Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -182,9 +182,6 @@ 182 182 * Counting 183 183 184 184 185 - 186 - 187 - 188 188 == 1.4 Applications == 189 189 190 190 * Smart Buildings & Home Automation ... ... @@ -195,9 +195,6 @@ 195 195 * Smart Factory 196 196 197 197 198 - 199 - 200 - 201 201 == 1.5 Hardware Variants == 202 202 203 203 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -213,6 +213,7 @@ 213 213 214 214 215 215 210 + 216 216 = 2. Power ON Device = 217 217 218 218 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -294,10 +294,6 @@ 294 294 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 295 295 296 296 297 - 298 - 299 - 300 - 301 301 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 302 302 303 303 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -336,7 +336,6 @@ 336 336 * [1] RO1 relay channel is close and the RO1 LED is ON. 337 337 * [0] RO2 relay channel is open and RO2 LED is OFF; 338 338 339 - 340 340 **LT22222-L:** 341 341 342 342 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -353,10 +353,6 @@ 353 353 ** DO1 LED is off in both case 354 354 355 355 356 - 357 - 358 - 359 - 360 360 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 361 361 362 362 ... ... @@ -406,20 +406,24 @@ 406 406 407 407 ((( 408 408 **For LT22222-L:** 395 +))) 409 409 397 +(% class="box infomessage" %) 398 +((( 399 +((( 400 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 410 410 411 - (% style="color:blue" %)**AT+TRIG1=0,100**(%%)**(set DI1 port to trigger onlowlevel, valid signal is 100ms) **402 +**AT+TRIG1=1,100 (set DI1 port to trigger on high level, valid signal is 100ms ) ** 412 412 413 - (% style="color:blue" %)**AT+TRIG1=1,100**(%%)**(set DI1port to trigger onhighlevel, valid signal is 100ms404 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 414 414 415 - (% style="color:blue" %)**AT+TRIG2=0,100**(%%)**(set DI2 port to trigger onlowlevel, valid signal is 100ms) **406 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 416 416 417 - (% style="color:blue" %)**AT+TRIG2=1,100**(%%)**setDI2port to trigger on high level, validsignalis 100ms)408 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 418 418 419 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 420 - 421 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 410 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 422 422 ))) 412 +))) 423 423 424 424 425 425 ... ... @@ -511,8 +511,11 @@ 511 511 512 512 513 513 **Plus below command for AVI1 Counting:** 504 +))) 514 514 515 - 506 +(% class="box infomessage" %) 507 +((( 508 +((( 516 516 (% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 517 517 518 518 (% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** ... ... @@ -521,9 +521,9 @@ 521 521 522 522 (% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 523 523 ))) 517 +))) 524 524 525 525 526 - 527 527 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 528 528 529 529 ... ... @@ -583,6 +583,7 @@ 583 583 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 584 584 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 585 585 579 + 586 586 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 587 587 588 588 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -725,10 +725,6 @@ 725 725 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 726 726 727 727 728 - 729 - 730 - 731 - 732 732 === 3.4.1 Common Commands === 733 733 734 734 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -743,19 +743,23 @@ 743 743 744 744 * (% style="color:#037691" %)**AT Command:** 745 745 736 +(% class="box infomessage" %) 737 +((( 746 746 **AT+TDC=N ** 739 +))) 747 747 748 - 749 749 **Example: **AT+TDC=30000. Means set interval to 30 seconds 750 750 751 751 752 752 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 753 753 746 +(% class="box infomessage" %) 747 +((( 754 754 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 749 +))) 755 755 756 756 757 757 758 - 759 759 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 760 760 761 761 Set work mode. ... ... @@ -762,29 +762,36 @@ 762 762 763 763 * (% style="color:#037691" %)**AT Command:** 764 764 759 +(% class="box infomessage" %) 760 +((( 765 765 **AT+MOD=N ** 762 +))) 766 766 767 - 768 768 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 769 769 770 770 771 771 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 772 772 773 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 769 +(% class="box infomessage" %) 770 +((( 771 +**0x0A aa ~/~/ Same as AT+MOD=aa** 772 +))) 774 774 775 775 776 776 777 - 778 778 ==== 3.4.2.3 Poll an uplink ==== 779 779 780 -* (% style="color:#037691" %) **AT Command:**778 +* (% style="color:#037691" %)AT Command: 781 781 782 782 There is no AT Command to poll uplink 783 783 784 784 785 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x08):**783 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 786 786 787 -**0x08 FF **~/~/ Poll an uplink 785 +(% class="box infomessage" %) 786 +((( 787 +**0x08 FF ~/~/ Poll an uplink,** 788 +))) 788 788 789 789 **Example**: 0x08FF, ask