From version < 82.39 >
edited by Xiaoling
on 2022/06/25 15:12
To version < 82.32 >
edited by Xiaoling
on 2022/06/20 13:36
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -181,10 +181,6 @@
181 181  * Firmware upgradable via program port
182 182  * Counting
183 183  
184 -
185 -
186 -
187 -
188 188  == 1.4  Applications ==
189 189  
190 190  * Smart Buildings & Home Automation
... ... @@ -194,10 +194,6 @@
194 194  * Smart Cities
195 195  * Smart Factory
196 196  
197 -
198 -
199 -
200 -
201 201  == 1.5 Hardware Variants ==
202 202  
203 203  (% border="1" style="background-color:#f7faff; width:500px" %)
... ... @@ -572,6 +572,7 @@
572 572  1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type
573 573  1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.**
574 574  
567 +
575 575  (% style="color:#037691" %)**AT Command to set Trigger Condition**:
576 576  
577 577  (% style="color:#4f81bd" %)**Trigger base on voltage**:
... ... @@ -754,7 +754,7 @@
754 754  
755 755  * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):**
756 756  
757 -**0x0A aa    ** ~/~/ Same as AT+MOD=aa
750 +(% style="color:#037691" %)**​​​​​​​**(%%)**0x0A aa    ** ~/~/ Same as AT+MOD=aa
758 758  
759 759  
760 760  
... ... @@ -791,6 +791,10 @@
791 791  
792 792  **0x0A 06 aa    ** ~/~/ Same as AT+ADDMOD6=aa
793 793  
787 +(% class="box infomessage" %)
788 +(((
789 +
790 +)))
794 794  
795 795  
796 796  
... ... @@ -798,23 +798,25 @@
798 798  
799 799  Poll trigger settings,
800 800  
801 -* (% style="color:#037691" %)**AT Command:**
798 +* (% style="color:#037691" %)AT Command:
802 802  
803 803  There is no AT Command for this feature.
804 804  
805 805  
806 -* (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):**
803 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06):
807 807  
808 -**0xAB 06         **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command
805 +(% class="box infomessage" %)
806 +(((
807 +**0xAB 06  ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command**
808 +)))
809 809  
810 810  
811 811  
812 -
813 813  ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ====
814 814  
815 815  Enable Disable DI1/DI2/DI2 as trigger,
816 816  
817 -* (% style="color:#037691" %)**AT Command:**
816 +* (% style="color:#037691" %)AT Command:
818 818  
819 819  **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >**
820 820  
... ... @@ -823,7 +823,7 @@
823 823  
824 824  AT+ DTRI =1,0   (Enable DI1 trigger / disable DI2 trigger)
825 825  
826 -* (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 02):**
825 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02):
827 827  
828 828  **0xAA 02 aa bb        **~/~/ Same as AT+DTRI=aa,bb
829 829  
... ... @@ -834,7 +834,7 @@
834 834  
835 835  Set DI1 or DI3(for LT-33222-L) trigger.
836 836  
837 -* (% style="color:#037691" %)**AT Command:**
836 +* (% style="color:#037691" %)AT Command:
838 838  
839 839  **AT+TRIG1=a,b**
840 840  
... ... @@ -852,7 +852,6 @@
852 852  * **0x09 01 aa bb cc    ** ~/~/ same as AT+TRIG1=aa,0x(bb cc)
853 853  
854 854  
855 -
856 856  ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ====
857 857  
858 858  Set DI2 trigger.
... ... @@ -913,11 +913,11 @@
913 913  
914 914  ==== 3.4.2.11 Trigger – Set minimum interval ====
915 915  
916 -Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger.
914 +Set AV and AC trigger minimum interval, system wont response to the second trigger within this set time after the first trigger.
917 917  
918 918  * (% style="color:#037691" %)**AT Command**
919 919  
920 -**AT+ATDC=5        ** Device won't response the second trigger within 5 minute after the first trigger.
918 +**AT+ATDC=5. Device wont response the second trigger within 5 minute after the first trigger.**
921 921  
922 922  
923 923  * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )**
... ... @@ -1127,7 +1127,7 @@
1127 1127  
1128 1128  * (% style="color:#037691" %)**AT Command:**
1129 1129  
1130 -**AT+SETCNT=aa,(bb cc dd ee) **
1128 +(% style="color:#037691" %)**​​​​​​​​​​​​​​**(%%)**AT+SETCNT=aa,(bb cc dd ee) **
1131 1131  
1132 1132  aa: 1: Set count1,
1133 1133  
... ... @@ -1151,7 +1151,7 @@
1151 1151  
1152 1152  * (% style="color:#037691" %)**AT Command:**
1153 1153  
1154 -**AT+CLRCOUNT ** ~/~/ clear all counting
1152 +(% style="color:#037691" %)​​​​​​​​​​​​​​(%%)**AT+CLRCOUNT ** ~/~/ clear all counting
1155 1155  
1156 1156  
1157 1157  * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**
... ... @@ -1409,7 +1409,6 @@
1409 1409  [[image:image-20220524100748-11.png]]
1410 1410  
1411 1411  
1412 -
1413 1413  = 4. Use AT Command =
1414 1414  
1415 1415  == 4.1 Access AT Command ==
... ... @@ -1612,6 +1612,8 @@
1612 1612  
1613 1613  (((
1614 1614  AT+CFG: Print all settings
1612 +
1613 +
1615 1615  )))
1616 1616  
1617 1617  
... ... @@ -1657,6 +1657,8 @@
1657 1657  
1658 1658  (((
1659 1659  (% style="background-color:#dcdcdc" %)ATZ
1659 +
1660 +
1660 1660  )))
1661 1661  
1662 1662  
... ... @@ -1863,8 +1863,6 @@
1863 1863  == 5.5 Can i use point to point communication for LT-22222-L? ==
1864 1864  
1865 1865  Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]]
1866 -
1867 -
1868 1868  )))
1869 1869  
1870 1870  (((
... ... @@ -1878,7 +1878,6 @@
1878 1878  
1879 1879  After restart, the status before power failure will be read from flash.
1880 1880  
1881 -
1882 1882  = 6. Trouble Shooting =
1883 1883  )))
1884 1884  
... ... @@ -1932,8 +1932,6 @@
1932 1932  * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865
1933 1933  * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779
1934 1934  
1935 -
1936 -
1937 1937  = 8. Packing Info =
1938 1938  
1939 1939  
... ... @@ -1951,8 +1951,6 @@
1951 1951  * Package Size / pcs : 14.5 x 8 x 5 cm
1952 1952  * Weight / pcs : 170g
1953 1953  
1954 -
1955 -
1956 1956  = 9. Support =
1957 1957  
1958 1958  * (((
... ... @@ -1960,10 +1960,6 @@
1960 1960  )))
1961 1961  * (((
1962 1962  Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]]
1963 -
1964 -
1965 -
1966 -
1967 1967  )))
1968 1968  
1969 1969  = 10. Reference​​​​​ =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved