Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220523163353-1.jpeg||height="604" width="500"]] 3 3 4 -**LT-22222-L LoRa IO Controller User Manual ** 5 5 6 6 7 7 **Table of Contents:** ... ... @@ -42,6 +42,8 @@ 42 42 43 43 ((( 44 44 2) User can set up a LoRaWAN gateway locally and configure the controller to connect to the gateway via wireless. 44 + 45 + 45 45 ))) 46 46 47 47 ((( ... ... @@ -173,6 +173,7 @@ 173 173 174 174 == 1.3 Features == 175 175 177 + 176 176 * LoRaWAN Class A & Class C protocol 177 177 * Optional Customized LoRa Protocol 178 178 * Frequency Bands: CN470/EU433/KR920/US915/EU868/AS923/AU915/RU864/IN865 ... ... @@ -181,8 +181,12 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 186 + 187 + 188 + 184 184 == 1.4 Applications == 185 185 191 + 186 186 * Smart Buildings & Home Automation 187 187 * Logistics and Supply Chain Management 188 188 * Smart Metering ... ... @@ -190,8 +190,12 @@ 190 190 * Smart Cities 191 191 * Smart Factory 192 192 199 + 200 + 201 + 193 193 == 1.5 Hardware Variants == 194 194 204 + 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) 196 196 |(% style="width:103px" %)**Model**|(% style="width:131px" %)**Photo**|(% style="width:334px" %)**Description** 197 197 |(% style="width:103px" %)**LT22222-L**|(% style="width:131px" %)[[image:1653296302983-697.png]]|(% style="width:334px" %)((( ... ... @@ -207,6 +207,7 @@ 207 207 208 208 = 2. Power ON Device = 209 209 220 + 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. 211 211 212 212 ((( ... ... @@ -221,19 +221,24 @@ 221 221 222 222 == 3.1 How it works? == 223 223 235 + 224 224 ((( 225 -The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on **TX LED** will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. **TX LED** will be on for 5 seconds after joined in network. When there is message from server, the **RX LED**will be on for 1 second.237 +The LT is configured as LoRaWAN OTAA Class C mode by default. It has OTAA keys to join network. To connect a local LoRaWAN network, user just need to input the OTAA keys in the network server and power on the LT. It will auto join the network via OTAA. For LT-22222-L, the LED will show the Join status: After power on (% style="color:green" %)**TX LED**(%%) will fast blink 5 times, LT-22222-L will enter working mode and start to JOIN LoRaWAN network. (% style="color:green" %)**TX LED**(%%) will be on for 5 seconds after joined in network. When there is message from server, the RX LED will be on for 1 second. 226 226 ))) 227 227 228 228 ((( 229 -In case user can ’t set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices.241 +In case user can't set the OTAA keys in the network server and has to use the existing keys from server. User can [[use AT Command>>||anchor="H4.UseATCommand"]] to set the keys in the devices. 230 230 ))) 231 231 232 232 245 + 233 233 == 3.2 Example to join LoRaWAN network == 234 234 248 + 235 235 ((( 236 236 This chapter shows an example for how to join the TTN LoRaWAN Network. Below is the network structure, we use our LG308 as LoRaWAN gateway here. 251 + 252 + 237 237 ))) 238 238 239 239 [[image:image-20220523172350-1.png||height="266" width="864"]] ... ... @@ -241,6 +241,8 @@ 241 241 242 242 ((( 243 243 The LG308 is already set to connect to [[TTN network >>url:https://www.thethingsnetwork.org/]]. So what we need to do now is only configure register this device to TTN: 260 + 261 + 244 244 ))) 245 245 246 246 ((( ... ... @@ -266,6 +266,7 @@ 266 266 [[image:1653298023685-319.png]] 267 267 268 268 287 + 269 269 ((( 270 270 (% style="color:blue" %)**Step 2**(%%): Power on LT and it will auto join to the TTN network. After join success, it will start to upload message to TTN and user can see in the panel. 