Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Mengting Qiu on 2025/06/04 18:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -181,6 +181,7 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 + 184 184 == 1.4 Applications == 185 185 186 186 * Smart Buildings & Home Automation ... ... @@ -190,6 +190,7 @@ 190 190 * Smart Cities 191 191 * Smart Factory 192 192 194 + 193 193 == 1.5 Hardware Variants == 194 194 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -205,6 +205,7 @@ 205 205 206 206 207 207 210 + 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -285,6 +285,7 @@ 285 285 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 286 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 291 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -338,6 +338,7 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 345 + 341 341 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 342 342 343 343 ... ... @@ -389,17 +389,17 @@ 389 389 **For LT22222-L:** 390 390 391 391 392 - (% style="color:blue" %)**AT+TRIG1=0,100**(%%)**(set DI1 port to trigger on low level, valid signal is 100ms) **397 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 393 393 394 - (% style="color:blue" %)**AT+TRIG1=1,100**(%%)**(set DI1 port to trigger on high level, valid signal is 100ms ) **399 +**AT+TRIG1=1,100 (set DI1 port to trigger on high level, valid signal is 100ms ) ** 395 395 396 - (% style="color:blue" %)**AT+TRIG2=0,100**(%%)**(set DI2 port to trigger on low level, valid signal is 100ms) **401 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 397 397 398 - (% style="color:blue" %)**AT+TRIG2=1,100**(%%)**(set DI2 port to trigger on high level, valid signal is 100ms ) **403 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 399 399 400 - (% style="color:blue" %)**AT+SETCNT=1,60**(%%)**(Set COUNT1 value to 60)**405 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 401 401 402 - (% style="color:blue" %)**AT+SETCNT=2,60**(%%)**(Set COUNT2 value to 60)**407 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 403 403 ))) 404 404 405 405 ... ... @@ -706,6 +706,7 @@ 706 706 707 707 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 708 708 714 + 709 709 === 3.4.1 Common Commands === 710 710 711 711 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -720,19 +720,23 @@ 720 720 721 721 * (% style="color:#037691" %)**AT Command:** 722 722 729 +(% class="box infomessage" %) 730 +((( 723 723 **AT+TDC=N ** 732 +))) 724 724 725 - 726 726 **Example: **AT+TDC=30000. Means set interval to 30 seconds 727 727 728 728 729 729 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 730 730 739 +(% class="box infomessage" %) 740 +((( 731 731 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 742 +))) 732 732 733 733 734 734 735 - 736 736 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 737 737 738 738 Set work mode. ... ... @@ -739,29 +739,36 @@ 739 739 740 740 * (% style="color:#037691" %)**AT Command:** 741 741 752 +(% class="box infomessage" %) 753 +((( 742 742 **AT+MOD=N ** 755 +))) 743 743 744 - 745 745 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 746 746 747 747 748 748 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 749 749 750 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 762 +(% class="box infomessage" %) 763 +((( 764 +**0x0A aa ~/~/ Same as AT+MOD=aa** 765 +))) 751 751 752 752 753 753 754 - 755 755 ==== 3.4.2.3 Poll an uplink ==== 756 756 757 -* (% style="color:#037691" %) **AT Command:**771 +* (% style="color:#037691" %)AT Command: 758 758 759 759 There is no AT Command to poll uplink 760 760 761 761 762 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x08):**776 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 763 763 764 -**0x08 FF **~/~/ Poll an uplink 778 +(% class="box infomessage" %) 779 +((( 780 +**0x08 FF ~/~/ Poll an uplink,** 781 +))) 765 765 766 766 **Example**: 0x08FF, ask device to send an Uplink 767 767 ... ... @@ -771,9 +771,12 @@ 771 771 772 772 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 773 773 774 -* (% style="color:#037691" %) **AT Command:**791 +* (% style="color:#037691" %)AT Command: 775 775 793 +(% class="box infomessage" %) 794 +((( 776 776 **AT+ADDMOD6=1 or 0** 796 +))) 777 777 778 778 1: Enable Trigger Mode 779 779 ... ... @@ -780,34 +780,38 @@ 780 780 0: Disable Trigger Mode 781 781 782 782 783 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x0A 06):**803 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 784 784 785 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 805 +(% class="box infomessage" %) 806 +((( 807 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 808 +))) 786 786 787 787 788 788 789 - 790 790 ==== 3.4.2.5 Poll trigger settings ==== 791 791 792 792 Poll trigger settings, 793 793 794 -* (% style="color:#037691" %) **AT Command:**816 +* (% style="color:#037691" %)AT Command: 795 795 796 796 There is no AT Command for this feature. 