Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -182,9 +182,6 @@ 182 182 * Counting 183 183 184 184 185 - 186 - 187 - 188 188 == 1.4 Applications == 189 189 190 190 * Smart Buildings & Home Automation ... ... @@ -195,9 +195,6 @@ 195 195 * Smart Factory 196 196 197 197 198 - 199 - 200 - 201 201 == 1.5 Hardware Variants == 202 202 203 203 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -213,6 +213,7 @@ 213 213 214 214 215 215 210 + 216 216 = 2. Power ON Device = 217 217 218 218 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -293,6 +293,7 @@ 293 293 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 294 294 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 295 295 291 + 296 296 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 297 297 298 298 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -346,6 +346,7 @@ 346 346 ** DO1 is high in case there is load between DO1 and V+. 347 347 ** DO1 LED is off in both case 348 348 345 + 349 349 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 350 350 351 351 ... ... @@ -397,17 +397,17 @@ 397 397 **For LT22222-L:** 398 398 399 399 400 - (% style="color:blue" %)**AT+TRIG1=0,100**(%%)**(set DI1 port to trigger on low level, valid signal is 100ms) **397 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 401 401 402 - (% style="color:blue" %)**AT+TRIG1=1,100**(%%)**(set DI1 port to trigger on high level, valid signal is 100ms ) **399 +**AT+TRIG1=1,100 (set DI1 port to trigger on high level, valid signal is 100ms ) ** 403 403 404 - (% style="color:blue" %)**AT+TRIG2=0,100**(%%)**(set DI2 port to trigger on low level, valid signal is 100ms) **401 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 405 405 406 - (% style="color:blue" %)**AT+TRIG2=1,100**(%%)**(set DI2 port to trigger on high level, valid signal is 100ms ) **403 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 407 407 408 - (% style="color:blue" %)**AT+SETCNT=1,60**(%%)**(Set COUNT1 value to 60)**405 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 409 409 410 - (% style="color:blue" %)**AT+SETCNT=2,60**(%%)**(Set COUNT2 value to 60)**407 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 411 411 ))) 412 412 413 413 ... ... @@ -572,6 +572,7 @@ 572 572 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 573 573 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 574 574 572 + 575 575 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 576 576 577 577 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -713,6 +713,7 @@ 713 713 714 714 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 715 715 714 + 716 716 === 3.4.1 Common Commands === 717 717 718 718 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -727,19 +727,23 @@ 727 727 728 728 * (% style="color:#037691" %)**AT Command:** 729 729 729 +(% class="box infomessage" %) 730 +((( 730 730 **AT+TDC=N ** 732 +))) 731 731 732 - 733 733 **Example: **AT+TDC=30000. Means set interval to 30 seconds 734 734 735 735 736 736 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 737 737 739 +(% class="box infomessage" %) 740 +((( 738 738 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 742 +))) 739 739 740 740 741 741 742 - 743 743 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 744 744 745 745 Set work mode. ... ... @@ -746,29 +746,36 @@ 746 746 747 747 * (% style="color:#037691" %)**AT Command:** 748 748 752 +(% class="box infomessage" %) 753 +((( 749 749 **AT+MOD=N ** 755 +))) 750 750 751 - 752 752 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 753 753 754 754 755 755 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 756 756 757 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 762 +(% class="box infomessage" %) 763 +((( 764 +**0x0A aa ~/~/ Same as AT+MOD=aa** 765 +))) 758 758 759 759 760 760 761 - 762 762 ==== 3.4.2.3 Poll an uplink ==== 763 763 764 -* (% style="color:#037691" %) **AT Command:**771 +* (% style="color:#037691" %)AT Command: 765 765 766 766 There is no AT Command to poll uplink 767 767 768 768 769 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x08):**776 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 770 770 771 -**0x08 FF **~/~/ Poll an uplink 778 +(% class="box infomessage" %) 779 +((( 780 +**0x08 FF ~/~/ Poll an uplink,** 781 +))) 772 772 773 773 **Example**: 0x08FF, ask device to send an Uplink 774 774 ... ... @@ -778,9 +778,12 @@ 778 778 779 779 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 780 780 781 -* (% style="color:#037691" %) **AT Command:**791 +* (% style="color:#037691" %)AT Command: 