Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -181,10 +181,6 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 - 185 - 186 - 187 - 188 188 == 1.4 Applications == 189 189 190 190 * Smart Buildings & Home Automation ... ... @@ -194,10 +194,6 @@ 194 194 * Smart Cities 195 195 * Smart Factory 196 196 197 - 198 - 199 - 200 - 201 201 == 1.5 Hardware Variants == 202 202 203 203 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -212,6 +212,7 @@ 212 212 ))) 213 213 214 214 207 + 215 215 = 2. Power ON Device = 216 216 217 217 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -571,6 +571,7 @@ 571 571 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 572 572 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 573 573 567 + 574 574 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 575 575 576 576 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -804,7 +804,7 @@ 804 804 805 805 * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 806 806 807 -**0xAB 06 801 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 808 808 809 809 810 810 ... ... @@ -852,6 +852,7 @@ 852 852 853 853 854 854 849 + 855 855 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 856 856 857 857 Set DI2 trigger. ... ... @@ -916,7 +916,7 @@ 916 916 917 917 * (% style="color:#037691" %)**AT Command** 918 918 919 -**AT+ATDC=5 914 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 920 920 921 921 922 922 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -1150,7 +1150,7 @@ 1150 1150 1151 1151 * (% style="color:#037691" %)**AT Command:** 1152 1152 1153 -**AT+CLRCOUNT ** ~/~/ clear all counting 1148 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1154 1154 1155 1155 1156 1156 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1933,6 +1933,7 @@ 1933 1933 1934 1934 1935 1935 1931 + 1936 1936 = 8. Packing Info = 1937 1937 1938 1938 ... ... @@ -1952,6 +1952,7 @@ 1952 1952 1953 1953 1954 1954 1951 + 1955 1955 = 9. Support = 1956 1956 1957 1957 * (((