797 797 798 798 799 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**821 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 800 800 801 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 823 +(% class="box infomessage" %) 824 +((( 825 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 826 +))) 802 802 803 803 804 804 805 - 806 806 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 807 807 808 808 Enable Disable DI1/DI2/DI2 as trigger, 809 809 810 -* (% style="color:#037691" %) **AT Command:**834 +* (% style="color:#037691" %)AT Command: 811 811 812 812 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 813 813 ... ... @@ -816,7 +816,7 @@ 816 816 817 817 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 818 818 819 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**843 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 820 820 821 821 **0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 822 822 ... ... @@ -827,7 +827,7 @@ 827 827 828 828 Set DI1 or DI3(for LT-33222-L) trigger. 829 829 830 -* (% style="color:#037691" %) **AT Command:**854 +* (% style="color:#037691" %)AT Command: 831 831 832 832 **AT+TRIG1=a,b** 833 833 ... ... @@ -846,7 +846,6 @@ 846 846 847 847 848 848 849 - 850 850 ==== 3.4.2.8 Trigger2 – Set DI2 as trigger ==== 851 851 852 852 Set DI2 trigger. ... ... @@ -907,11 +907,11 @@ 907 907 908 908 ==== 3.4.2.11 Trigger – Set minimum interval ==== 909 909 910 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.933 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 911 911 912 912 * (% style="color:#037691" %)**AT Command** 913 913 914 -**AT+ATDC=5 **Device won't response the second trigger within 5 minute after the first trigger.937 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 915 915 916 916 917 917 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** ... ... @@ -1121,7 +1121,7 @@ 1121 1121 1122 1122 * (% style="color:#037691" %)**AT Command:** 1123 1123 1124 -**AT+SETCNT=aa,(bb cc dd ee) ** 1147 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1125 1125 1126 1126 aa: 1: Set count1, 1127 1127 ... ... @@ -1145,7 +1145,7 @@ 1145 1145 1146 1146 * (% style="color:#037691" %)**AT Command:** 1147 1147 1148 -(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1171 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1149 1149 1150 1150 1151 1151 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):** ... ... @@ -1403,7 +1403,6 @@ 1403 1403 [[image:image-20220524100748-11.png]] 1404 1404 1405 1405 1406 - 1407 1407 = 4. Use AT Command = 1408 1408 1409 1409 == 4.1 Access AT Command == ... ... @@ -1606,6 +1606,8 @@ 1606 1606 1607 1607 ((( 1608 1608 AT+CFG: Print all settings 1631 + 1632 + 1609 1609 ))) 1610 1610 1611 1611 ... ... @@ -1651,6 +1651,8 @@ 1651 1651 1652 1652 ((( 1653 1653 (% style="background-color:#dcdcdc" %)ATZ 1678 + 1679 + 1654 1654 ))) 1655 1655 1656 1656 ... ... @@ -1857,8 +1857,6 @@ 1857 1857 == 5.5 Can i use point to point communication for LT-22222-L? == 1858 1858 1859 1859 Yes, please refer [[Point to Point Communication>>doc:Main. Point to Point Communication of LT-22222-L.WebHome]] 1860 - 1861 - 1862 1862 ))) 1863 1863 1864 1864 ((( ... ... @@ -1872,7 +1872,6 @@ 1872 1872 1873 1873 After restart, the status before power failure will be read from flash. 1874 1874 1875 - 1876 1876 = 6. Trouble Shooting = 1877 1877 ))) 1878 1878 ... ... @@ -1926,9 +1926,6 @@ 1926 1926 * (% style="color:#4f81bd" %)**IN865**(%%): LT with frequency bands IN865 1927 1927 * (% style="color:#4f81bd" %)**CN779**(%%): LT with frequency bands CN779 1928 1928 1929 - 1930 - 1931 - 1932 1932 = 8. Packing Info = 1933 1933 1934 1934 ... ... @@ -1946,9 +1946,6 @@ 1946 1946 * Package Size / pcs : 14.5 x 8 x 5 cm 1947 1947 * Weight / pcs : 170g 1948 1948 1949 - 1950 - 1951 - 1952 1952 = 9. Support = 1953 1953 1954 1954 * ((( ... ... @@ -1956,10 +1956,6 @@ 1956 1956 ))) 1957 1957 * ((( 1958 1958 Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:file:///D:/市场资料/说明书/LoRa/LT系列/support@dragino.com]] 1959 - 1960 - 1961 - 1962 - 1963 1963 ))) 1964 1964 1965 1965 = 10. Reference =