271 271 ))) ... ... @@ -276,17 +276,22 @@ 276 276 277 277 == 3.3 Uplink Payload == 278 278 298 + 279 279 There are five working modes + one interrupt mode on LT for different type application: 280 280 281 -* **MOD1**: (default setting): 2 x ACI + 2AVI + DI + DO + RO 282 -* **MOD2**: Double DI Counting + DO + RO 283 -* **MOD3**: Single DI Counting + 2 x ACI + DO + RO 284 -* **MOD4**: Single DI Counting + 1 x Voltage Counting + DO + RO 285 -* **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 -* **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 301 +* (% style="color:blue" %)**MOD1**(%%): (default setting): 2 x ACI + 2AVI + DI + DO + RO 302 +* (% style="color:blue" %)**MOD2**(%%): Double DI Counting + DO + RO 303 +* (% style="color:blue" %)**MOD3**(%%): Single DI Counting + 2 x ACI + DO + RO 304 +* (% style="color:blue" %)**MOD4**(%%): Single DI Counting + 1 x Voltage Counting + DO + RO 305 +* (% style="color:blue" %)**MOD5**(%%): Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 306 +* (% style="color:blue" %)**ADDMOD6**(%%): Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 308 + 309 + 310 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 313 + 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. 291 291 292 292 [[image:image-20220523174024-3.png]] ... ... @@ -323,6 +323,7 @@ 323 323 * [1] RO1 relay channel is close and the RO1 LED is ON. 324 324 * [0] RO2 relay channel is open and RO2 LED is OFF; 325 325 350 + 326 326 **LT22222-L:** 327 327 328 328 * [1] DI2 channel is high input and DI2 LED is ON; ... ... @@ -338,6 +338,9 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 366 + 367 + 368 + 341 341 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 342 342 343 343 ... ... @@ -406,11 +406,14 @@ 406 406 407 407 === 3.3.3 AT+MOD~=3, Single DI Counting + 2 x ACI === 408 408 437 + 409 409 **LT22222-L**: This mode the DI1 is used as a counting pin. 410 410 411 411 [[image:image-20220523181246-5.png]] 412 412 413 413 ((( 443 + 444 + 414 414 (% style="color:#4f81bd" %)**DIDORO**(%%) is a combination for RO1, RO2, DI3, DI2, DI1, DO3, DO2 and DO1. Totally 1bytes as below 415 415 ))) 416 416 ... ... @@ -424,6 +424,7 @@ 424 424 (% style="color:red" %)Note: DO3 is not valid for LT-22222-L. 425 425 ))) 426 426 458 + 427 427 ((( 428 428 **To use counting mode, please run:** 429 429 ))) ... ... @@ -556,8 +556,8 @@ 556 556 557 557 For example, if user has configured below commands: 558 558 559 -* **AT+MOD=1 ** **~-~->** The normal working mode 560 -* **AT+ADDMOD6=1** **~-~->** Enable trigger 591 +* **AT+MOD=1 ** **~-~->** The normal working mode 592 +* **AT+ADDMOD6=1** **~-~->** Enable trigger 561 561 562 562 LT will keep monitoring AV1/AV2/AC1/AC2 every 5 seconds; LT will send uplink packets in two cases: 563 563 ... ... @@ -564,9 +564,9 @@ 564 564 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 565 565 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 566 566 567 - 568 568 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 569 569 601 + 570 570 (% style="color:#4f81bd" %)**Trigger base on voltage**: 571 571 572 572 Format: AT+AVLIM=<AV1_LIMIT_LOW>,< AV1_LIMIT_HIGH>,<AV2_LIMIT_LOW>,< AV2_LIMIT_HIGH> ... ... @@ -696,6 +696,7 @@ 696 696 697 697 == 3.4 Configure LT via AT or Downlink == 698 698 731 + 699 699 User can configure LT I/O Controller via AT Commands or LoRaWAN Downlink Commands 700 700 701 701 ((( ... ... @@ -706,8 +706,12 @@ 706 706 707 707 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 708 708 742 + 743 + 744 + 709 709 === 3.4.1 Common Commands === 710 710 747 + 711 711 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] 712 712 713 713 ... ... @@ -714,8 +714,10 @@ 714 714 715 715 === 3.4.2 Sensor related commands === 716 716 754 + 717 717 ==== 3.4.2.1 Set Transmit Interval ==== 718 718 757 + 719 719 Set device uplink interval. 