Changes for page LT-22222-L -- LoRa I/O Controller User Manual
Last modified by Saxer Lin on 2025/04/15 17:24
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -181,6 +181,8 @@ 181 181 * Firmware upgradable via program port 182 182 * Counting 183 183 184 + 185 + 184 184 == 1.4 Applications == 185 185 186 186 * Smart Buildings & Home Automation ... ... @@ -190,6 +190,8 @@ 190 190 * Smart Cities 191 191 * Smart Factory 192 192 195 + 196 + 193 193 == 1.5 Hardware Variants == 194 194 195 195 (% border="1" style="background-color:#f7faff; width:500px" %) ... ... @@ -204,7 +204,6 @@ 204 204 ))) 205 205 206 206 207 - 208 208 = 2. Power ON Device = 209 209 210 210 The LT controller can be powered by 7 ~~ 24V DC power source. Connect VIN to Power Input V+ and GND to power input V- to power the LT controller. ... ... @@ -285,6 +285,8 @@ 285 285 * **MOD5**: Single DI Counting + 2 x AVI + 1 x ACI + DO + RO 286 286 * **ADDMOD6**: Trigger Mode, Optional, used together with MOD1 ~~ MOD5 287 287 291 + 292 + 288 288 === 3.3.1 AT+MOD~=1, 2ACI+2AVI === 289 289 290 290 The uplink payload includes totally 9 bytes. Uplink packets use FPORT=2 and every 10 minutes send one uplink by default. ... ... @@ -338,6 +338,8 @@ 338 338 ** DO1 is high in case there is load between DO1 and V+. 339 339 ** DO1 LED is off in both case 340 340 346 + 347 + 341 341 === 3.3.2 AT+MOD~=2, (Double DI Counting) === 342 342 343 343 ... ... @@ -387,20 +387,24 @@ 387 387 388 388 ((( 389 389 **For LT22222-L:** 397 +))) 390 390 399 +(% class="box infomessage" %) 400 +((( 401 +((( 402 +**AT+TRIG1=0,100 (set DI1 port to trigger on low level, valid signal is 100ms) ** 391 391 392 - (% style="color:blue" %)**AT+TRIG1=0,100**(%%)** (set DI1 port to trigger onlowlevel, valid signal is 100ms) **404 +**AT+TRIG1=1,100(set DI1 port to trigger on high level, valid signal is 100ms ) ** 393 393 394 - (% style="color:blue" %)**AT+TRIG1=1,100**(%%)**1port to trigger onhighlevel, valid signal is 100ms406 +**AT+TRIG2=0,100 (set DI2 port to trigger on low level, valid signal is 100ms) ** 395 395 396 - (% style="color:blue" %)**AT+TRIG2=0,100**(%%)**lowlevel, valid signal is 100ms) **408 +**AT+TRIG2=1,100 (set DI2 port to trigger on high level, valid signal is 100ms ) ** 397 397 398 - (% style="color:blue" %)**AT+TRIG2=1,100**(%%)**setDI2port to trigger on high level, validsignalis 100ms)410 +**AT+SETCNT=1,60 (Set COUNT1 value to 60)** 399 399 400 -(% style="color:blue" %)**AT+SETCNT=1,60**(%%)** (Set COUNT1 value to 60)** 401 - 402 -(% style="color:blue" %)**AT+SETCNT=2,60**(%%)** (Set COUNT2 value to 60)** 412 +**AT+SETCNT=2,60 (Set COUNT2 value to 60)** 403 403 ))) 414 +))) 404 404 405 405 406 406 ... ... @@ -492,19 +492,22 @@ 492 492 493 493 494 494 **Plus below command for AVI1 Counting:** 506 +))) 495 495 508 +(% class="box infomessage" %) 509 +((( 510 +((( 511 +(% style="color:blue" %)**AT+SETCNT=3,60**(%%)** (set AVI Count to 60)** 496 496 497 -(% style="color:blue" %)**AT+ SETCNT=3,60**(%%)**(set AVICountto60)**513 +(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** (If AVI1 voltage higher than