8 +867,6 @@
867 867  * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):**
868 868  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
869 869  
870 -
871 -
872 872  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
873 873  
874 874  Set DI2 trigger.
... ... @@ -940,9 +940,14 @@
940 940  
941 941  **0x AC aa bb   ** ~/~/ same as AT+ATDC=0x(aa bb)   . Unit (min)
942 942  
926 +(((
927 +
943 943  
929 +(% style="color:red" %)Note: ATDC setting must be more than 5min
930 +)))
944 944  
945 945  
933 +
946 946  ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ====
947 947  
948 948  * (% style="color:#037691" %)**AT Command**
... ... @@ -1929,10 +1929,8 @@
1929 1929  )))
1930 1930  
1931 1931  
1932 -
1933 1933  = 7. Order Info =
1934 1934  
1935 -
1936 1936  (% style="color:#4f81bd" %)**LT-22222-L-XXX:**
1937 1937  
1938 1938  
... ... @@ -1948,8 +1948,6 @@
1948 1948  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1949 1949  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1950 1950  
1951 -
1952 -
1953 1953  = 8. Packing Info =
1954 1954  
1955 1955  
... ... @@ -1967,8 +1967,6 @@
1967 1967  * Package Size / pcs : 14.5 x 8 x 5 cm
1968 1968  * Weight / pcs : 170g
1969 1969  
1970 -
1971 -
1972 1972  = 9. Support =
1973 1973  
1974 1974  * (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0