720 720 721 721 * (% style="color:#037691" %)**AT Command:** ... ... @@ -735,6 +735,7 @@ 735 735 736 736 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 737 737 777 + 738 738 Set work mode. 739 739 740 740 * (% style="color:#037691" %)**AT Command:** ... ... @@ -754,6 +754,7 @@ 754 754 755 755 ==== 3.4.2.3 Poll an uplink ==== 756 756 797 + 757 757 * (% style="color:#037691" %)**AT Command:** 758 758 759 759 There is no AT Command to poll uplink ... ... @@ -767,8 +767,10 @@ 767 767 768 768 769 769 811 + 770 770 ==== 3.4.2.4 Enable Trigger Mode ==== 771 771 814 + 772 772 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 773 773 774 774 * (% style="color:#037691" %)**AT Command:** ... ... @@ -789,6 +789,7 @@ 789 789 790 790 ==== 3.4.2.5 Poll trigger settings ==== 791 791 835 + 792 792 Poll trigger settings, 793 793 794 794 * (% style="color:#037691" %)**AT Command:** ... ... @@ -798,7 +798,7 @@ 798 798 799 799 * (% style="color:#037691" %)**Downlink Payload (prefix 0x AB 06):** 800 800 801 -**0xAB 06 845 +**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 802 802 803 803 804 804 ... ... @@ -805,6 +805,7 @@ 805 805 806 806 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 807 807 852 + 808 808 Enable Disable DI1/DI2/DI2 as trigger, 809 809 810 810 * (% style="color:#037691" %)**AT Command:** ... ... @@ -825,6 +825,7 @@ 825 825 826 826 ==== 3.4.2.7 Trigger1 – Set DI1 or DI3 as trigger ==== 827 827 873 + 828 828 Set DI1 or DI3(for LT-33222-L) trigger. 829 829 830 830 * (% style="color:#037691" %)**AT Command:** ... ... @@ -849,6 +849,7 @@ 849 849 850 850 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 851 851 898 + 852 852 Set DI2 trigger. 853 853 854 854 * (% style="color:#037691" %)**AT Command:** ... ... @@ -875,6 +875,7 @@ 875 875 876 876 ==== 3.4.2.9 Trigger – Set AC (current) as trigger ==== 877 877 925 + 878 878 Set current trigger , base on AC port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 879 879 880 880 * (% style="color:#037691" %)**AT Command** ... ... @@ -891,6 +891,7 @@ 891 891 892 892 ==== 3.4.2.10 Trigger – Set AV (voltage) as trigger ==== 893 893 942 + 894 894 Set current trigger , base on AV port. See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 895 895 896 896 * (% style="color:#037691" %)**AT Command** ... ... @@ -907,11 +907,12 @@ 907 907 908 908 ==== 3.4.2.11 Trigger – Set minimum interval ==== 909 909 959 + 910 910 Set AV and AC trigger minimum interval, system won't response to the second trigger within this set time after the first trigger. 911 911 912 912 * (% style="color:#037691" %)**AT Command** 913 913 914 -**AT+ATDC=5 964 +**AT+ATDC=5 ** Device won't response the second trigger within 5 minute after the first trigger. 915 915 916 916 917 917 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -918,11 +918,18 @@ 918 918 919 919 **0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 920 920 971 +((( 972 + 921 921 974 +(% style="color:red" %)Note: ATDC setting must be more than 5min 975 +))) 922 922 923 923 978 + 979 + 924 924 ==== 3.4.2.12 DO ~-~- Control Digital Output DO1/DO2/DO3 ==== 925 925 982 + 926 926 * (% style="color:#037691" %)**AT Command** 927 927 928 928 There is no AT Command to control Digital Output ... ... @@ -954,6 +954,7 @@ 954 954 955 955 ==== 3.4.2.13 DO ~-~- Control Digital Output DO1/DO2/DO3 with time control ==== 956 956 1014 + 957 957 * (% style="color:#037691" %)**AT Command** 958 958 959 959 There is no AT Command