VOLMAX (20000mV =20v), counter increase 1)** 498 498 499 -(% style="color:blue" %)**AT+VOLMAX=20000**(%%)** higher than VOLMAX (20000mV =20v), counter increase 1)**515 +(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 500 500 501 -(% style="color:blue" %)**AT+VOLMAX=20000,0**(%%)** (If AVI1 voltage lower than VOLMAX (20000mV =20v), counter increase 1)** 502 - 503 -(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 517 +(% style="color:blue" %)**AT+VOLMAX=20000,1**(%%)** (If AVI1 voltage higer than VOLMAX (20000mV =20v), counter increase 1)** 504 504 ))) 519 +))) 505 505 506 506 507 - 508 508 === 3.3.5 AT+MOD~=5, Single DI Counting + 2 x AVI + 1 x ACI === 509 509 510 510 ... ... @@ -564,7 +564,6 @@ 564 564 1. Periodically uplink (Base on TDC time). Payload is same as the normal MOD (MOD 1 for above command). This uplink uses LoRaWAN (% style="color:#4f81bd" %)**unconfirmed**(%%) data type 565 565 1. Trigger uplink when meet the trigger condition. LT will sent two packets in this case, the first uplink use payload specify in this mod (mod=6), the second packets use the normal mod payload(MOD=1 for above settings). Both Uplinks use LoRaWAN (% style="color:#4f81bd" %)**CONFIRMED data type.** 566 566 567 - 568 568 (% style="color:#037691" %)**AT Command to set Trigger Condition**: 569 569 570 570 (% style="color:#4f81bd" %)**Trigger base on voltage**: ... ... @@ -706,6 +706,8 @@ 706 706 707 707 * (% style="color:#4f81bd" %)**Sensor Related Commands**(%%): These commands are special designed for LT-22222-L. User can see these commands below: 708 708 722 + 723 + 709 709 === 3.4.1 Common Commands === 710 710 711 711 They should be available for each of Dragino Sensors, such as: change uplink interval, reset device. For firmware v1.5.4, user can find what common commands it supports: [[End Device AT Commands and Downlink Command>>doc:Main.End Device AT Commands and Downlink Command.WebHome]] ... ... @@ -720,19 +720,23 @@ 720 720 721 721 * (% style="color:#037691" %)**AT Command:** 722 722 738 +(% class="box infomessage" %) 739 +((( 723 723 **AT+TDC=N ** 741 +))) 724 724 725 - 726 726 **Example: **AT+TDC=30000. Means set interval to 30 seconds 727 727 728 728 729 729 * (% style="color:#037691" %)**Downlink Payload (prefix 0x01):** 730 730 748 +(% class="box infomessage" %) 749 +((( 731 731 **0x01 aa bb cc ~/~/ Same as AT+TDC=0x(aa bb cc)** 751 +))) 732 732 733 733 734 734 735 - 736 736 ==== 3.4.2.2 Set Work Mode (AT+MOD) ==== 737 737 738 738 Set work mode. ... ... @@ -739,29 +739,36 @@ 739 739 740 740 * (% style="color:#037691" %)**AT Command:** 741 741 761 +(% class="box infomessage" %) 762 +((( 742 742 **AT+MOD=N ** 764 +))) 743 743 744 - 745 745 **Example**: AT+MOD=2. Set work mode to Double DI counting mode 746 746 747 747 748 748 * (% style="color:#037691" %)**Downlink Payload (prefix 0x0A):** 749 749 750 -**0x0A aa ** ~/~/ Same as AT+MOD=aa 771 +(% class="box infomessage" %) 772 +((( 773 +**0x0A aa ~/~/ Same as AT+MOD=aa** 774 +))) 751 751 752 752 753 753 754 - 755 755 ==== 3.4.2.3 Poll an uplink ==== 756 756 757 -* (% style="color:#037691" %) **AT