device to send an Uplink 790 790 ... ... @@ -794,9 +794,12 @@ 794 794 795 795 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 796 796 797 -* (% style="color:#037691" %) **AT Command:**798 +* (% style="color:#037691" %)AT Command: 798 798 800 +(% class="box infomessage" %) 801 +((( 799 799 **AT+ADDMOD6=1 or 0** 803 +))) 800 800 801 801 1: Enable Trigger Mode 802 802 ... ... @@ -803,34 +803,38 @@ 803 803 0: Disable Trigger Mode 804 804 805 805 806 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x0A 06):**810 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 807 807 808 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 812 +(% class="box infomessage" %) 813 +((( 814 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 815 +))) 809 809 810 810 811 811 812 - 813 813 ==== 3.4.2.5 Poll trigger settings ==== 814 814 815 815 Poll trigger settings, 816 816 817 -* (% style="color:#037691" %) **AT Command:**823 +* (% style="color:#037691" %)AT Command: 818 818 819 819 There is no AT Command for this feature. 820 820 821 821 822 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**828 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 823 823 824 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 830 +(% class="box infomessage" %) 831 +((( 832 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 833 +))) 825 825 826 826 827 827 828 - 829 829 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 830 830 831 831 Enable Disable DI1/DI2/DI2 as trigger, 832 832 833 -* (% style="color:#037691" %) **AT Command:**841 +* (% style="color:#037691" %)AT Command: 834 834 835 835 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 836 836 ... ... @@ -839,7 +839,7 @@ 839 839 840 840 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 841 841 842 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**850 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 843 843 844 844 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 845 845 ... ... @@ -850,7 +850,7 @@ 850 850 851 851 Set DI1 or DI3(for LT-33222-L) trigger. 852 852 853 -* (% style="color:#037691" %) **AT Command:**861 +* (% style="color:#037691" %)AT Command: 854 854 855 855 **AT+TRIG1=a,b** 856 856 ... ... @@ -929,11 +929,11 @@ 929 929 930 930 ==== 3.4.2.11 Trigger – Set minimum interval ==== 931 931 932 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.940 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 933 933 934 934 * (% style="color:#037691" %)**AT Command** 935 935 936 -**AT+ATDC=5 **Device won't response the second trigger within 5 minute after the first trigger.944 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 937 937 938 938 939 939 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -1129,7 +1129,7 @@ 1129 1129 1130 1130 * (% style="color:#037691" %)**AT Command:** 1131 1131 1132 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1140 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1133 1133 1134 1134 1135 1135 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1143,7 +1143,7 @@ 1143 1143 1144 1144 * (% style="color:#037691" %)**AT Command:** 1145 1145 1146 -**AT+SETCNT=aa,(bb cc dd ee) ** 1154 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1147 1147 1148 1148 aa: 1: Set count1, 1149 1149 ... ... @@ -1167,7 +1167,7 @@ 1167 1167 1168 1168 * (% style="color:#037691" %)**AT Command:** 1169 1169 1170 -**AT+CLRCOUNT ** ~/~/ clear all counting 1178 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1171 1171 1172 1172 1173 1173 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1425,7 +1425,6 @@ 1425 1425 [[image:image-20220524100748-11.png]] 1426 1426 1427 1427 1428 - 1429 1429 = 4. Use AT Command = 1430 1430 1431 1431 == 4.1 Access AT Command == ... ... @@ -1628,6 +1628,8 @@ 1628 1628 1629 1629 ((( 1630 1630 AT+CFG: Print all settings 1638 + 1639 + 1631 1631 ))) 1632 1632 1633 1633 ... ... @@ -1673,6 +1673,8 @@ 1673 1673 1674 1674 ((( 1675 1675 (% style="background-color:#dcdcdc" %)ATZ 1685 + 1686 + 1676 1676 ))) 1677 1677 1678 1678 ... ... @@ -1879,8 +1879,6 @@ 1879 1879 == 5.5 Can i use point to point communication for LT-22222-L? == 1880 1880 1881 1881 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1882 - 1883 - 1884 1884 ))) 1885 1885 1886 1886 ((( ... ... @@ -1894,7 +1894,6 @@ 1894 1894 1895 1895 After restart, the status before power failure will be read from flash. 1896 1896 1897 - 1898 1898 = 6. Trouble Shooting = 1899 1899 ))) 1900 1900 ... ... @@ -1948,8 +1948,6 @@ 1948 1948 * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1949 1949 * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1950 1950 1951 - 1952 - 1953 1953 = 8. Packing Info = 1954 1954 1955 1955 ... ... @@ -1967,8 +1967,6 @@ 1967 1967 * Package Size / pcs : 14.5 x 8 x 5 cm 1968 1968 * Weight / pcs : 170g 1969 1969 1970 - 1971 - 1972 1972 = 9. Support = 1973 1973 1974 1974 * ((( ... ... @@ -1976,10 +1976,6 @@ 1976 1976 ))) 1977 1977 * ((( 1978 1978 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1979 - 1980 - 1981 - 1982 - 1983 1983 ))) 1984 1984 1985 1985 = 10. Reference =