to control Digital Output ... ... @@ -1020,6 +1020,7 @@ 1020 1020 1021 1021 ==== 3.4.2.14 Relay ~-~- Control Relay Output RO1/RO2 ==== 1022 1022 1081 + 1023 1023 * (% style="color:#037691" %)**AT Command:** 1024 1024 1025 1025 There is no AT Command to control Relay Output ... ... @@ -1049,6 +1049,7 @@ 1049 1049 1050 1050 ==== 3.4.2.15 Relay ~-~- Control Relay Output RO1/RO2 with time control ==== 1051 1051 1111 + 1052 1052 * (% style="color:#037691" %)**AT Command:** 1053 1053 1054 1054 There is no AT Command to control Relay Output ... ... @@ -1072,7 +1072,7 @@ 1072 1072 1073 1073 (% style="color:#4f81bd" %)**Third Byte(bb)**(%%): Control Method and Ports status: 1074 1074 1075 -[[image:image-20220 524093831-10.png]]1135 +[[image:image-20220714135731-1.png||height="406" width="627"]] 1076 1076 1077 1077 1078 1078 (% style="color:#4f81bd" %)**Fourth/Fifth Bytes(cc)**(%%): Latching time. Unit: ms ... ... @@ -1082,21 +1082,21 @@ 1082 1082 1083 1083 **Example payload:** 1084 1084 1085 -**~1. 05 01 11 07 D 0**1145 +**~1. 05 01 11 07 D** 1086 1086 1087 -Relay1 and Relay 2 will be set to N O, last 2 seconds, then change back to original state.1147 +Relay1 and Relay 2 will be set to NC , last 2 seconds, then change back to original state. 1088 1088 1089 1089 **2. 05 01 10 07 D0** 1090 1090 1091 -Relay1 will change to N O, Relay2 will change to NC, last 2 seconds, then both change back to original state.1151 +Relay1 will change to NC, Relay2 will change to NO, last 2 seconds, then both change back to original state. 1092 1092 1093 1093 **3. 05 00 01 07 D0** 1094 1094 1095 -Relay1 will change to N C, Relay2 will change to NO, last 2 seconds, then relay change to NO,C.1155 +Relay1 will change to NO, Relay2 will change to NC, last 2 seconds, then relay change to NC,Relay2 change to NO. 1096 1096 1097 1097 **4. 05 00 00 07 D0** 1098 1098 1099 -Relay 1 & relay2 will change to N C, last 2 seconds, then both change to NO.1159 +Relay 1 & relay2 will change to NO, last 2 seconds, then both change to NC. 1100 1100 1101 1101 1102 1102 ... ... @@ -1103,6 +1103,7 @@ 1103 1103 1104 1104 ==== 3.4.2.16 Counting ~-~- Voltage threshold counting ==== 1105 1105 1166 + 1106 1106 When voltage exceed the threshold, count. Feature see [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1107 1107 1108 1108 * (% style="color:#037691" %)**AT Command:** ... ... @@ -1119,6 +1119,7 @@ 1119 1119 1120 1120 ==== 3.4.2.17 Counting ~-~- Pre-configure the Count Number ==== 1121 1121 1183 + 1122 1122 * (% style="color:#037691" %)**AT Command:** 1123 1123 1124 1124 **AT+SETCNT=aa,(bb cc dd ee) ** ... ... @@ -1141,11 +1141,12 @@ 1141 1141 1142 1142 ==== 3.4.2.18 Counting ~-~- Clear Counting ==== 1143 1143 1206 + 1144 1144 Clear counting for counting mode 1145 1145 1146 1146 * (% style="color:#037691" %)**AT Command:** 1147 1147 1148 - (% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting1211 +**AT+CLRCOUNT ** ~/~/ clear all counting 1149 1149 1150 1150 1151 1151 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1157,6 +1157,7 @@ 1157 1157 1158 1158 ==== 3.4.2.19 Counting ~-~- Change counting mode save time ==== 1159 1159 1223 + 1160 1160 * (% style="color:#037691" %)**AT Command:** 1161 1161 1162 1162 **AT+COUTIME=60 **~/~/ Set save time to 60 seconds. Device will save the counting result in internal flash every 60 seconds. (min value: 30) ... ... @@ -1176,6 +1176,7 @@ 1176 1176 1177 1177 == 3.5 Integrate with Mydevice == 1178 1178 1243 + 1179 1179 Mydevices provides a human friendly interface to show the sensor data, once we have data in TTN, we can use Mydevices to connect to TTN and see the data in Mydevices. Below are the steps: 1180 1180 1181 1181 ((( ... ... @@ -1184,14 +1184,15 @@ 1184 1184 1185 1185 ((( 1186 1186 (% style="color:blue" %)**Step 2**(%%): To configure the Application to forward data to Mydevices you will need to add integration. To add the Mydevices integration, perform the following steps: 1252 + 1253 + 1187 1187 ))) 1188 1188 1189 -[[image:1 653356737703-362.png||height="232" width="732"]]1256 +[[image:image-20220719105525-1.png||height="377" width="677"]] 1190 1190 1191 -[[image:image-20220524094641-11.png||height="390" width="723"]] 1192 1192 1193 1193 1194 -[[image:image-20220 524094641-12.png||height="402" width="718"]]1260 +[[image:image-20220719110247-2.png||height="388" width="683"]] 1195 1195 1196 1196 1197 1197 (% style="color:blue" %)**Step 3**(%%): Create an account or log in Mydevices. ... ... @@ -1224,8 +1224,10 @@ 1224 1224 1225 1225 == 3.6 Interface Detail == 1226 1226 1293 + 1227 1227 === 3.6.1 Digital Input Port: DI1/DI2 /DI3 ( For LT-33222-L, low active ) === 1228 1228 1296 + 1229 1229 Support NPN Type sensor 1230 1230 1231 1231 [[image:1653356991268-289.png]] ... ... @@ -1234,6 +1234,7 @@ 1234 1234 1235 1235 === 3.6.2 Digital Input Port: DI1/DI2 ( For LT-22222-L) === 1236 1236 1305 + 1237 1237 ((( 1238 1238 The DI port of LT-22222-L can support NPN or PNP output sensor. 1239 1239 ))) ... ... @@ -1240,7 +1240,9 @@ 1240 1240 1241 1241 ((( 1242 1242 ((( 1243 -Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high 1312 +Internal circuit as below, the NEC2501 is a photocoupler, the Active current (from NEC2501 pin 1 to pin 2 is 1ma and the max current is 50mA. When there is active current pass NEC2501 pin1 to pin2. The DI will be active high. 1313 + 1314 + 1244 1244 ))) 1245 1245 ))) 1246 1246 ... ... @@ -1285,6 +1285,8 @@ 1285 1285 1286 1286 ((( 1287 1287 1359 + 1360 + 1288 1288 ))) 1289 1289 1290 1290 ((( ... ... @@ -1316,6 +1316,8 @@ 1316 1316 1317 1317 ((( 1318 1318 1392 + 1393 + 1319 1319 ))) 1320 1320 1321 1321 ((( ... ... @@ -1349,6 +1349,7 @@ 1349 1349 1350 1350 === 3.6.3 Digital Output Port: DO1/DO2 /DO3 === 1351 1351 1427 + 1352 1352 NPN output: GND or Float. Max voltage can apply to output pin is 36v. 1353 1353 1354 1354 [[image:1653357531600-905.png]] ... ... @@ -1357,6 +1357,7 @@ 1357 1357 1358 1358 === 3.6.4 Analog Input Interface === 1359 1359 1436 + 1360 1360 The analog input interface is as below. The LT will measure the IN2 voltage so to calculate the current pass the Load. The formula is: 1361 1361 1362 1362 ... ... @@ -1388,6 +1388,7 @@ 1388 1388 1389 1389 === 3.6.5 Relay Output === 1390 1390 1468 + 1391 1391 ((( 1392 1392 The LT serial controller has two relay interfaces; each interface uses two pins of the screw terminal. User can connect other device’s Power Line to in serial of RO1_1 and RO_2. Such as below: 1393 1393 ))) ... ... @@ -1400,6 +1400,7 @@ 1400 1400 1401 1401 == 3.7 LEDs Indicators == 1402 1402 1481 + 1403 1403 [[image:image-20220524100748-11.png]] 1404 1404 1405 1405 ... ... @@ -1406,8 +1406,10 @@ 1406 1406 1407 1407 = 4. Use AT Command = 1408 1408 1488 + 1409 1409 == 4.1 Access AT Command == 1410 1410 1491 + 1411 1411 LT supports AT Command set. User can use a USB to TTL adapter plus the 3.5mm Program Cable to connect to LT for using AT command, as below. 