Command:**780 +* (% style="color:#037691" %)AT Command: 758 758 759 759 There is no AT Command to poll uplink 760 760 761 761 762 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x08):**785 +* (% style="color:#037691" %)Downlink Payload (prefix 0x08): 763 763 764 -**0x08 FF **~/~/ Poll an uplink 787 +(% class="box infomessage" %) 788 +((( 789 +**0x08 FF ~/~/ Poll an uplink,** 790 +))) 765 765 766 766 **Example**: 0x08FF, ask device to send an Uplink 767 767 ... ... @@ -771,9 +771,12 @@ 771 771 772 772 Use of trigger mode, please check [[ADDMOD6>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 773 773 774 -* (% style="color:#037691" %) **AT Command:**800 +* (% style="color:#037691" %)AT Command: 775 775 802 +(% class="box infomessage" %) 803 +((( 776 776 **AT+ADDMOD6=1 or 0** 805 +))) 777 777 778 778 1: Enable Trigger Mode 779 779 ... ... @@ -780,36 +780,43 @@ 780 780 0: Disable Trigger Mode 781 781 782 782 783 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x0A 06):**812 +* (% style="color:#037691" %)Downlink Payload (prefix 0x0A 06): 784 784 785 -**0x0A 06 aa ** ~/~/ Same as AT+ADDMOD6=aa 814 +(% class="box infomessage" %) 815 +((( 816 +**0x0A 06 aa ~/~/ Same as AT+ADDMOD6=aa,** 817 +))) 786 786 787 787 788 788 789 - 790 790 ==== 3.4.2.5 Poll trigger settings ==== 791 791 792 792 Poll trigger settings, 793 793 794 -* (% style="color:#037691" %) **AT Command:**825 +* (% style="color:#037691" %)AT Command: 795 795 796 796 There is no AT Command for this feature. 797 797 798 798 799 -* (% style="color:#037691" %) **Downlink Payload (prefix 0x AB 06):**830 +* (% style="color:#037691" %)Downlink Payload (prefix 0x AB 06): 800 800 801 -**0xAB 06 **~/~/ Poll trigger settings, device will uplink trigger settings once receive this command 832 +(% class="box infomessage" %) 833 +((( 834 +**0xAB 06 ~/~/ Poll trigger settings, device will uplink trigger settings once receive this command** 835 +))) 802 802 803 803 804 804 805 - 806 806 ==== 3.4.2.6 Enable / Disable DI1/DI2/DI3 as trigger ==== 807 807 808 808 Enable Disable DI1/DI2/DI2 as trigger, 809 809 810 -* (% style="color:#037691" %) **AT Command:**843 +* (% style="color:#037691" %)AT Command: 811 811 845 +(% class="box infomessage" %) 846 +((( 812 812 **Format: AT+DTRI=<DI1_TIRGGER_FlAG>,< DI2_TIRGGER_FlAG >** 848 +))) 813 813 814 814 815 815 **Example:** ... ... @@ -816,9 +816,9 @@ 816 816 817 817 AT+ DTRI =1,0 (Enable DI1 trigger / disable DI2 trigger) 818 818 819 -* (% style="color:#037691" %) **Downlink Payload (prefix 0xAA 02):**855 +* (% style="color:#037691" %)Downlink Payload (prefix 0xAA 02): 820 820 821 -**0xAA 02 aa bb 857 +**0xAA 02 aa bb **~/~/ Same as AT+DTRI=aa,bb 822 822 823 823 824 824 ... ... @@ -827,7 +827,7 @@ 827 827 828 828 Set DI1 or DI3(for LT-33222-L) trigger. 