<
From version < 82.40 >
edited by Xiaoling
on 2022/06/25 15:14
To version < 82.37 >
edited by Xiaoling
on 2022/06/20 13:59
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -181,10 +181,6 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 -
185 -
186 -
187 -
188 188  == 1.4  Applications ==
189 189  
190 190  * Smart Buildings & Home Automation
... ... @@ -194,10 +194,6 @@
194 194  * Smart Cities
195 195  * Smart Factory
196 196  
197 -
198 -
199 -
200 -
201 201  == 1.5 Hardware Variants ==
202 202  
203 203  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -293,11 +293,6 @@
293 293  * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO
294 294  * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5
295 295  
296 -
297 -
298 -
299 -
300 -
301 301  === 3.3.1 AT+MOD~=1, 2ACI+2AVI ===
302 302  
303 303  The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default.
... ... @@ -336,7 +336,6 @@
336 336  * [1] RO1 relay channel is close and the RO1 LED is ON.
337 337  * [0] RO2 relay channel is open and RO2 LED is OFF;
338 338  
339 -
340 340  **LT22222-L:**
341 341  
342 342  * [1] DI2 channel is high input and DI2 LED is ON;
... ... @@ -352,11 +352,6 @@
352 352  ** DO1 is high in case there is load between DO1 and V+.
353 353  ** DO1 LED is off in both case
354 354  
355 -
356 -
357 -
358 -
359 -
360 360  === 3.3.2 AT+MOD~=2, (Double DI Counting) ===
361 361  
362 362  
... ... @@ -583,6 +583,7 @@
583 583  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
584 584  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
585 585  
567 +
586 586  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
587 587  
588 588  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -816,7 +816,7 @@
816 816  
817 817  * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
818 818  
819 -**0xAB 06         **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
801 +**0xAB 06  **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
820 820  
821 821  
822 822  
... ... @@ -864,6 +864,7 @@
864 864  
865 865  
866 866  
849 +
867 867  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
868 868  
869 869  Set DI2 trigger.
... ... @@ -928,7 +928,7 @@
928 928  
929 929  * (% style="color:#037691" %)**AT Command**
930 930  
931 -**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
914 +**AT+ATDC=5  ** Device won't response the second trigger within 5 minute after the first trigger.
932 932  
933 933  
934 934  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
... ... @@ -1162,7 +1162,7 @@
1162 1162  
1163 1163  * (% style="color:#037691" %)**AT Command:**
1164 1164  
1165 -**AT+CLRCOUNT ** ~/~/ clear all counting
1148 +(% style="color:#037691" %)​​​​​​​(%%)**AT+CLRCOUNT ** ~/~/ clear all counting
1166 1166  
1167 1167  
1168 1168  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
... ... @@ -1945,6 +1945,7 @@
1945 1945  
1946 1946  
1947 1947  
1931 +
1948 1948  = 8. Packing Info =
1949 1949  
1950 1950  
... ... @@ -1964,6 +1964,7 @@
1964 1964  
1965 1965  
1966 1966  
1951 +
1967 1967  = 9. Support =
1968 1968  
1969 1969  * (((
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0