1412 1412 1413 1413 [[image:1653358238933-385.png]] ... ... @@ -1612,6 +1612,7 @@ 1612 1612 1613 1613 == 4.2 Common AT Command Sequence == 1614 1614 1696 + 1615 1615 === 4.2.1 Multi-channel ABP mode (Use with SX1301/LG308) === 1616 1616 1617 1617 ((( ... ... @@ -1735,13 +1735,16 @@ 1735 1735 1736 1736 === 4.2.3 Change to Class A === 1737 1737 1820 + 1738 1738 If sensor JOINED 1739 1739 (% style="background-color:#dcdcdc" %)AT+CLASS=A 1740 1740 ATZ 1741 1741 1742 1742 1826 + 1743 1743 = 5. FAQ = 1744 1744 1829 + 1745 1745 == 5.1 How to upgrade the image? == 1746 1746 1747 1747 ... ... @@ -1763,7 +1763,9 @@ 1763 1763 1764 1764 1765 1765 (% style="color:blue" %)**For LT-22222-L**(%%): 1766 -Hold down the PRO button and then momentarily press the RST reset button and the **DO1 led** will change from OFF to ON. When **DO1 LED** is on, it means the device is in download mode. 1851 +Hold down the PRO button and then momentarily press the RST reset button and the (% style="color:red" %)**DO1 led**(%%) will change from OFF to ON. When (% style="color:red" %)**DO1 LED**(%%) is on, it means the device is in download mode. 1852 + 1853 + 1767 1767 ))) 1768 1768 1769 1769 [[image:image-20220524103407-12.png]] ... ... @@ -1775,6 +1775,7 @@ 1775 1775 1776 1776 (% style="color:red" %)**Notice**(%%): In case user has lost the program cable. User can hand made one from a 3.5mm cable. The pin mapping is: 1777 1777 1865 + 1778 1778 [[image:1653360054704-518.png||height="186" width="745"]] 1779 1779 1780 1780 ... ... @@ -1783,6 +1783,8 @@ 1783 1783 1784 1784 1785 1785 == 5.2 How to change the LoRa Frequency Bands/Region? == 1874 + 1875 + 1786 1786 ))) 1787 1787 ))) 1788 1788 ... ... @@ -1793,7 +1793,10 @@ 1793 1793 ((( 1794 1794 1795 1795 1886 + 1796 1796 == 5.3 How to set up LT to work with Single Channel Gateway such as LG01/LG02? == 1888 + 1889 + 1797 1797 ))) 1798 1798 1799 1799 ((( ... ... @@ -1811,7 +1811,7 @@ 1811 1811 ))) 1812 1812 1813 1813 ((( 1814 -(% style="color: #4f81bd" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device.1907 +(% style="color:blue" %)**Step1**(%%): Log in TTN, Create an ABP device in the application and input the network session key (NETSKEY), app session key (APPSKEY) from the device. 1815 1815 ))) 1816 1816 1817 1817 ((( ... ... @@ -1819,12 +1819,12 @@ 1819 1819 ))) 1820 1820 1821 1821 ((( 1822 -(% style="color:red" %)Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN. 1915 +(% style="color:red" %)**Note: user just need to make sure above three keys match, User can change either in TTN or Device to make then match. In TTN, NETSKEY and APPSKEY can be configured by user in setting page, but Device Addr is generated by TTN.** 1823 1823 ))) 1824 1824 1825 1825 1826 1826 ((( 1827 -(% style="color: #4f81bd" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands:1920 +(% style="color:blue" %)**Step2**(%%)**: **Run AT Command to make LT work in Single frequency & ABP mode. Below is the AT commands: 1828 1828 ))) 1829 1829 1830 1830 ((( ... ... @@ -1848,16 +1848,21 @@ 1848 1848 [[image:1653360498588-932.png||height="485" width="726"]] 1849 1849 1850 1850 1944 + 1851 1851 == 5.4 Can I see counting event in Serial? == 1852 1852 1947 + 1853 1853 ((( 1854 -User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn ’t support AT+DEBUG. User can update to latest firmware first.1949 +User can run AT+DEBUG command to see the counting event in serial. If firmware too old and doesn't support AT+DEBUG. User can update to latest firmware first. 1855 1855 1856 1856 1952 + 1857 1857 == 5.5 Can i use point to point communication for LT-22222-L? == 1858 1858 1955 + 1859 1859 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1860 1860 1958 + 1861 1861 1862 1862 ))) 1863 1863 ... ... @@ -1864,6 +1864,7 @@ 1864 1864 ((( 1865 1865 == 5.6 Why does the relay output become the default and open relay after the lt22222 is powered off? == 1866 1866 1965 + 1867 1867 If the device is not shut down, but directly powered off. 1868 1868 1869 1869 It will default that this is a power-off state. ... ... @@ -1873,12 +1873,15 @@ 1873 1873 After restart, the status before power failure will be read from flash. 