829 829 830 -* (% style="color:#037691" %) **AT Command:**866 +* (% style="color:#037691" %)AT Command: 831 831 832 832 **AT+TRIG1=a,b** 833 833 ... ... @@ -842,7 +842,7 @@ 842 842 843 843 844 844 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 01 ):** 845 -* **0x09 01 aa bb cc 881 +* **0x09 01 aa bb cc ** ~/~/ same as AT+TRIG1=aa,0x(bb cc) 846 846 847 847 848 848 ... ... @@ -868,7 +868,7 @@ 868 868 869 869 * (% style="color:#037691" %)**Downlink Payload (prefix 0x09 02 ):** 870 870 871 -**0x09 02 aa bb cc 907 +**0x09 02 aa bb cc **~/~/ same as AT+TRIG1=aa,0x(bb cc) 872 872 873 873 874 874 ... ... @@ -884,7 +884,7 @@ 884 884 885 885 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 01 )** 886 886 887 -**0x AA 01 aa bb cc dd ee ff gg hh 923 +**0x AA 01 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+ACLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 888 888 889 889 890 890 ... ... @@ -900,7 +900,7 @@ 900 900 901 901 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAA 00 )** 902 902 903 -**0x AA 00 aa bb cc dd ee ff gg hh 939 +**0x AA 00 aa bb cc dd ee ff gg hh ** ~/~/ same as AT+AVLIM See [[trigger mode>>||anchor="H3.3.6AT2BADDMOD3D6.28TriggerMode2COptional29"]] 904 904 905 905 906 906 ... ... @@ -907,16 +907,16 @@ 907 907 908 908 ==== 3.4.2.11 Trigger – Set minimum interval ==== 909 909 910 -Set AV and AC trigger minimum interval, system won 't response to the second trigger within this set time after the first trigger.946 +Set AV and AC trigger minimum interval, system won’t response to the second trigger within this set time after the first trigger. 911 911 912 912 * (% style="color:#037691" %)**AT Command** 913 913 914 -**AT+ATDC=5 **Device won't response the second trigger within 5 minute after the first trigger.950 +**AT+ATDC=5. Device won’t response the second trigger within 5 minute after the first trigger.** 915 915 916 916 917 917 * (% style="color:#037691" %)**Downlink Payload (prefix 0xAC )** 918 918 919 -**0x AC aa bb 955 +**0x AC aa bb ** ~/~/ same as AT+ATDC=0x(aa bb) . Unit (min) 920 920 921 921 922 922 ... ... @@ -931,6 +931,7 @@ 931 931 * (% style="color:#037691" %)**Downlink Payload (prefix 0x02)** 932 932 * **0x02 aa bb cc **~/~/ Set DO1/DO2/DO3 output 933 933 970 + 934 934 ((( 935 935 If payload = 0x02010001, while there is load between V+ and DOx, it means set DO1 to low, DO2 to high and DO3 to low. 936 936 ))) ... ... @@ -1107,7 +1107,7 @@ 1107 1107 1108 1108 * (% style="color:#037691" %)**AT Command:** 1109 1109 1110 -**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1147 +(% style="color:#037691" %)****(%%)**AT+VOLMAX ** ~/~/ See [[MOD4>>||anchor="H3.3.4AT2BMOD3D42CSingleDICounting2B1xVoltageCounting"]] 1111 1111 1112 1112 1113 1113 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA5):** ... ... @@ -1121,7 +1121,7 @@ 1121 1121 1122 1122 * (% style="color:#037691" %)**AT Command:** 1123 1123 1124 -**AT+SETCNT=aa,(bb cc dd ee) ** 1161 +(% style="color:#037691" %)****(%%)**AT+SETCNT=aa,(bb cc dd ee) ** 1125 1125 1126 1126 aa: 1: Set count1, 1127 1127 ... ... @@ -1145,7 +1145,7 @@ 1145 1145 1146 1146 * (% style="color:#037691" %)**AT Command:** 1147 1147 1148 -(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1185 +(% style="color:#037691" %)(%%)**AT+CLRCOUNT ** ~/~/ clear all counting 1149 1149 1150 1150 1151 1151 * (% style="color:#037691" %)**Downlink Payload (prefix 0xA6):**