782 782 793 +(% class="box infomessage" %) 794 +((( 783 783 **AT+ADDMOD6=1 or 0** 796 +))) 784 784 785 785 1: Enable Trigger Mode 786 786 ... ... @@ -787,34 +787,38 @@ 787 787 0: Disable Trigger Mode 788 788 789 789 790 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x0A 06):**803 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 791 791 792 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 805 +(% class="box infomessage" %) 806 +((( 807 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 808 +))) 793 793 794 794 795 795 796 - 797 797 ==== 3.4.2.5 Poll trigger settings ==== 798 798 799 799 Poll trigger settings, 800 800 801 -* (% style="color:#037691" %) **AT Command:**816 +* (% style="color:#037691" %)AT Command: 802 802 803 803 There is no AT Command for this feature. 804 804 805 805 806 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**821 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 807 807 808 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 823 +(% class="box infomessage" %) 824 +((( 825 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 826 +))) 809 809 810 810 811 811 812 - 813 813 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 814 814 815 815 Enable Disable DI1/DI2/DI2 as trigger, 816 816 817 -* (% style="color:#037691" %) **AT Command:**834 +* (% style="color:#037691" %)AT Command: 818 818 819 819 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 820 820 ... ... @@ -823,7 +823,7 @@ 823 823 824 824 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 825 825 826 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**843 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 827 827 828 828 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 829 829 ... ... @@ -834,7 +834,7 @@ 834 834 835 835 Set DI1 or DI3(for LT-33222-L) trigger. 836 836 837 -* (% style="color:#037691" %) **AT Command:**854 +* (% style="color:#037691" %)AT Command: 838 838 839 839 **AT+TRIG1=a,b** 840 840 ... ... @@ -913,11 +913,11 @@ 913 913 914 914 ==== 3.4.2.11 Trigger – Set minimum interval ==== 915 915 916 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.933 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 917 917 918 918 * (% style="color:#037691" %)**AT Command** 919 919 920 -**AT+ATDC=5 **Device won't response the second trigger within 5 minute after the first trigger.937 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 921 921 922 922 923 923 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -1127,7 +1127,7 @@ 1127 1127 1128 1128 * (% style="color:#037691" %)**AT Command:** 1129 1129 1130 -**AT+SETCNT=aa,(bb cc dd ee) ** 1147 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1131 1131 1132 1132 aa: 1: Set count1, 1133 1133 ... ... @@ -1151,7 +1151,7 @@ 1151 1151 1152 1152 * (% style="color:#037691" %)**AT Command:** 1153 1153 1154 -**AT+CLRCOUNT ** ~/~/ clear all counting 1171 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1155 1155 1156 1156 1157 1157 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1409,7 +1409,6 @@ 1409 1409 [[image:image-20220524100748-11.png]] 1410 1410 1411 1411 1412 - 1413 1413 = 4. Use AT Command = 1414 1414 1415 1415 == 4.1 Access AT Command == ... ... @@ -1612,6 +1612,8 @@ 1612 1612 1613 1613 ((( 1614 1614 AT+CFG: Print all settings 1631 + 1632 + 1615 1615 ))) 1616 1616 1617 1617 ... ... @@ -1657,6 +1657,8 @@ 1657 1657 1658 1658 ((( 1659 1659 (% style="background-color:#dcdcdc" %)ATZ 1678 + 1679 + 1660 1660 ))) 1661 1661 1662 1662 ... ... @@ -1863,8 +1863,6 @@ 1863 1863 == 5.5 Can i use point to point communication for LT-22222-L? == 1864 1864 1865 1865 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1866 - 1867 - 1868 1868 ))) 1869 1869 1870 1870 ((( ... ... @@ -1878,7 +1878,6 @@ 1878 1878 1879 1879 After restart, the status before power failure will be read from flash. 1880 1880 1881 - 1882 1882 = 6. Trouble Shooting = 1883 1883 ))) 1884 1884 ... ... @@ -1932,8 +1932,6 @@ 1932 1932 * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1933 1933 * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1934 1934 1935 - 1936 - 1937 1937 = 8. Packing Info = 1938 1938 1939 1939 ... ... @@ -1951,8 +1951,6 @@ 1951 1951 * Package Size / pcs : 14.5 x 8 x 5 cm 1952 1952 * Weight / pcs : 170g 1953 1953 1954 - 1955 - 1956 1956 = 9. Support = 1957 1957 1958 1958 * ((( ... ... @@ -1960,10 +1960,6 @@ 1960 1960 ))) 1961 1961 * ((( 1962 1962 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1963 - 1964 - 1965 - 1966 - 1967 1967 ))) 1968 1968 1969 1969 = 10. Reference =