1874 1874 1875 1875 1975 + 1876 1876 = 6. Trouble Shooting = 1877 1877 ))) 1878 1878 1879 1879 ((( 1880 1880 ((( 1881 -== 6.1 Downlink doesn’t work, how to solve it? == 1981 +== 6.1 Downlink doesn't work, how to solve it? == 1982 + 1983 + 1882 1882 ))) 1883 1883 ))) 1884 1884 ... ... @@ -1889,7 +1889,10 @@ 1889 1889 ((( 1890 1890 1891 1891 1994 + 1892 1892 == 6.2 Have trouble to upload image. == 1996 + 1997 + 1893 1893 ))) 1894 1894 1895 1895 ((( ... ... @@ -1899,7 +1899,10 @@ 1899 1899 ((( 1900 1900 1901 1901 1902 -== 6.3 Why I can’t join TTN in US915 /AU915 bands? == 2007 + 2008 +== 6.3 Why I can't join TTN in US915 /AU915 bands? == 2009 + 2010 + 1903 1903 ))) 1904 1904 1905 1905 ((( ... ... @@ -1913,22 +1913,22 @@ 1913 1913 1914 1914 (% style="color:#4f81bd" %)**LT-22222-L-XXX:** 1915 1915 1916 - 1917 1917 (% style="color:#4f81bd" %)**XXX:** 1918 1918 1919 -* (% style="color: #4f81bd" %)**EU433**(%%): LT with frequency bands EU4331920 -* (% style="color: #4f81bd" %)**EU868**(%%): LT with frequency bands EU8681921 -* (% style="color: #4f81bd" %)**KR920**(%%): LT with frequency bands KR9201922 -* (% style="color: #4f81bd" %)**CN470**(%%): LT with frequency bands CN4701923 -* (% style="color: #4f81bd" %)**AS923**(%%): LT with frequency bands AS9231924 -* (% style="color: #4f81bd" %)**AU915**(%%): LT with frequency bands AU9151925 -* (% style="color: #4f81bd" %)**US915**(%%): LT with frequency bands US9151926 -* (% style="color: #4f81bd" %)**IN865**(%%): LT with frequency bands IN8651927 -* (% style="color: #4f81bd" %)**CN779**(%%): LT with frequency bands CN7792026 +* (% style="color:red" %)**EU433**(%%): LT with frequency bands EU433 2027 +* (% style="color:red" %)**EU868**(%%): LT with frequency bands EU868 2028 +* (% style="color:red" %)**KR920**(%%): LT with frequency bands KR920 2029 +* (% style="color:red" %)**CN470**(%%): LT with frequency bands CN470 2030 +* (% style="color:red" %)**AS923**(%%): LT with frequency bands AS923 2031 +* (% style="color:red" %)**AU915**(%%): LT with frequency bands AU915 2032 +* (% style="color:red" %)**US915**(%%): LT with frequency bands US915 2033 +* (% style="color:red" %)**IN865**(%%): LT with frequency bands IN865 2034 +* (% style="color:red" %)**CN779**(%%): LT with frequency bands CN779 1928 1928 1929 1929 1930 1930 1931 1931 2039 + 1932 1932 = 8. Packing Info = 1933 1933 1934 1934 ... ... @@ -1949,8 +1949,10 @@ 1949 1949 1950 1950 1951 1951 2060 + 1952 1952 = 9. Support = 1953 1953 2063 + 1954 1954 * ((( 1955 1955 Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1956 1956 ))) ... ... @@ -1959,12 +1959,16 @@ 1959 1959 1960 1960 1961 1961 2072 + 1962 1962 1963 1963 ))) 1964 1964 1965 1965 = 10. Reference = 1966 1966 2078 + 1967 1967 * LT-22222-L: [[http:~~/~~/www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html>>url:http://www.dragino.com/products/lora-lorawan-end-node/item/156-lt-22222-l.html]] 1968 -* [[Image Download>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/image/]] 1969 -* [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LT_LoRa_IO_Controller/LT33222-L/]] 2080 +* [[Datasheet, Document Base>>https://www.dropbox.com/sh/gxxmgks42tqfr3a/AACEdsj_mqzeoTOXARRlwYZ2a?dl=0]] 1970 1970 * [[Hardware Source>>url:https://github.com/dragino/Lora/tree/master/LT/LT-33222-L/v1.0]] 2082 + 2083 + 2084 +
- image-20220714135731-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.1 KB - Content
- image-20220719105525-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +165.5 KB - Content
- image-20220719110247-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Bei - Size
-
... ... @@ -1,0 +1,1 @@ 1 +52.9 KB - Content